Gebruiksaanwijzing /service van het product 186589-001 van de fabrikant State Water Heaters
Ga naar pagina of 32
PRINTED IN CANADA 0408 P AR T NO. 186589-001 REV . A KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
3 GENERAL SAFETY.
4 SAFE INST ALLA TION, USE AND SERVICE . . . . . . . . . . . . . 2 GENERAL SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 T ABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INTRODUCTION . . . . . .
5 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters insta lled in every dwelling, building or structure used in whole or in part.
6 GET TO KNOW YOUR W A TER HEA TER REPLACEMENT P ARTS Replacement parts may be ordered through authorized servicers or distributors. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired (as listed in Figure 1).
7 FIGURE 2 MIXING V AL VE USAGE This appliance has been design certi fi ed as complying with American National Standard/CSA Standard for water heaters and is considered suitable for: W ater (Potable) Heating and Space Heating: All models are considered suitable for water (potable) heating and space heat- ing.
8 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most eco- nomical use of the appliance.
9 INSULA TION BLANKETS Insulation blankets available to the general public for external use on gas water heaters are not necessary with this product. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters.
10 REQUIRED ABILITY INST ALLA TION OR SERVICE OF THIS W A TER HEA TER REQUIRES ABILITY EQUIV ALENT TO THA T OF A LICENSED TRADESMAN IN THE FIELD INVOL VED. PLUMBING, AIR SUPPL Y , VENTING AND GAS SUPPL Y ARE REQUIRED. INSPECT SHIPMENT There may be hidden damage caused in transit.
11 HOT W A TER OUTLET COLD W A TER INTLET DRAIN V AL VE DISCHARGE PIPE (DO NOT CAP OR PLUG) DRAIN P AN 3/4” SWEA T FITTING UNION SHUTOFF VA LV E FLOOR DRAIN 3/4” SWEA T FITTING TEMPERA TURE AND PRESSURE RELIEF V AL VE UNION 6” MAXIMUM AIR GAP FIGURE 5 Figure 5 shows the typical attachment of the water piping to the water heater .
12 distance below the structural fl oor . Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances.
13 minimum inlet gas pressure shown on the rating plate is that which will permit fi ring at rated input. All gas piping must comply with local codes and ordinances or with the National Fuel Gas Code ANSI Z223.1/NFP A 54 which- ever applies. Copper and brass tubing and fi ttings (except tin lined copper tubing) shall not be used.
14 SEDIMENT TRAPS A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fi tting with a capped nipple in the bottom outlet or other device recognized as an ef- fective sediment trap.
15 COMBUSTION AIR AND VENTILA TION When determining the installation location for a direct vent water heater , snow accumulation and drifting should be considered in areas where applicable.
16 DV TERMINA TION SAFETY COVER A Safey cover (see Figure 13) is available to prevent accidental contact with the vent terminal. Contact your Customer Service Department for ordering information.
17 ST ANDARD VENT ARRANGEMENT 2.6 in. (67mm) 3.6 in. (91mm) 2.1 in. (54.5mm) WALL 17 in. (432mm) MIN.,* 80 in. (2.03m) MAX. FIGURE 17 * If the horizontal distance is less than 30 in. (760mm), the restricter plate must be installed (see Figure 22). VENT ASSEMBL Y The vent tube and terminal can be assembled as shown in Figure 18.
18 FIGURE 23 Apply hi-temp red silicone (included) around the collar on air manifold box. Pull corrugated vent tube all the way on to collar and secure with one sheet metal screw (approx. 3/4 in. (19mm) up from edge of vent tube. Pull gear clamp past screw and tighten.
19 1 . T urn the t hermostat dial to lowest set ting (PIL OT LIG HTIN G ). 2. Push gas c ontrol kn ob down slightly and tur n clock-wi se to 'O FF' . D o not force. SEE FIG URE ' A' . T O TURN OFF GAS TO APPLIANCE 186271-000 1. STOP! Read the safet y information above on this label .
20 TEMPERA TURE REGULA TION TEMPERA TURE REGULA TION HOT W A TER CAN SCALD: W ater heaters are intended to produce hot water . Water heated to a temperature that will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact.
21 EXTERNAL DAMAGE Do not operate the water heater until it has been fully checked out by a quali fi ed technician, if the water heater: • Has been exposed to fi re or damage. • Displays evidence of sooting. • Produces steam or unusually hot water .
22 lines. Contact the local water heater supplier or service agency for further information concerning an Anode Replacement Kit and this chlorination treatment.
23 FOR YOUR SAFETY AND SA TISF ACTOR Y OPERA TION, IT IS RECOMMENDED THA T THIS HEA TER BE CHECKED ONCE A YEAR BY A COMPETENT SER VICE PERSON. USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME.
24 TEMPERA TURE & PRESSURE RELIEF V AL VE At least once a year , the temperature and pressure relief valve, Figure 1, must be checked to ensure that it is in operating condi- tion. Lift the lever at the top of the valve several times until the valve seats properly and operates freely .
25 Before removing the anode: 1) the tank water should be cool, 2) the cold water shut off valve must be closed, and 3) water pres- sure must be relieved by opening a nearby faucet. DRAIN V AL VE W ASHER REPLACEMENT (See Figure 29) 1. Turn “OFF” gas supply to water heater .
26 LEAKAGE CHECKPOINTS SERVICE If a condition persists or you are uncertain about the operation of the water heater contact a service agency . Use this guide to check a “Leaking” water heater . Many sus- pected “Leakers” are not leaking tanks.
27 TROUBLESHOOTING GUIDELINES PROBLEM POSSIBLE CA USE(S) CORRECTION BURNER WILL NOT IGNITE 1. Pilot not lit 2. Thermostat set too low 3. No gas 4. Dirt in the gas lines 5. Pilot line clogged 6. Main burner line clogged 7. Defective thermocouple 8. Defective gas control/thermostat 9.
28 PROBLEM POSSIBLE CA USE(S) CORRECTION SLOW HOT W A TER RECOV - ERY 1. Insuf fi cient secondary air 2. Flue clogged 3. Low gas pressure 4. Improper calibration 5. Gas control/thermostat set too low 6. Water heater too small 7. Wrong piping connections 8.
29 NOTES.
30 RESIDENTIAL GAS W ARRANTY THIS W ARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . In accordance with the warranty terms and conditions speci fi ed below .
31 SERVICE AND LABOR RESPONSIBILITY UNDER THIS LIMITED W ARRANTY , THE W ARRANTOR WILL PROVIDE ONL Y A REPLACEMENT W A TER HEA TER OR P ART THEREOF . THE OWNER IS RESPONSIBLE FOR ALL OTHER COSTS. Such costs may include but are not limited to: a. Labor charges for service, removal, or reinstallation of the water heater or part thereof.
32 500 TENNESSEE W AL TZ P ARKW A Y ASHLAND CITY , TN 37015 PHONE: 800-821-2017 F AX: 800-644-9306 www .statewaterheaters.com.
Een belangrijk punt na aankoop van elk apparaat State Water Heaters 186589-001 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen State Water Heaters 186589-001 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens State Water Heaters 186589-001 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding State Water Heaters 186589-001 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over State Water Heaters 186589-001 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van State Water Heaters 186589-001 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de State Water Heaters 186589-001 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met State Water Heaters 186589-001 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.