Gebruiksaanwijzing /service van het product DX20i MkII van de fabrikant Charnwood
Ga naar pagina of 11
Operating and Installation Instructions CHARNWOOD DX20i MkII Multifuel Roomheater Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788.
GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions.
Open the main doors Open the ashpit door Close the ashpit door Close the main doors MULTIFUEL GRATE Your Charnwood is fitted with a multifuel grate which enables solid fuel, wood and peat to be burned equally effectively. The grate has two positions. One for solid fuel, the other for wood and peat.
For safety reasons, if the fire is to be left unattended with the doors open then use a spark guard which complies with BS 3248. ASH CLEARANCE The ashpan must be emptied regularly before it becomes too full. The most convenient time to remove the ash is just before riddling the fire since the ash will then be at it’s coolest.
THROAT PLATE AND FLUEWAY CLEANING It is important that the throat plate and all the appliance flueways are kept clean. When burning smokeless fuels they should be cleaned monthly. When burning other fuels they should be cleaned at least once a week, and more frequently if necessary.
Fire Blazing Out Of Control. Check that: a) the doors are tightly closed, b) the thermostat knob is turned down to the minimum setting, c) the air inlet damper is closed (at the bottom left of the app.
HEALTH AND SAFETY PRECAUTIONS WARNING Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin.
output sufficient for domestic hot water heating. If the boiler is fitted then the room heating will be reduced. The hot water system should be a gravity circuit and must be correctly vented as shown in Fig. 6. A double feed indirect hot water appliance.
same side as the boiler tappings. One of the original side firebricks is fitted on the other side, and the rear firebrick is discarded. The firebricks must be fire cemented into position, wetting the firebox will improve the adhesion. Replace the back fireplate, the side fireplates, the front firebar and the throat plate.
The free inset method of installation may be used instead of infilling. Details are available on request. THERMOSTAT Before lighting the fire check the cold setting distance of the thermostat. With the control knob at the minimum setting the flap should be just closed as shown in Fig.
1 5 0 º 5 0 6 2 6 5 4 0 5 1 2 0 2 6 0 2 0 0 5 4 7 i / d 4 0 0 2 6 0 1 5 0 8 4 6 0 4 6 2 0 O p t i o n a l B o il e r M a y B e F i tt e d W i t h T h e1 " B .
Een belangrijk punt na aankoop van elk apparaat Charnwood DX20i MkII (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Charnwood DX20i MkII heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Charnwood DX20i MkII vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Charnwood DX20i MkII leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Charnwood DX20i MkII krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Charnwood DX20i MkII bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Charnwood DX20i MkII kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Charnwood DX20i MkII . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.