Gebruiksaanwijzing /service van het product 31929E van de fabrikant Charles
Ga naar pagina of 14
Section 319–29E–202 Equipment Issue 2 Third Printing, June 1999 Charles Industries, Ltd. 1999 Charles Industries Ltd. CLEI is a trademark of Bell Communications Research, Inc. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice.
Section 319–29E–202 2 1. GENERAL 1.1 Document Purpose This document provides general, circuit, and testing information for the Charles Industries Span T ermination Sys- tem (STS) 3192–9E Powering T1 Network Interface Unit (NIU), shown in Figure 1.
Section 319-29E-202 3 2. APPLICA TION ENGINEERING The 3192–9E is ideally suited for use in provisioning T1 High Capacity Digital Service (HCDS) from lightwave-fed building Remote T erminals located at customer premise locations. See Figure 2 for a typical application.
Section 319–29E–202 4 The 3192–9E input current is highly dependent on application. Those applications that require the 3192–9E to power a customer ’s CSU will require a greater input current. T able 1 shows input current and heat release versus the equivalent series simplex resistance (at 60mA) present on the CI side of the unit.
Section 319-29E-202 5 + - 7.5 7.5 XMT LBO L OOPDOWN CONTROL MON RPT RCV MON RPT XMT DSX PREEQ SIGNAL REGEN L OS ALM LIGHTWAVE MUL TIPLEXER S3-1 DISABLE NETWORK SIGNAL DETECTOR NET LOS L OOPBACK COD.
Section 319–29E–202 6 S3 12 S4 DISABLE A I S S1 PWR 7.5 7.5 1 2 O N LP SC S2 LO S ALM R C V X M T R P T M O N R P T M O N WESCOM PWRG T1 NIU 3192-9E 91-31929E 0.6V ISS. 2 FA ESF NET LO S LB CI LO S MLB Figure 6. 3192–9E Front Panel Features and Options Location T able 2.
Section 319-29E-202 7 3.1 Signal T ransmission Paths In the idle (Looped down) mode, the signal from the network is coupled to the unit and routed through the trans- mit pad circuit. Switch S4 mounted on the circuit pack is used to adjust the transmit pad which consists of two cascaded 7.
Section 319–29E–202 8 3.5 T ransmit And Receive Signal Detectors The 3192–9E provides Monitoring Signal Detectors on the transmission paths. These detectors provide a mainte- nance aid for installation and troubleshooting.
Section 319-29E-202 9 4. INSPECTION Inspect the equipment thoroughly upon delivery . If the equipment has been damaged in transit, immediately re- port the extent of damage to the transportation company . Wescom equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment.
Section 319–29E–202 10 6.2 S2 — Front Panel MLB Push Button S2 is a recessed, front-panel push-button switch used to manually activate or deactivate loopback. Momentarily depress the MLB (Manual Loopback) push-button switch to activate or deactivate a loopback condition.
Section 319-29E-202 11 Step Action Action 8. Momentarily operate the 3192–9E front panel MLB pushbutton switch. The 3192–9E front panel LB LED should light indi- cating that the unit is in Loopback and the TBERD-209 should be receiving the looped back QRSS pattern.
Section 319–29E–202 12 8. TECHNICAL ASSIST ANCE 8.1 T echnical Assistance — U.S. If technical assistance is required, contact Charles Industries’ T echnical Services Center at: 847–806–8500 847–806–8556 (F AX) 800–607–8500 techserv@charlesindustries.
Section 319-29E-202 13 2. Include the following information: – Company name and address – Contact name and phone number – Inventory of equipment being shipped – Particulars as to the nature of the failure – Return shipping address 3.
Section 319–29E–202 14 (c) ESF DA T A LINK: The bit-oriented command and response message 0 001001 0 1 1111111 for 16 milli- seconds to loop up. The bit-oriented command and response message 0 010010 0 1 1111111 for 16 milliseconds to loop down. (d) LOOPBACK TIMEOUT : 20 Minutes 10.
Een belangrijk punt na aankoop van elk apparaat Charles 31929E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Charles 31929E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Charles 31929E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Charles 31929E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Charles 31929E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Charles 31929E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Charles 31929E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Charles 31929E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.