Gebruiksaanwijzing /service van het product KEL-60-TSH van de fabrikant Cleveland Range
Ga naar pagina of 29
1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com SE95036 Rev .
Shut off pow er at main fuse disconnect prior to ser vicing. Ensure kettle is at room temperature and pressure gauge is showing z ero or less prior to removing any fittings . Inspect unit daily f or proper operation. 0 Do not fill kettle abo v e recommended le v el marked on outside of k ettle.
GENERAL Installation of the kettle must be accomplished by qualified electrical installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers.
RECOMMENDED FLOOR DRAIN DET AIL ASSEMBL Y Position the kettle in it's permanent location, and level the kettle by turning the adjustable flanged feet. Once positioned and leveled, permanently secure the kettle's flanged feet to the floor using 5/16" lag bolts and floor anchors (supplied by the installer).
INST ALLA TION CHECKS Although the kettle has been thoroughly tested before leaving the factory , the installer is responsible for ensuring the pr oper operation of kettle once installed. Visual Checks 1. Check Tilting (tilting kettles): A / Gearbox tilts kettle smoothly and freely .
OPERA TING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. On-Off Switch/Solid State T urns kettle ON/OFF and allows the operator to adjust the kettle T emperature Control temperature in incr ements from 1 (Min.) to 10 (Max.). (see T emperature Range Chart in the Operating Instructions section).
OPERA TING THE KETTLE DO NOT LEAN ON OR PLACE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED OVER, SPILLING HOT CONTENTS. 1. Before turning kettle on, read the V acuum/Pressure Gauge ( 4 ). The gauges needle should be in the green zone.
CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature).
ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust.
F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO. NO. 1. KE50825-5 3/4" Spout . . . . . . . . . . . . . . . . . . . . . .1 (KEL-25/30/40/60/80/100 & 40-SH) KE50825-3 3/4" Spout (KEL-25-T) . . . . . . . . . . . . .1 KE50825-2 3/4" Spout (KEL-40/60/80/100-T) .
HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P AR T NO . DESCRIPTION QTY . Hinge Assembly 1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-2 60 - 80 Gallon, 30 - 40 Gallon Full Jacketed .
ITEM NO. P ART NO. DESCRIPTION QTY . 1. KE50556-1 Probe, Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54941-5 Safety V alve, 50 PSI, 1/2" (Nor th America) . . . . . . . . . . . . .
11. KE000714-4 Pr essure Gauge, for units built prior to Februar y 2005 . . . . . . . . . . . . . . . . . . .1 KE50429-5 Pressure Gauge, for units built after January 2005 . . . . . . . . . . . . . . . . . . . . . .1 12. SE003013-1 L.E.D., Red, Replacement Kit.
CONTROL CONSOLE COMPONENTS - HAND TIL T 44 45 4 3.
CONTROL CONSOLE COMPONENTS - HAND TIL T ITEM NO. P ART NO. DESCRIPTION QTY . 1. F A11134 Screw , 10-24 x 3/8" SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. KE50325 Gear Box Lid . . . . . . . . . . .
CONTROL CONSOLE COMPONENTS - POWER TIL T 41 42 40 44 45 4 3.
CONTROL CONSOLE COMPONENTS - POWER TIL T ITEM NO. P ART NO. DESCRIPTION QTY . 1. KE503252 Gear Box Lid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A11134 Scr ew , 10-24 x 3/8" S.S.
TRUNNION ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO. NO. 1. KE00354 TRUNNION BEARING ASSEMBL Y . . . . . .1 (INCLUDES P ART # 3 & 6) 2. KE00351 TRUNNION BEARING ASSEMBL Y . . . . . .1 (INCLUDES P ART # 3 & 6) 3. KE51711 ROLLER BEARING . . . . .
SP ARE P AR TS LIST ITEM ON. DESCRIPTION QTY . QTY . DOMESTIC OVERSEAS Refer to Kettle Bottom & Side for p art s drawing KE00458 Solid State Control Box 1 1 KE50753-7 Relay , 12 VDC 1 KE50750-5 Contactor , 208/240V , 60 Amp.
Cleveland Range equipment requir es little preventative maintenance. W e do however provide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECK LIST The following check should be completed every six months or more frequently if unit is in a high volume facility .
CALIBRA TING PROCEDURE 1. Insure the unit has a vacuum befor e you begin calibrating procedur es. If unit requir es venting refer to Kettle V enting Instructions. 2. Set On-Off Switch/T emperature Contr ol to " 10 " ( Max.). 3. Allow the unit to cycle twice.
3. Pull Pressur e Relief V alve (A) open to insur e vessel is not pressurized. 4. Remove Pressur e Relief V alve (A). 5. Replace Pressur e Relief V alve (A) with Str eet Elbow (B). 6. Add distilled water (C) through the Str eet Elbow (B), using a funnel if necessary .
LUBRICA TION PROCEDURE Lubricate the following parts ever y three months to insure smooth operation and r educe wear . TRUNNION HOUSING , WORM SCREW AND TIL T GEAR These parts are accessed through the top cover of the console. Apply grease to gear teeth.
KETTLE JACKET CLEANOUT AND P ASSIV A TION PROCEDURES The following procedur e should be preformed at least once every three years to prevent possible corr osion and ensure the optimum life of the kettle. DESCRIPTION - Molyfilm 315 inhibits corrosion in stainless steel and copper .
Fault Isolation Pr ocedur e Step T est 1. Is there pr oper incoming voltage at terminal block? 2. Is the red LED illuminated? 3. Is the green LED illuminated? 4. Do both contactors energize? 5. Measure continuity acr oss safety thermostat. Is it an open circuit? 6.
Fault Isolation Pr ocedur e Step T est 1. In a cold state, does the pressur e gauge read in the gr een zone? 2. Do the contactors shut off too early? (before r eaching normal maximum operating pressur e.) 3. Does the green LED r emain illuminated after the contactors shut off? 4.
5. Remove kettle thermistor and allow to cool. Remove edge connector from control box. T est r esistance across edge connector's pins #2 and #7. Is it approximately 100,000 ohms? 6. T ur n the potentiometer on the control box clockwise to increase the maximum operating temperature.
WIRING DIAGRAM 200-240v OUTSIDE OF NORTH AMERICA LIMIT.
WIRING DIAGRAM 380-600v OUTSIDE OF NORTH AMERICA LIMIT.
Een belangrijk punt na aankoop van elk apparaat Cleveland Range KEL-60-TSH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cleveland Range KEL-60-TSH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cleveland Range KEL-60-TSH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cleveland Range KEL-60-TSH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cleveland Range KEL-60-TSH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cleveland Range KEL-60-TSH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cleveland Range KEL-60-TSH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cleveland Range KEL-60-TSH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.