Owner's Manuam POWER MISERTM ELECTRmC WATER HEATER FOR POTABLE WATER HEATING ONLY. NOT SUITABLE FOR SPACE HEATING, 9 MODEL NO. 153.329262 38 Gallon Short 153.329263 38 Gallon Short 153.329360 30 Gallon 152.329361 30 Gallon 153.329460 40 Gallon 153.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safetyore[ated messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater. Failure tofollow instructions and safety messages could result in death or serious injury. instruction manual must remain with water heater.
SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2 GENERAL SAFETY ...............................................................
Thank You for purchasing a Sears water heater. Properly instalbd and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact the local Sears Service Center or any Sears store.
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need al! of these materials, depending on your type of installation.
Removing the O_d Water Heater FIGURE 1. Q Turn "OFF" electrical supply to the water heater. FIGURE 2. Q Turn "OFF" the water to the water heater at the water supply shut-off valve or water meter. FIGURE 3. Q Attach a hose to the ,water heater drain valve and put the other end in a floor drain or outdoors.
_inerai Buildup or Sediment MayAccumuiate • This causes the water heater to become much heavier than normal. ,' IfspiNed, could cause staining. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.
Fire Hazard / Electric Shock Hazard ® Do not use this water heater with any voltage other than shown on the model rating plate. Failure to use the correct voltage shown on the model rating plate could result in death, serious bodily injury, or property damage Before making the conversion to 5500 watts, check the (1) power supply .
NOTE: To protect against untimely corrosion ofhot and cored water fittings, it is strongly recommended thatdioemectric unions or couplings be installed or} this water heater when connected tocopper pipe. Fit T &Pvalve insulation over valve. Make sure that the insulation does not interfere with the lever ofthe T & Pvalve.
Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances.
4. Check allnew water piping forleaks. Repair as needed. Converting the Lower E_ement These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to operate at 3800 watts.
LIFT OUT TAB TO UNCUP ?ERMBNAL COVER FROM THERr41OSTAT 8. Tighten terminals 2 and 3 to ensure proper electrical connection. Fire and Explosion Hazard • Failure to tighten screws can cause a fi re. o Failure to do this could result in death, serious bodily injury, or property damage, 5, 6, FIGURE 16.
11. Replace the access panel. FIGURE 21, 12. Complete wiring to the water heater, or if completed, turn "ON" electric power to the water heater after filling the tank with water. FIGURE 22, improper installation and use may result in property damage, • Fill tank with water before operation.
The length in any ground return path does not exceed 6 feet, The circuit conductors contained therein are protected by overcurrent devices rated at20 amperes or less, The conduit or tubing is terminat.
Wiring Diagrams STANDARD WIRING FOR 2 W{RE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT TO ELECTRIC POWER SUPPLY [ Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF".
Temperature Regulation Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before bathing or showering Temperature limiting valves are available.
NOTE: It is not necessary to adjust the upper thermostat. However, if it is adjusted above the factory set point of 120°F (49°C) HOT it is recommended that it not be set higher than the lower thermostat setting. The upper and lower thermostats are adjustable if a different water temperature is desired.
The water heater should be drained if being shut down during freezing temperatures. Also, periodic draining and cleaning of sediment from the tank may be necessary.
{ Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". Failure to do this could result in death, serious bodily injury, or property damage. 1. Before beginning turn "OFF" the electric power supply to the water heater.
8, g, Clean the area around the element opening, Remove any sediment from or around the element opening, inside the tank, If you are cleaning the element you have removed, do so by scraping or soaking.
18. Replace access panel, 19. Turn "ON" electric power to water heater, Drain Valve Washer Repmacement [ Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF".
Start Up Conditions TNERMAL EXPANSmON Property Damage Hazard ° Avoid water heater damage. o Install thermal expansion tank or device if necessary. o Contact qualified installer or service agency. NOTE: Expansion tanks are preocharged with a 40 psi air charge.
D.An excess ofactive hydrogen in the tank. This is caused by corrosion protective action ofthe anode. Smelly water may be eliminated or reduced in some water heater models by replacing the anode rod (s) with one ofless active material, and then chlorinating the water heater tank and al! hot water lines.
2_ 3. 4, 5. 6, 7, Make sure the electrica! supply to your water heater is "ON"_ Check for loose or blown fuses in your water heater circuit. Circuit breakers weaken with age and may not handle their rated load and should be replaced. Make certain the disconnect switch, if used, is in the 'ON" position.
Note: To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet,follow "Draining" instructions in the "Service and Maintenance'section and then remove fitting. Put pipe dope or teflon tape on the threads and replace.
KENMORE POWER MISER TM 9 ELECTRIC WATER HEATERS 153.329262 38 Gallon Short 153.329263 38 Gallon Short NOTE:A UPPER ELEMENT: These water heaters are equipped with 3800 watt elements LOWER ELEMENT: These water heaters are equipped with factory installed convertible elements, which can be operated at 3800 watts or 5500 watts.
KEN_tvIORE POWER MISER TM 9 ELECTRIC WATER HEATERS 153.329360 30 Gallon 153.32936! 30 Gallon 153.329460 40 Gallon 153.32946! 40 Gallon 153.329560 55 Gallon NOTE:A UPPER ELEMENT: These water heaters ar.
KENMORE POWER MISER TM 9 ELECTRIC WATER HEATERS 153.329561 55 Gallon 153.329660 66 Gallon 153.329661 66 Gallon 153.329860 80 Gallon 153.329861 80 Gallon NOTE:A UPPER ELEMENT: These water heaters are equipped with 3808 watt elements.
30.
31.
9 o YEAR LmMITEB WARRANTY ON WATER HEATER For nine years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner's manual instructions and al! Ioca! applicable plumbing codes, Sears will: 1.
Een belangrijk punt na aankoop van elk apparaat Kenmore 153.329861 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kenmore 153.329861 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kenmore 153.329861 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kenmore 153.329861 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kenmore 153.329861 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kenmore 153.329861 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kenmore 153.329861 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kenmore 153.329861 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.