T elephone entr y/access control sy s tem © 2010 The Chamberlain Group, Inc. All Rights Reser ved Ins t allation Manual for Ins t allation Manual for EL MODELS EL MODELS ® ® ® ®.
.
Table of Contents Page 1 Mounting the Unit Page Dimensions 2 EL25 Installation 3 Rotating the Keypad for Vertical Mounting 3 Unlocking/Locking EL2000 4 EL2000 Installation 5 Wire Type Wire Connections.
1-5/8 in. Conduit Hole Knockouts for 5/16 in. Knockouts f or 3/8 in. 15 in. AUG 10, 2005 WELCOME 3-1/16 in. 9 in. 1-5/8 in. 1-15/16 in. 2 in. 12 in. 7 in. 9-1/2 in. 6 in. 3-1/16 in. 1-1/2 in. 1/2 in. 6 in. 3-15/16 in. 3-1/16 in. 10-1/4 in. 3-1/16 in. 5-1/8 in.
Bracket Keypad Main Circuit Board Main Circuit Board Connections J200 - Speaker J402 - Light J404 - Call Button Board ONLY Vertical Mounting Position J401 - Keypad J406 - Light J201 - Microphone NOTE: Bracket notch lines up with ribbon cable on keypad.
Page 4 Unlocking/Locking EL2000 Unlocking EL2000 1. Apply pressure to the right-side of the unit. 2. While maintaining pressure, turn key clockwise. 3. Open cover. Locking EL2000 1. Turn key counter clockwise to lock position. 2. Close cover. 3. Apply pressure to left-side until you hear a “click” sound.
Page 5 # 1 2 3 ? 4 5 6 7 8 9 * 0 # # # # # # 1 2 3 4 5 6 7 8 9 0 * # ? # # # # # EL2000 Model Installation EL2000 Installation 1 Unlock Unit. 2 Open Cover. 3 Unplug the 2 Main Harnesses (Optional). 4 Slide Front Cover Out of Hinges (Optional). 6 Mount Back Housing to Wall or Pedestal.
Page 6 Wire Connections to the Unit Input Board Connections 1. Door 1 Exit Request and Door Status 2. Door 2 Exit Request and Door Status 3. Door 3 Exit Request and Door Status 4. Door 4 Exit Request and Door Status 5. Postal Lock Input 6. AutoCall Input 7.
Page 7 Wire Specs and Run Distances Wire Specs and Run Distances Use this chart to pull wires in preparation of your installation: Power Wire Specs and Run Distances Description of Wire Run Grounding .
Page 8 Grounding the Units Grounding the Units Ensure that the system is grounded properly. The units contain a number of static sensitive components that can be damaged by static discharge. IMPORTANT: An Earth Ground Rod is Strongly Recommended and should be no further than 12 feet from the unit and use a minimum of 12 gauge wire in most cases.
Page 9 Wiring 1 Unit to Telco Line Wiring 1 Unit to Telco Line The bypass board allows the unit to be disconnected without interrupting normal telephone operation. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 10 Wiring Multiple Units to Telco Line Wiring Multiple Units to Telco Line Up to 7 units can share the same phone line. The bypass boards allow the units to be disconnected without interrupting normal telephone operation.
Page 11 Wiring with No Telco Line Wiring with No Telco Line The unit can be a stand alone system that allows communication between the unit and a resident’s phones. Single Unit Tip Ring Tip Ring RES TELCO Use 18-24 AWG 2 twisted pair Output Board (See page 6) NOTE: Ringer Equivalence Number (REN) of “5” maximum.
Page 12 Wiring to Dedicated Telco Line Wiring to Dedicated Telco Line IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J.
Page 13 Wiring to an Internal Phone System Wiring to an Internal Phone System The units can be wired to any Analog Trunk in an internal home phone system. NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider.
Page 14 Connection To A NPBI System Connection To An NPBI System IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Tip.
Page 15 Wiring a Door Strike Lock/Maglock Wiring a Door Strike Lock Wiring a Maglock IO Output Board LED 2 LED 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 J3 J5 J4 J1 NO NC C NO NC C NO NC C NO NC C LED 4 LED 3 RES TELCO J6 J8 Use 18-22 AWG NOTE: The door strike can be connected to any of the 4 relays.
Page 16 Wiring a Gate Operator / Key Switch / PIR / REX Wiring a Gate Operator Wiring a Key Switch/PIR/REX Any auxiliary opening device such as a key switch or PIR (Passive Infrared Device), or an exit request button (REX) that provides normally open contact closure can be hooked up to the Door Input terminals.
Page 17 Wiring a Door Sensing Device / AutoCall Wiring a Door Sensing Device The units can monitor the position of up to four doors/gates and may react to a change in their status with one of the relays (not set as a control relay).
Page 18 Wiring a RF Module / Card Reader / Keypad Wiring a Radio Frequency Module An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information.
Page 19 Wiring a Postal Lock Switch / Internal Camera (CCTV) Wiring a Postal Lock Switch - EL25 Models Only The Post Office requires installation of a postal lock if postal carriers do not have access to a controlled area. Contact the local post office and arrange for them to install the postal lock while you are on site.
Page 20 Wiring Power to the Unit Wiring Power to the Unit The 110 VAC outlet must be dedicated to the unit ONLY . This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems: • Other equipment cannot introduce spikes, noise, surges or dips into the power circuit.
Page 21 J500 H2 100A UD H2 100A UD 3D2 100 16B J406 LCD J201 MIC J403 D2 D102 D153 3D2 100 16B 3D2 100 16B 3D2 100 16B H2 100A UD 3D2 100 16B J400 + DEVICE 1,2 Description Type Used on Model 1 11 10 9 8 7 6 5 4 3 2 No. Board Label EL25 EL2000 Name LED D300 X X PWR LED Indicates Unit is receiving power.
Page 22 Troubleshooting Troubleshooting Wiring • Check for correct length and AWG of wires. See page 7. • Check that wires are correctly inserted into the terminal blocks (not loose, no two sharing the same position). • Check board markings for correct terminal block placements.
Page 23 Repair Parts Repair Parts Installation and Service Information is Available Call our Toll Free Number 1-800-528-2806 www.chamberlain.com 17 21 22 18 19 20 16 15 10 13 14 11 11 12 8 9 7 4 5 6 1.
Page 24 EL2000 Parts Repair Parts Repair Parts 8 1 2 3 4 6 7 5 16 17 20 9 19 13 12 21 18 22 14 10 15 23 When ordering repair parts, please supply the following information: Description and Model Numbe.
Page 25 Your System Diagram Your System Diagram.
Page 26 Your Wiring Configuration Your Wiring Configuration External Access Control Device(s) connected to optional board(s) Device 0 __________________________________________________________________.
Page 27 Accessories Accessories 0 0 4 J 0 0 2 J 2 0 4 J 6 0 4 J 1 0 2 J 7 0 4 J 4 0 4J 1 0 4 J 6 0 4 J 4 0 4J 1 0 4 0 0 4 J N O C I T I N U W E N e h t k c i l C . 1 t i n U r e t n E d n a e m a N e p y T t i n U 1 , y r t n u o C r e t n E y t i C d n a .
Page 28 FCC and DOC Requirements FCC and DOC Requirements FCC Requirements The units comply with Part 68 of the FCC Rules. The label affixed to this equipment contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment.
.
® ® 845 L arch Avenue Elmhurs t, Illinois 60125-1196 114A4170B © 2010 The Chamberlain Group, Inc. All Rights Reser ved.
Een belangrijk punt na aankoop van elk apparaat Chamberlain EL25 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Chamberlain EL25 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Chamberlain EL25 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Chamberlain EL25 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Chamberlain EL25 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Chamberlain EL25 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Chamberlain EL25 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Chamberlain EL25 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.