Gebruiksaanwijzing /service van het product 4807 van de fabrikant Check Point
Ga naar pagina of 32
31 October 2011 Getting Started G uide Check Point 4000 Appliances Models: T-120, T-160 and T- 180.
© 2011 Check Point Software Technologies Ltd. All rights reserved. T his product and related d ocumentation are protect ed by copyright and distribut ed under licensing restricting th eir use, copying, distribut ion, and decom pilation.
Important Information Latest Software W e reco mmend that you install the most rec ent software release to st ay up - to -date with the latest functional improvem ents, stability fixes, security enhancem ents and protection aga inst new and evolving attack s.
W el come Safety, Environmental, and Electronic Emissions Notices Page 4 Safety, Environm ental, and Electronic Emissions Notic es Read the following warnings before s etting up or using the appli ance. Warning - Do not b lock air vents. A m inimum 1/2 -inch clearance is required.
W el come Safety, Environmental, and Electronic Emissions Notices Page 5 4. Circuit Overloading - Consideration sh ould be given to the co nnection of the equi pment to the suppl y circuit and the eff ect that overloading of the circ uits might have on over curr ent protection and sup ply wiring.
W el come Safety, Environmental, and Electronic Emissions Notices Page 6 Canadian Department Compliance Statement: This Class A digita l apparatus com plies with Canadian ICE S-003. Cet appareil numérique de la class e A est conforme à la norm e NMB-003 du Cana da.
Contents Important Infor mation ............................................................................................. 3 Safety , Environmental, and Elect ronic Emissions Notices .................................. 4 Introduction ...............
Page 8 Chapter 1 Introduction In This Chapter W elco me 8 Check Point 4000 Appliances Overview 8 Shipping Carton Co ntents 9 Term inology 9 Welcome Thank y ou for choos ing Check Point’ s C heck Point 4000 App liances. W e hope that you will be satisfied with this system and our s upport services.
Shipping Carton Contents Introduction Page 9 N ote - Screenshots in this guide ma y appl y only to the highest m odel to which this guide ap plies. Shipping Carton Contents This section desc ribes the contents of the shi pping carton.
Page 10 Chapter 2 Rack Mounting This chapter describes how to mount the appl iance in a rack . Important - T wo people are required to insta ll the appliance in a rac k in order to prevent any possible dam age.
Attaching the Ear Mount Brackets to the Appliance Rack Mounting Page 11 Attaching the Ear Mount Brackets to the Appliance Attach the two ear m ount brackets to the front of the appliance. Note - The ear m ount screws have 5 mm heads. To attach the ear mount brackets to the applia nce: 1.
Attaching the Appliance Rails to the Appliance Rack Mounting Page 12 Note - The app liance rail screws have 8 m m heads. To attach the ra il plates: 1. Attach a rail plate to an appliance rail us ing two appliance rail scre ws. 2. Do step 1 again for the other rail plate and ap pliance rail.
Installing the Appliance in the Rack Rack Mounting Page 13 2. Attach the appliance ra ils to the appliance using thre e appliance rail scr ews. 3. Do steps 1 and t wo again for the other s ide of the appliance. Installing the Appliance in the Rack Install the appliance i n the rack .
Page 14 Chapter 3 Configuring Check Point 4 000 Appliances The workf low for configuring Check Point 4 000 Appliances is: 1. Connect the cables an d power on the appliance. 2. Use the First T ime Configuration W izard to configure the appliance. 3. Add the Check Point 4000 Appliances object in Sm artDashboard a nd install a polic y.
Using the First Time Configuration Wizard Configuring Check Point 4000 Appliances Page 15 3. W ait for the appliance to initialize and boot. T he status of the appliance ap pears on the LCD scr een: The appliance is re ady for use when the m odel number is displa yed.
Using the First Time Configuration Wizard Configuring Check Point 4000 Appliances Page 16 Note - The f eatures configured in the wizard are accessible after completing the wizard via the W ebUI menu. The W ebUI menu can be accessed by navigating to https://<appliance_ip_address>:4434 .
Using the First Time Configuration Wizard Configuring Check Point 4000 Appliances Page 17 Management Type Set how the appliance is managed in the Managemen t Type page. Locally Managed Deplo yment : The appliance is a Security Gateway and a Security Managem ent server.
Creating the Network Object Configuring Check Point 4000 Appliances Page 18 Note - Do not use the Any va lue for security reasons. After you com plete the First Time Conf iguration W iz ard, m ore options are available using th e WebUI menu. SIC Setup Configure the SIC (Secure Internal Com munication) settings f or a Cent rally Managed appliance.
Page 19 Chapter 4 Check Point 4000 Appliances Hardware This chapter provides i nstructions for installing a nd removing hardware com ponents on Check Point 4000 Appliances.
Front Panel Components Check Point 4000 Appliances Hardware Page 20 Check Point 4600 Front Panel Item Description 1 Expansion line card s lot 2 Built in Ethernet ports (ET H1 - ET H7) 3 Management con.
Front Panel Components Check Point 4000 Appliances Hardware Page 21 Item Description 8 LCD display screen 9 Keypad Using the LCD Panel The appliance has an LCD panel that can be used to perform basic management operation s . You can select DHCP or configure the IP address, subnet n etmask, and default gatewa y of the managem ent interface.
Front Panel Components Check Point 4000 Appliances Hardware Page 22 To Press Approve the change when the cursor is located on the last digit Cancel the IP change when the cursor is located on the firs t digit Change current digi t or Configuring Management DHC P You can use the LCD panel to enable or disa ble DHCP on the m anagement interfac e.
Rear Panel Components Check Point 4000 Appliances Hardware Page 23 c) W hen th e panel shows t he correct IP address, m ove the cursor to the las t digit and press Enter . The panel shows Ne twork > Set M gmt IP . 6. Do steps 3 - 5 aga in for the subnet netm ask and the default gate way IP address.
Customer Replaceable Parts Check Point 4000 Appliances Hardware Page 24 Customer Replaceable Parts To ensure m aximum availability and ease of m aintenance, the Check Point 4000 Appliances cont ain th.
Customer Replaceable Parts Check Point 4000 Appliances Hardware Page 25 Removing the Po wer Supply This section desc ribes how to rem ove a power supply or place holder unit from a Check Point 4800 appliance. To remov e a power supply unit : 1. If the alarm sounds, press the red alarm button to the right of the po wer supply.
Customer Replaceable Parts Check Point 4000 Appliances Hardware Page 26 Installing Expan sion Line Cards To install an expansion line card : 1. Power off the applianc e and rem ove the power cords from the power supply units. 2. Loosen the retaining scr ews on the m etal cover on the front of the appl iance.
Page 27 Chapter 5 Restoring Fact ory Defaults As part of the troubles hooting process, it m ay be necessar y to restore the appliance to its factor y default settings.
Restoring Using the LCD Panel Restoring Factory Defaults Page 28 7. During the boot process , text sim ilar to that shown below appears: 8. At this point, you ha ve approximatel y four secon ds to hit any key to activate the Boot menu. 9. The Boot m enu opens.
Restoring Using the LCD Panel Restoring Factory Defaults Page 29 6. Once you have confir med the reset, wai t for the applia nce to restore the factor y image. While the appliance is restored t o the default im age, this message is continuousl y displayed: Reverting image don't turn off .
Page 30 Chapter 6 Registration and Support In This Chapter Registration 30 Support 30 W here To From Here? 30 Registration The appliance req uires a product- specific Check Point license. Obtain a license and register at the Check Point Appliance Reg istration site ( h ttp://register.
Page 31 Appendix A Compliance Information This appendix contai ns declaration of c onformity, compliance, and rel ated regulatory inform ation. In This Appendix Declaration of Conf ormit y 31 Declaration of Conformity Manufacturer’s Nam e: Check Point Soft ware Technologies Ltd.
Declaration of Conformity Compliance Information Page 32 EN61000-4- 2 Information Techno logy Equipment - Electrostatic Discharge Imm unity EN61000-4- 3 Information Techno logy Equipment - Radiated RF.
Een belangrijk punt na aankoop van elk apparaat Check Point 4807 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Check Point 4807 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Check Point 4807 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Check Point 4807 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Check Point 4807 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Check Point 4807 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Check Point 4807 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Check Point 4807 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.