Gebruiksaanwijzing /service van het product 000 55 van de fabrikant Desa
Ga naar pagina of 16
100 SIDE FRONT HANDLES PFA/PV 003 PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL 150 SIDE FRONT HANDLE PFA/PV 007 Heater Sizes: 35,000 50,000 55,000 70,000 100,000 1 10,000 150,000 BTU/Hr ARL LOGO G 004 ® IMPORTANT Read and understand this manual before assembling, starting, or servicing heater.
2 099176 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ..........................................
3 099176 SAFETY INFORMA TION Continued W ARNINGS (Continued) • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
4 099176 PRODUCT IDENTIFICA TION 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Power Cord Side Cover Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Figure 1 .
5 099176 These models are furnished with wheels and a front handle. Some models are furnished with a rear handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton. Tools Needed • Medium Phillips Screwdriver • 3/8" Open or Adjustable Wrench • Hammer 1.
6 099176 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
7 099176 W ARNING ! VENTILA TION Continued Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
8 099176 OPERA TION Continued Item How Often How To Fuel tank Flush every 150-200 hours See Storage above. of operation or as needed. Air output and Replace every 500 hours of See Air Output, Air Intake, lint filters operation or once a year. and Lint Filters, page 10.
9 099176 Wrong pump pressure Dirty air output, air intake and lint filters Dirty fuel filter Dirt in nozzle Dirty photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time. W ARNING ! TROUBLE- SHOOTING Never service heater while it is plugged in, operating, or hot.
10 099176 SER VICE PROCEDURES Air Output Filter Lint Filter Air Intake Filter Filter End Cover Air Output Filter Lint Filter Air Intake Filter Filter End Cover Fan Guard Figure 11 - Air Output, Air In.
11 099176 Pump Pressure Adjustment 1. Remove pressure gauge plug from filter end cover. 2. Install accessory pressure gauge (part number HA1180). 3. Start heater (see Operation, page 7). Allow motor to reach full speed. 4. Adjust pressure. Turn relief valve to right to increase pressure.
12 099176 11. Tighten spark plug with spark plug mounting nut. 12. Release hex-body of spark plug from vise. 13. Replace burner strap onto combustion chamber. 14. Attach spark plug wire to spark plug. 15. Attach fuel and air line hoses to nozzle assembly.
13 099176 Nozzle (70/100/110/150,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 10). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench.
14 099176 (Pump Rotor, continued) 10. Install blades, pump plate, air filters, and filter end cover. 11. Replace fan guard and upper shell. 12. Adjust pump pressure (see page 11). Note: If rotor is still binding, proceed as follows. 13. Perform steps 1 through 6 (see page 13).
15 099176 MAINTENANCE KITS A 008 FLAME-OUT CONTROL/PHOTOCELL TESTER - HA1170 For all models. Special tool used to test the flame-out control and photocell. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applica- tions. Makes your heater even more portable and convenient.
W ARRANTY AND REP AIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship.
Een belangrijk punt na aankoop van elk apparaat Desa 000 55 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa 000 55 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa 000 55 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa 000 55 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa 000 55 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa 000 55 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa 000 55 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa 000 55 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.