Gebruiksaanwijzing /service van het product 3575S van de fabrikant Chamberlain
Ga naar pagina of 40
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1 196 www .liftmaster .com GARAGE DOOR OPENER Model 3575S For Residential Use Only Owner’ s Manual ■ Please read this manual and the enc losed safety materials carefully! ■ Fasten the man ual near the garage door after installation.
2 Introduction 2-5 Safety symbol and signal word review . . . . . . . . . . . . . . . 2 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3 T ools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Planning .
3 To prevent damage to garage door and opener: • ALWAYS disable locks BEFORE installing and operating the opener. • ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage. To prevent possible SERIOUS INJURY or DEATH: • ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance.
FINISHED CEILING Support bracket & fastening hardware is required. See page 12. Slack in chain tension is normal when garage door is closed. Safety Reversing Sensor Header Wa ll Access Door Safety.
5 Y our garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below . Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
W ashered Bolt 5/16"-18x1/2" Styrofoam T -rail Hole Lock Nut 6 ASSEMBL Y STEP 1 Attach the T -Rail to the Motor Unit T o av oid installation difficulties, do not run the gara g e door opener until instructed to do so. • Remove the bolt and lock nut from the top of the motor unit.
IMPOR T ANT INST ALLA TION INSTR UCTIONS 7 Lock W asher T o Tighten Outer Nut Inner Nut T rolley Chain Base of Rail 1/2" (13 mm) T o Tighten Inner Nut Outer Nut Mid Length of Rail INST ALLA TION ASSEMBL Y STEP 3 Tighten the Chain • Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley .
8 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door . 1. Close the door and mark the inside vertical centerline of the garage door .
9 INST ALLA TION STEP 2 Install the Header Bracket Y ou can attach the header bracket either to the wall above the garage door , or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket o ver drywall.
10 Clevis Pin 5/16"x2-3/4" Ring Fastener INST ALLA TION STEP 3 Attach the Rail to the Header Bracket • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NO TE: If the door spr ing is in the wa y you’ll need help .
11 ONE-PIECE DOOR WITHOUT TRA CK A 2x4 on its side is convenient for setting an ideal door-to- rail distance. • Remove foam packaging. • Raise the opener onto a stepladder .
12 Measure Distance Lag Screws 5/16"-18x1-7/8" Structural Supports Bracket (Not Provided) Lag Screws 5/16"-18x1-7/8" (Not Provided) Bolt 5/16"-18x7/8" Lock W asher 5/16&q.
13 INST ALLA TION STEP 6 Install the Door Control Locate door control within sight of door , at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided.
14 INST ALLA TION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install up to a 100 watt maximum light bulb in each socket.
15 INST ALLA TION STEP 9 Electrical Requirements T o av oid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
16 Invisible Light Beam Protection Area Safety Reversing Sensor 6" (15 cm) max. above floor Safety Reversing Sensor 6" (15 cm) max. above floor Facing the door fr om inside the garage INST A.
17 DOOR TRA CK MOUNT (RIGHT SIDE) Indicator Light Lens Lip Sensor Brack et Door T rack FLOOR MOUNT (RIGHT SIDE) W ALL MOUNT (RIGHT SIDE) Indicator Light Sensor Brack et Lens Extension Brack et (See Ac.
18 Invisible Light Beam Protection Area Safety Reversing Sensor Safety Reversing Sensor Connect Wire to Opener Quick-Connect T erminals Bell Wire Bell Wire Finished Ceiling Quick-Connect T erminals 3. T o release or insert wire, push in tab with screwdriver tip 1.
19 Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. INST ALLA TION STEP 11 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page.
20 Header Wall Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
21 INST ALLA TION STEP 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONL Y • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley .
22 ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
23 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
24 ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the right panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door . If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
25 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
IMPOR T ANT SAFETY INSTR UCTIONS Using Y our Garage Door Opener Y our Security ✚ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes.
27 Using the W all-Mounted Door Control THE SMART CONTR OL P ANEL™ Press the push bar to open or close the door . Press again to reverse the door during the closing cycle or to stop the door while it's opening.
Using the Remote Control NO TE: T o activate the remote control functions, pull out the plastic pull tab protruding from the remote control housing. This remote control is equipped with a proximity lighting feature. When moving a hand within close proximity to the remote control, the LED lights turn on for 3 seconds.
29 CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments.
30 HA VING A PROBLEM? 1. My door will not close and the light b ulbs blink on m y motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • V erify the safety sensors are properly installed, aligned and free of any obstructions.
Bell Wire Safety Reversing Sensor KG 1 3 9 7 5 KG 1 3 9 7 5 Diagnostics Located On Motor Unit LED or Diagnostic LED "Learn" Button 31 Installed Safety Reversing Sensor Y our garage door opener is programmed with self-diagnostic capabilities.
32 Meaning: This message will appear if the Safety Rever sing Sensors are out of alignment, if they are bloc ked or if the wiring is disconnected. T o c lear message from Smart Control P anel™ do the follo wing: • Check to see that area is clear between the Safety Reversing Sensors.
33 *3-Button Remotes (315 MHz) If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ 3 3-Button remote or compact remote can be programmed to operate other Security ✚ ® garage door openers.
KG 1 3 9 7 5 KG 1 3 9 7 5 1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds. 2. Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad.
35 1 3 4 5 6 2 REP AIR P ARTS Rail Assembly Parts KEY P ART NO . NO . DESCRIPTION 1 4A1008 Master link kit 2 41A4813 Chain pulley bracket 3 41A3489 Complete trolley assembly 4 1707LM One-piece rail for 7' (2.1 m) door 5 41D3484 Full chain assembly 6 83A1 1-2 Rail grease NO T SHO WN 1708LM One-piece rail for 8' (2.
36 Motor Unit Assembly Parts DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSY . Grey Wire Y ellow Wire (Up) Contact Center Limit Contact Drive Gear 2 4 3 1 15 19 8 17 5 18 9 10 16 14 13 12 6 6 11 7 7 7 7 KEY P ART NO .
37 ACCESSORIES CLOSED OPEN LOCK LIGHT 374LM 370LM 915LM 395LM 990LM 1702LM Outside Quick Release: Required for a garage with NO access door . Enables homeowner to open garage door manually from outside by disengaging trolley .
38 NOTES.
39 NOTES.
© 2008, The Chamberlain Group, Inc. 1 14A3615 All Rights Reserved LIFTMASTER ® SER VICE IS ON CALL OUR LARGE SER VICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SER VICE INFORMA TION IS AS NEAR AS Y OUR TELEPHONE. SIMPL Y DIAL OUR TOLL FREE NUMBER: 1-800-528-9131 www .
Een belangrijk punt na aankoop van elk apparaat Chamberlain 3575S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Chamberlain 3575S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Chamberlain 3575S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Chamberlain 3575S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Chamberlain 3575S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Chamberlain 3575S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Chamberlain 3575S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Chamberlain 3575S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.