Operating and Installation Instructions CHARNWOOD LA30iB Roomheater With Boiler Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 527552 Fax: (01983) 821267 E-Mail: charnwood@ajwells.
.
CHARNWOOD LA30iB Operating and Installation Instructions Contents Operating Instructions General Points ................................................... 3 Fuels ................................................................... 3 Door Operation ..
.
GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions.
anthracite, or homefire which should be burnt with the secondary air inlet open. RUNNING THE FIRE WITH THE DOORS OPEN The fire may be run with the doors open. This will result in a reduction in efficiency and hence heat output, particularly to the boiler.
brightly before filling with fuel. If the central heating pump is off overnight then the thermostat may be left at the same setting for both day and night operation. If the central heating pump is on overnight then set the thermostat control to give the required level of heating.
TROUBLE SHOOTING Fire Will Not Burn. Check that: a) the air inlet is not obstructed in any way, b) chimneys and flueways are clear, c) a suitable fuel is being used, d) there is an adequate air supply into the room, e) an extractor fan is not fitted in the same room as the fire.
HEA LTH AND SAFETY PRECAUTIONS Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash with plenty of water.
breast, one in the front to give access for infilling and fixing the flue pipe, and one in the side to give access for the pipework. CENTRAL HEATING SYSTEM The central heating system must comply with BS:5449 part 1.
with the centre-line of the chimney, and must also extend to the point where the chimney narrows to its final size. Any large voids must be filled and flaunched to the flue pipe to ensure that all soot deposits can be cleared when the appliance is swept.
ASSEMB LY Fit the side panels, hood and top grid onto the appliance. Instructions for this are enclosed with the panel pack. Replace any internal parts previously removed.
Boiler tappings are 1" B.S. P. female. Two each side. FLUE C L 154 i/d 200 120 506 265 405 164 59 235 235 619 554 394 547 150° Charnwood LA30iB Overall Dimensions (Dimensions are in mm) Page 11 LA30iB 3.
32 34 31 20 27 19 21 26 12 16 7 5 36 33 40 42 15 39 14 13 28 29 23 19 25 24 24 9 8 35 11 10 41 37 17 33a 30 18 38 45 46 47 48 49 26 012/FW14 Riddler Rod 27 012/CG05 Idler Rod 28 008/FW48 Thermostat C/W Flap 29 008/BW57 Thermostat Flap 90mm Dia 30 005/RW05 Side Panel L.
Een belangrijk punt na aankoop van elk apparaat Charnwood LA30iB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Charnwood LA30iB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Charnwood LA30iB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Charnwood LA30iB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Charnwood LA30iB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Charnwood LA30iB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Charnwood LA30iB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Charnwood LA30iB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.