Gebruiksaanwijzing /service van het product pm420 van de fabrikant Carver
Ga naar pagina of 20
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
Een belangrijk punt na aankoop van elk apparaat Carver pm420 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Carver pm420 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Carver pm420 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Carver pm420 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Carver pm420 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Carver pm420 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Carver pm420 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Carver pm420 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.