ADCP-90-216 Issue 2, January 1998 1017825 Page 1 © 1998, ADC Telecommunications, Inc. 7-Inch Fiber Distribution System Splice Module User Manual Content Page INTRODUCTIO N .......................................................................... . 1 Revision Histor y .
ADCP-90-216 Issue 2, January 1998 Page 2 1998, ADC Telecommunications, Inc. List of Changes PAGE IDENTIFIER DESCRIPTION OF CHANGE All pages – Reformat to current standards with editorial and technical changes.
ADCP-90-216 Issue 2, January 1998 Page 3 1998, ADC Telecommunications, Inc. 1. GENERAL 1.01 The AD C 7-Inch Fiber Distribut ion System ( FDS) ( Figure 1 ) pr ovides the te rminati on, splicing, and storage requirements of a large fiber optic cable system.
ADCP-90-216 Issue 2, January 1998 Page 4 1998, ADC Telecommunications, Inc. 3.03 Splice trays are available in nine configurations which provide splice chips to support individual splices.
ADCP-90-216 Issue 2, January 1998 Page 5 1998, ADC Telecommunications, Inc. 4. DESCRIPTION 4.01 The splice module requires a 7-inch (17.8 cm) mounting space withi n the frame. Major components of the splice module are shown in Figure 3 and are described in the following paragraphs.
ADCP-90-216 Issue 2, January 1998 Page 6 1998, ADC Telecommunications, Inc. Table 1. Splice Module Specifications FEATURE SPECIFICATION Dimensions Height 7 in.
ADCP-90-216 Issue 2, January 1998 Page 7 1998, ADC Telecommunications, Inc. C. Splic e Drawers 4.04 Th e splic e modul e contain s u p to six splice drawers.
ADCP-90-216 Issue 2, January 1998 Page 8 1998, ADC Telecommunications, Inc. 4. If applicable, remove the vertical cable guide from each side of th e frame position in which the splice module is being installed. 5. Place the splice module in its assigned position in the frame.
ADCP-90-216 Issue 2, January 1998 Page 9 1998, ADC Telecommunications, Inc. #12-24 SCREW (2 PLACES EACH SIDE) INTERBAY MANAGEMENT PANEL 1217-A VERTICAL CABLE GUIDE MOUNTING HOLES VERTICAL CABLE GUIDE MOUNTING HOLES VERTICAL CABLE GUIDE Figure 5. Vertical Cable Guide Installation in an Equipment Rack C.
ADCP-90-216 Issue 2, January 1998 Page 10 1998, ADC Telecommunications, Inc. Danger : Infrared radiation is invisible and can seriously damage th e retina of the eye. Do not look into the optical bulkhead of an operational transmitter, or into the launching (output ) end of an active fiber.
ADCP-90-216 Issue 2, January 1998 Page 11 1998, ADC Telecommunications, Inc. 5.07 One cable clamp kit is currently available. The OS P cable clamp kit accommodates cables with outside diameters that range from 0.5 to 0.8 inches (13-20 mm). 5.08 Select a grommet that when placed around the cable, has a gap o f nearly 0 to 0.
ADCP-90-216 Issue 2, January 1998 Page 12 1998, ADC Telecommunications, Inc. D. Fibe r Storage 5.11 Ope n the rear door about 2 inches (5 cm) and lift it from its hinges. Place the cover where it will not be scratched or damaged. 5.12 Route OSP/IFC fibers through a side access opening in the chassis to the assigned drawer of the splice module.
ADCP-90-216 Issue 2, January 1998 Page 13 1998, ADC Telecommunications, Inc. 6. SPLICING 6.01 Th e splice module accommodates most splicing methods which should be performed in accordanc e with local practices. The splice tray splice chip should be selected to match the local splice method.
ADCP-90-216 Issue 2, January 1998 Page 14 1998, ADC Telecommunications, Inc. 6.07 Coil the service loop clockwise (if the fiber entry is from the right) or counter-clockwise (if the fiber entry is from the left), around the radius limiters in the splice drawer.
ADCP-90-216 Issue 2, January 1998 Page 15 8. CUSTOMER SUPPORT SERVICES 8.01 ADC offers the follow ing customer support services. For calls originating in the U.S.A. or Canada, dial 1-800-366-3891 , then request the extension listed. For calls originating outside the U.
Een belangrijk punt na aankoop van elk apparaat ADC P-90-216 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ADC P-90-216 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ADC P-90-216 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ADC P-90-216 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ADC P-90-216 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ADC P-90-216 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ADC P-90-216 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ADC P-90-216 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.