Power Blower Operator's Manual MODELS PB-403H Serial Number 02001001 - 02999999 PB-403T Serial Number 02001001 - 02999999 W ARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood for proper and safe operation.
2 I NTRODUCTION Welcome to the ECHO family. This ECHO product was designed and manufactured to provide long life and on-the-job- dependability. Read and understand this manual. You will find it easy to use and full of helpful operating tips and SAFETY messages.
3 P OWER B LOWER O PERA TOR ' S M ANUAL IMPORTANT NOTE M ANUAL S AFETY S YMBOLS AND I MPORT ANT I NFORMA TION Throughout this manual and on the product itself, you will find safety alerts and helpful, information messages preceded by symbols or key words.
4 INTERNA TIONAL SYMBOLS S AFETY I NSTRUCTIONS PERSONAL CONDITION AND SAFETY EQUIPMENT W ARNING DANGER Power Blower users risk injury to themselves and others if the Power Blower is used improperly and/or safety precautions are not followed. Proper clothing and safety gear must be worn when operating a Power Blower.
5 P OWER B LOWER O PERA TOR ' S M ANUAL EXTENDED OPERA TION / EXTREME CONDITIONS V ibration and Cold It is believed that a condition called Raynaud’s Phenomenon, which affects the fingers of certain individuals may be brought about by exposure to vibration and cold.
6 SAFE OPERA TION W ARNING DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death. • Review area to be cleared. Look for potential hazards such as stones or metal objects.
7 P OWER B LOWER O PERA TOR ' S M ANUAL D ESCRIPTION PB-403H CONTENTS __ 1 - Power Head __ 1 - Flex Pipe __ 1 - Pipe w/swivel __ 1 - Straight Pipe __ 1 - Curved Pipe __ 1 - Operator's Manual.
8 1. SAFETY DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler.
9 P OWER B LOWER O PERA TOR ' S M ANUAL 1 2 3 7 10 11 12 13 14 15 5 6 4 PB-403T CONTENTS __ 1 - Power Head __ 1 - Flex Pipe __ 1 - Pipe w/swivel __ 1 - Straight Pipe __ 1 - Curved Pipe __ 1 - Ope.
10 1. SAFETY DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler.
11 P OWER B LOWER O PERA TOR ' S M ANUAL S PECIFICA TIONS MODEL ----------------------------------------------------- PB-403H, PB-403T Length ------------------------------------------------------- 320 mm (12.6 in.) Width -------------------------------------------------------- 460 mm (18.
12 A SSEMBL Y PB-403H W ARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLOWER PIPES / STICK HANDLE 1 . Assemble clamps (A) onto both ends of flexible pipe (B). 2 . Assemble straight pipe with swivel (C) into flexible pipe (B).
13 P OWER B LOWER O PERA TOR ' S M ANUAL PB-403T W ARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLOWER PIPES 1 . Assemble clamps (A) onto both ends of flexible pipe (B).
14 IMPORTANT Spilled fuel is a leading cause of hydrocarbon emissions. Some states may require the use of automatic fuel shut-off containers to reduce fuel spillage. Contact your ECHO dealer for ordering information. After Refueling • Wipe any spilled fuel from the unit.
15 P OWER B LOWER O PERA TOR ' S M ANUAL O PERA TION • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for starting. Do not allow the rope to snap back in. Always hold the unit firmly. • (PB-403H): Rotate spring loaded throttle arm downward to a comfort- able operating position.
16 ST ARTING W ARM ENGINE PB-403H 1. Throttle Lever Move throttle lever (A) to IDLE DETENT position. PB-403T 1. Throttle Lever/Stop Switch Move throttle lever (A) forward to idle position. Slide stop switch (B) forward to run position. PB-403H, PB-403T 2.
17 P OWER B LOWER O PERA TOR ' S M ANUAL OPERA TING BLOWER W ARNING DANGER Always wear safety glasses, hearing protection, a face filter mask and take all safety precautions or serious personal injury may result. Do not point the blower pipe in the direction of people or pets.
18 M AINTENANCE Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance.
19 P OWER B LOWER O PERA TOR ' S M ANUAL AIR FIL TER Level 1. Tools required: 25 - 50 mm (1 - 2 in.) medium bristle paint brush. Parts required: Tune Up Kit P/N 90070 NOTE Clean daily. 1 . Close choke (Cold Start Position). This prevents dirt from entering the carburetor throat when the air filter is removed.
20 SP ARK PLUG Level 1. Tools required: 3/4 in. Spark Plug deep socket, Feeler gauge (preferably a wire gauge) Parts Required: Tune Up Kit P/N 90070 1 . Remove spark plug , and check for fouling, worn and rounded center electrode. 2 . Clean the plug or replace with a new one.
21 P OWER B LOWER O PERA TOR ' S M ANUAL Cleaning Cylinder Fins 1 . Disconnect spark plug lead from spark plug. 2 . Remove engine cover (five screws), pull cover away from engine. 3 . Clean cylinder fins (A) to allow cooling air to pass freely. 4 .
22 CARBURETOR ADJUSTMENT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break-in period your engine performance will increase and exhaust emissions will stabilize.
23 P OWER B LOWER O PERA TOR ' S M ANUAL Initial Adjustment 1 . With engine off, turn HI speed screw (C) counterclockwise to stop. 2 . Turn LO speed screw (B) midway between stops. 3 . Turn idle screw (A) until tip of screw just touches throttle plate; then turn three (3) turns clockwise.
24 T ROUBLESHOOTING W ARNING DANGER Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark near an open spark plug opening, otherwise serious personal injury may result.
25 P OWER B LOWER O PERA TOR ' S M ANUAL 2 . Place the stop switch in the "STOP" position. 3 . Remove accumulation of grease, oil, dirt and debris from exterior of unit. 4 . Perform all periodic lubrication and services that are required.
26 NOTES.
27 P OWER B LOWER O PERA TOR ' S M ANUAL NOTES.
ECHO, INCORPORA TED 400 O AKWOOD R OAD L AKE Z URICH , IL 60047 www .echo-usa.com DEALER? Call 1-800-432-ECHO or www .echo-usa.com CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.
Een belangrijk punt na aankoop van elk apparaat Echo PB-403H (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Echo PB-403H heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Echo PB-403H vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Echo PB-403H leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Echo PB-403H krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Echo PB-403H bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Echo PB-403H kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Echo PB-403H . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.