4XLFN5H IHUHQF H*XLGH SCPI Co mmand Summa ry The following conventions are used for SCPI command syntax for remote interface programming: • Square brackets ( [ ] ) indicate o ptional keywords o r parameters. • Braces ( { } ) enclose parameter choices with in a command string.
Scan Measurement Commands ( see page 226 in the User’s Gu ide ) MEASure :TEMPerature? { TCoup le |RTD|FRTD|THERmi stor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < s.
Scan Configuration Commands ( see page 226 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger : SOU Rce {B U S | IMMediate |EXTernal|ALA Rm1|ALARm2|ALARm3|ALARm4 .
Scanning With an External Instrument ( see page 239 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXT ernal| TIMer } :SOURce? TRIGger .
Temperature Configuration Commands ( see page 219 in the User’s Gu ide ) CONFigure :TEMPerature { TCoupl e |RTD|FRTD|THERmis tor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,.
Voltage Configuration Commands ( see page 223 in the User’s Gu ide ) CONFigure :VOLTage:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONF.
Resistance Configuration Commands ( see page 224 in the User’s Gu ide ) CONFigure :RESistance [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) C.
Current Configuration Commands ( see page 224 in the User’s Gu ide ) Valid only on channels 21 and 22 on the 34901A mul tiplexer module. CONFigure :CURRent:DC [{< range >| AUTO |MIN|M AX|DEF} .
Frequency a nd Period Configuration Commands ( see page 214 in the User’s Gu ide ) CONFigure :FREQuency [{< range >| AUTO |MIN|MA X|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_li.
Mx+B Scalin g Commands ( see page 244 in the User’s Gu ide ) CALCulate :SCALe:GAIN < gain >[ ,( @ < ch_list >)] :SCALe:GAIN? [( @ < ch_list >)] :SCALe:OFFSet < offset >[,( @ .
Digital Input Commands ( see page 255 in the User’s Gu ide ) Ch 01 DIO (L SB) Ch 0 2 DIO (MSB ) Ch 03 Totalizer Ch 04 DAC Ch 05 DAC CONFigure:DIGital:BYTE ( @ < scan_list >) CONFigure? [( @ &l.
Switch Control Commands ( see page 259 in the User’s Gu ide ) ROUTe :CLOSe ( @ < ch_list >) :CLOSe:EXCLusive ( @ < ch_list >) :CLOSe? ( @ < ch_lis t >) ROUTe :OPEN ( @ < ch_list.
System-Related Commands ( see page 264 in the User’s Gu ide ) SYSTem :DATE < yyyy > , < mm > ,< dd > :DATE? :TIME < hh >,< mm >,< ss.
Status System Commands ( see page 286 in the User’s Gu ide ) *STB? *SRE < enable _value > *SRE? STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]? :QUEStionable:ENABle < ena ble_value &.
Service-Related Commands ( see page 294 in the User’s Gu ide ) INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CLEar (1|2|3} DIAGnostic :RELay:CYCLes? [( @ < ch_list >)] :RELay:CYCLes:CLEar [( @ < ch_list >)] *RST SYSTem:PRESet SYSTem:CPON {100|200|300|ALL } SYSTem:VERSion? *TST? IEEE 488.
Agilent 34901A 20-Channel Multiplexer ( see page 164 in the User’s Gu ide ) Agilent 34902A 16-Channel Multiplexer ( see page 166 in the User’s Gu ide ) 16.
Agilent 34903A 20-Channel Act uator ( see page 168 in the User’s Gu ide ) Agilent 34904A 4x8 Matrix ( see page 170 in the User’s Gu ide ) 17.
Agilent 34905A/6A Dual 4- Channel RF Multiplexers ( see page 172 in the User’s Gu ide ) Agilent 34908A 40-Channel Single-Ended Mul tiplexer ( see page 174 in the User’s Gu ide ) 18.
Agilent 34907A Mult ifunction Module ( see page 176 in the User’s Gu ide ) 19.
Factory Reset State The table below shows the state of the instrument after a FACTORY RESET from the Sto/Rcl menu or *RST command from the remote interface.
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies 34970A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies 34970A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies 34970A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies 34970A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies 34970A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies 34970A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies 34970A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies 34970A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.