How your 3499A/B/C T est System Benefits From Upgrading to the New 34980A Switch/Measure/Control System Application Note This application not e will describe differences and advant ages of t he new 34980A as compared to the 3499A/B/C.
2 List of 34980A Measurement Capabilities • T emperature measured with Thermocouples, RTDs and Thermistors • DC and AC volts • 2- and 4-wire Resistance • Frequency and Period • DC and AC cur.
3 Modules The 34980A implements a superior selection of switch topologies. The 34980A swit ch topologies are similar t o 3499A/B/C switch modules and include multiplex ers, matrixes, high-po w er , general purpose, and RF/micro wav e switches.
4 Module T ype 34980A 3499A/B/C Multiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A 34922A 70 Ch armature 300V 1A N2266A 40 Ch reed 200V .5A 34923A 40 Ch reed 200V .5A N2270A 10 Ch 1000V 1A 34924A 70 Ch reed 80V .5 44470A 10 Ch armature 250V 2A 34925A 40 Ch FET +/-80V .
5 User Interface The 34980A of fers the most modern instr ument I/O options for inter facing a controller PC wit h the switch system: GPIB, USB and L AN. All three Input/Output inter face connections come standard with the 34980A mainframe. If you choose t o modify or upgrade your test system I/O, the 34980A is system ready.
6 W eb Page Interface The 34980A comes wit h a built-in detailed instr ument w eb page that allo ws you t o remot ely connect and communicate with the mainframe and installed modules. Y ou establish a L AN connection, eit her directly between t he 34980A and PC, or from the 34980A to an existing Local Area Netw ork.
7 T able 4. Command comparisons 34980A 3499A/B/C Close channel 10 on the module in slot 3 ROUT e:CLOS (@3010) [ROUT e:]CLOS (@310) Scan channels 0 through 40 on the module in slot 1 ROUT e:SCAN (@1001:1040) [ROUT e:]SCAN (@100:140) and channel(s) rat her than only three digits as the 3499A/B/C uses.
8 Scan Feature The scan feature is a sequence of alternating swit ch closures and measurements. This feature is pro vided by bot h the 34980A and a 3499A/B/C combined wit h a DMM or ot her measurement instrument.
9 Monitor Feature The 34980A monit or feature allo ws you t o monit or readings acquired by the switch/measure system. Y ou can also monitor readings acquired wit h t he 34980A internal DMM.
10 Switch and Measurement Connections Most often, t est syst ems must be f lexible enough to be easily mov ed to a new location or modified for different devices under test. Having a remo vable wiring ter minal block or a pre-wired cable is optimal in t hese situations.
11 Summary Although the 3499A/B/C Switch/Control system has been a great addition to many test systems, the new 34980A now offers an even better module selection plus measurement capability , standard PC connections f or communication, and is easy to connect to modules.
12 Appendix A – Command Reference/Comparison 34980A Commands ABORt CALCulate :A VERage:AVERage? :A VERage:CLEar :A VERage:COUNt? :A VERage: MAXimum? :A VERage:MAXimum:TIME? :A VERage:MINimum? :A VER.
13 :CURRent:AC :CURRent[:DC] :DIGital:ST A T e :DIGital:WIDTh :FREQuency :FRESistance :PERiod :RESistance :TEMPerature :TOT alize [:VOL T age]:AC [:VOL T age][:DC] CONFigure? DA T A :LAST? :POINts:EVE.
14 :CURRent:AC? :CURRent[:DC]? :DIGital[:<width>]? :DIGital[:BYTE]:BIT? :FREQuency? FRESistance? :PERiod? :RESistance? :TEMPerature? :TOT alize? [:VOL T age]:AC? [:VOL T age][:DC]? MEMory :ST A .
15 :SCAN :SCAN:ADD :SCAN:REMove :SCAN:SIZE? SAMPle :COUNt :COUNt? SENSe :CURRent:AC :BANDwidth :BANDwidth? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :CURRent[:DC] :APERture:ENABled? :APERture :NPLC :NPL.
16 :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :FUNCtion :FUNCtion? :PERiod:APERture :PERiod:VOL T age:RANGe :VOL T age:RANGe? :VOL T age:RANGe:AUTO :VOL T age:RANGe:AUTO? :PERiod:ZERO:AUTO :RESi.
17 [:DC]:NPLC? [:DC]:RANGe [:DC]:RANGe? [:DC]:RANGe:AUTO [:DC]:RANGe:AUTO? [:DC]:RESolution [:DC]RESolution [:DC]:ZERO:AUTO [:DC]:ZERO:AUTO? SOURce :CURRent[:LEV el] :CURRent[:LEV el]? :DIGital:DA T A.
18 :ALARm:ENABle? :ALARm[:EVENt]? :MODule:ENABle :MODule:EVENt? :MODule:SLOT[n]:CONDition? :MODule:SLOT[n]:ENABle :MODule:SLOT[n][:EVENt]? :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :O.
19 :TIME? :TIME:SCAN? :VERSion? TRACe:CA T alog? [:DA T A] [:DA T A]:DAC [:DA T A]:FUNCtion :DELete:ALL :DELete[:NAME] :FREE? :POINts? TRIGger :COUnt :COUNt? :DELay :DELay? :DELay:AUTO :DELay:AUTO? :SOURce :SOURce? :TIMer :TIMer? UNIT :TEMPerature :TEMPerature? IEEE-488.
Agilent T echnologies ’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need.
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies 34980A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies 34980A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies 34980A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies 34980A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies 34980A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies 34980A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies 34980A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies 34980A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.