Gebruiksaanwijzing /service van het product 4E769B van de fabrikant Dayton
Ga naar pagina of 16
Operating Instructions & Parts Manual Dayton Pr opane Construction Heater Description Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater uses propane gas for combustion and electricity to run the motor. It is primarily intended for temporary heating of buildings under construction, alteration, or repair.
Dayton Operating Instructions and Parts Manual 2 Dayton Pr opane Construction Heater ® 4E769B General Safety Information Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 3 Model 4E769B Version B - For Reduction G016.J ® Specifications ELECTRICAL SPECIFICA TIONS Electrical Input Amperage 120 V olt/60Hertz 2 General Safety.
Dayton Operating Instructions and Parts Manual 4 Dayton Pr opane Construction Heater ® 4E769B Product Identification Figure 2 – Model 4E769B Shell Handle Motor Power Cord Hot Air Outlet (Front) Fan.
Dayton Operating Instructions and Parts Manual 5 Model 4E769B Version B - For Reduction G016.J ® A verage T emperature Number of T anks ( o F) at T ank Location (100 pound) 40 ° 1 32 ° 1 20 ° 1 10 ° 1 0 ° 1 -10 ° 2 -20 ° 2 Pr opane Supply Propane gas and propane tank(s) must to provided by the customer .
Dayton Operating Instructions and Parts Manual 6 Dayton Pr opane Construction Heater ® 4E769B Installation Review and understand the warnings in the General Safety Infor - mation Section. They are needed to safely operate this heater . Follow all local codes when using this heater .
Dayton Operating Instructions and Parts Manual 7 Model 4E769B Version B - For Reduction G016.J ® Operation (Continued) NOTE : If not opened slowly , excess-flow check valve on propane tank will stop gas flow . If this happens, close propane supply valve and open again slowly .
Dayton Operating Instructions and Parts Manual 8 Dayton Pr opane Construction Heater ® 4E769B Figure 11 - Removing Motor and Fan Guard from Heater Maintenance (Continued) SERVICE PROCEDURES Never attempt to service heater while it is connected to propane supply , operating, or hot.
Dayton Operating Instructions and Parts Manual 9 Model 4E769B Version B - For Reduction G016.J ® Ignitor Ignitor Mounting Screw Rear Head Figure 15 - Removing Ignitor Mounting Screw and Ignitor 7. Set gap between ignitor electrode and target plate to .
Dayton Operating Instructions and Parts Manual 10 Dayton Pr opane Construction Heater ® 4E769B 4E769B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide follow.
Dayton Operating Instructions and Parts Manual 11 Model 4E769B Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 4E769B Replacement Parts List Reference Number Description Part No.
Dayton Operating Instructions and Parts Manual 12 Dayton Pr opane Construction Heater ® 4E769B Never attempt to service heater while it is connected to propane supply , operating, or hot. Severe burns and electrical shock can occur . T roubleshooting Chart Symptom Possible Cause(s) Corrective Action 1.
Dayton Operating Instructions and Parts Manual 13 Model 4E769B Version B - For Reduction G016.J ® 4E769B Description Part No. 10' Rubber Hose with Brass Fitting LP A1020 U.L. listed. 15' Rubber Hose with Brass Fitting LP A1030 U.L. listed. Propane Gas Regulator LP A2110 U.
Dayton Operating Instructions and Parts Manual 14 Dayton Pr opane Construction Heater ® 4E769B Notes __________________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 15 Model 4E769B Version B - For Reduction G016.J ® 4E769B Notes ________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 16 Dayton Pr opane Construction Heater ® 4E769B 101427-01 Rev . B 01/00 Version B - For Reduction G016.J ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Natural gas construction heater, Models covered in this manual are warranted by Dayton Electric Mfg.
Een belangrijk punt na aankoop van elk apparaat Dayton 4E769B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dayton 4E769B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dayton 4E769B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dayton 4E769B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dayton 4E769B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dayton 4E769B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dayton 4E769B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dayton 4E769B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.