Models 1022/1024/1042 GARAGE DOOR OPENERS Includes INTELLICODE ® Remote Control Safe-T -Beam ® System must be installed to close door . For use only with sectional doors. Y our Residential Opener comes with a Rail Assembly which is standard for up to a 7 foot high door .
PN# 3642036534, 02/26/2010 REV . 1 2 OVER VIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMA TION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors.
PN# 3642036534, 02/26/2010 REV . 1 3 T ABLE OF CONTENTS OPENER FEA TURES INTELLICODE ® Rolling Code Security System. An electronic rolling code system that enhances the security of the door opener by continuously changing the access code each time the remote control is used.
PN# 3642036534, 02/26/2010 REV . 1 6 T o avoid damage to your door and/or opener , make sure you disable and/or remove any door locks, ropes, and/or cables (NOT door lif t cables) prior to inst alling your opener . ( Refer to Section 1.) 4 PRE-INST ALLA TION CHECK LIST FOR HELP-1.
PN# 3642036534, 02/26/2010 REV . 1 5 TYPICAL SECTIONAL DOOR INST ALLA TION FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM TYPICAL SUPPORT BRACKET (NOT PROVIDED) EXTENSION SPRING OR TORSION SPRING SAFE-T -BEAM ® BRACES ADDED HEADER BRACKET MOUNTING BOARD POWER CORD (APPROX.
PN# 3642036534, 02/26/2010 REV . 1 6 RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 3/16" Drill Bit 1/4", 7/16", 3/8" and 1/2" Sockets S tep ladder Drill.
PN# 3642036534, 02/26/2010 REV . 1 F ASTENERS - Shown Full size ( See Parts List below for full description.) Lag screw - 5/16" x 2" Self-drilling Screw 1/4"-20 x 3/4" Hex Flange N.
PN# 3642036534, 02/26/2010 REV . 1 8 1-PIECE RAIL HARDW ARE ASSEMBLED VIEW FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 3-PIECE RAIL HARDW ARE ASSEMBLED VIEW T ensioner Rail with chain Chain Cha.
PN# 3642036534, 02/26/2010 REV . 1 9 PENER ASSEMBL Y FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 1 NOTE: Three (3) piece rail assemblies are for a 7 foot high door . Clear a workspace area to unp ack and organize box and contents for assembly .
10 FIG . 1-2 Split Rail sections . FIG . 1-3 Split Rail assembly . A B Chain Rail Center Rail End Rail Wire Tie(s) Rail Assembly for CHAIN DRIVE OPENER NOTE: For split rail clamps, nuts, and bolts locate Bag 0 from Box 1. 3. Remove the two rail sections that are not connected to the chain and place them on floor (Fig.
POWER HEAD & RAIL ASSEMBL Y Assembly for CHAIN DRIVE OPENER NOTE: Handle carefully! Drive chain can slide out of rail. NOTE: For power head and rail assembly locate Bag 1 from Box 1. NOTE: Copy serial number from power head frame and record it on warranty page.
12 PN# 3642036534, 02/26/2010 REV . 1 FIG . 2-2 Finding highest point of travel . NST ALLA TION FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 2 HEADER AND DOOR MOUNTING BRACKETS: 1. Finding header bracket mounting location . • Close garage door .
MOUNTING THE OPENER: 1. Getting st arted . • Position assembled rail on wall next to header bracket (Fig. 2-4) . – Place material on floor under power head to protect from scratching. (A box, stool, or similar device may be needed to clear a torsion spring.
14 PN# 3642036534, 02/26/2010 REV . 1 DOOR BRACKET : NOTE: For door bracket and bolts locate Bag 4 from Box 2. 1. Finding door bracket mounting location . • Door bracket is mounted as high on door as possible along vertical centerline and NO LOWER THAN top set of rollers (Fig.
PN# 3642036534, 02/26/2010 REV . 1 NOTE: For Wall Console, wire and insulated staples locate Bags 6 and 7 from Box 2. 1. W all Console location. W all Console location should be in direct sight of door . It should be at least five feet (5') above floor to prevent small children from operating door .
PN# 3642036534, 02/26/2010 REV . 1 16 3.Securely fasten wires. Securely fasten wires to ceiling and wall using insulated staples provided. – Use insulated staples. – S taples should be snug only . If rear cover is attached to power head, remove it.
PN# 3642036534, 02/26/2010 REV . 1 17 AFE-T -BEAM ® SYSTEM INST ALLA TION FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 4 NOTE: The opener will not close the door automatically unless the Safe-T -Beam ® System is installed. NOTE: For Safe-T-Beam®, screws, wire, and insulated staples locate items and Bag 8 from Box 3.
PN# 3642036534, 02/26/2010 REV . 1 18 3b. Wiring (pre-wired) . Route wire from wall to Safe-T -Beam ® sensors (Fig. 4-5b) . S plice pre-wiring to shortened sensor wire, match wire pairs dash-to-dash and plain-to-plain . - T rim sensor wire to approximately one foot (1 ft) from sensor .
PN# 3642036534, 02/26/2010 REV . 1 19 ONNECTING TO POWER FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 5 Plug the opener into a properly grounded electrical outlet (Fig. 5-1). T o reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third ( grounding ) pin.
PN# 3642036534, 02/26/2010 REV . 1 20 OOR LIMITS FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 6 The OPEN (UP) and CLOSE (DOWN) door positions are controlled by making the adjustments on the panel located on the bottom of the power head.
21 Obtain st andard emergency release kit and remove S-hook from the cable end that attaches to the opener carriage. 1. Attach the emergency release cable loop end to the opener carriage as shown (FIG 6-4). Properly connecting the release cable to the carriage fitting will enable the correct carriage release action for the opener .
PN# 3642036534, 02/26/2010 REV . 1 22 FIG . 6-6 2 x 4 under center of door opening. CONT ACT REVERSE TEST The force adjustment s and limit switch settings MUST BE COMPLETED before testing. 1. T esting . Open garage door using wall button. – Place a 2" x 4" board (laid flat) under center of garage door opening (Fig.
PN# 3642036534, 02/26/2010 REV . 1 23 FCC and IC CER TIFIED FIG . 7-1 Learn code button and LED SET SET OPEN FORCE CL OSE C ODE LEARN LIMIT MANU AL Open T ravel Limit Open Set Limit Button Close T rav.
EMOTE CONTROL BA TTERY REPLACEMENT AND VISOR CLIP INST ALLA TION 8 FIG . 8-1 Open battery cover . 1. Battery replacement . • T o open gently push straight out on battery cover lock tab as shown (Fig. 8-1) . • Flip open battery cover . – Remove old battery .
PN# 3642036534, 02/26/2010 REV . 1 25 Use wall button supplied with opener . Any other wall control can cause the opener to operate unexpectedly . W ARNING If you have any questions, please do not hesitate to cont act Genie ® customer service at: 1.800.
PN# 3642036534, 02/26/2010 REV . 1 26 CIRCUIT WIRING DIAGRAM FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM 1 2 3 4 5 6 12 34 12 3 12 POWER CORD CORDON DE SECTEUR CABLE ELÉCTRICO TERMINAL BLOCK B.
PN# 3642036534, 02/26/2010 REV . 1 27 TROUBLESHOOTING GUIDE - OPERA TION FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM PROBLEM WHA T T O DO Opener does NOT run from W all Console. Check power source. – Plug a lamp into outlet used for power head.
PN# 3642036534, 02/26/2010 REV . 1 TROUBLESHOOTING GUIDE - POWER HEAD LED FOR HELP-1.800.354.3643 OR WWW .GENIECOMP ANY .COM Power head LED Possible Problem Solution Red LED showing Green LED showing .
PN# 3642036534, 02/26/2010 REV . 1 29 T ransmitters comply with all United S tates and Canadian legal requirements as of the date of manufacture. No warranty is made that they comply with all legal requirements of any other jurisdiction.
GMI Holdings, Inc d/b/a The Genie Company ("Seller") warrants to the original purchaser of the below identified opener Model 10 22 or opener Model 1024 or opener Model 1042 (“Product”), .
Een belangrijk punt na aankoop van elk apparaat Chamberlain 1042 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Chamberlain 1042 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Chamberlain 1042 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Chamberlain 1042 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Chamberlain 1042 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Chamberlain 1042 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Chamberlain 1042 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Chamberlain 1042 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.