Gebruiksaanwijzing /service van het product 629088480 van de fabrikant Cornelius
Ga naar pagina of 10
Thermostat Reset Upgrade Kit Installation Instructions © 2005, IMI Cornelius Inc. - 1 - Publication Number: 629088480INS INSTALLATION INSTRUCTIONS FCB Pinnacle 2 Flavor Emerson Units T H E R M O S T A T R E SE T U P G R AD E K I T P/N 629088480 IMPORTANT: This procedure is intended for use by a Qualified Service Technician.
Thermostat Reset Upgrade Kit Installation Instructions Publication Number: 629088480INS - 2 - © 2005, IMI Cornelius Inc. Installation Instructions 1. Pull Pinnacle away from wall. DISCONNECT POWER FROM THE UNIT. Remove lower back panel. 2. Remove the 4 screws holding contactor box cover (bottom rear of unit).
Thermostat Reset Upgrade Kit Installation Instructions © 2005, IMI Cornelius Inc. - 3 - Publication Number: 629088480INS 4. Remove thermostat wires from their connections. Feed the wires out of the contactor box. Discard the black jumper wire. 5. Feed the white wires that originate from the safety circuit box out of the contactor box.
Thermostat Reset Upgrade Kit Installation Instructions Publication Number: 629088480INS - 4 - © 2005, IMI Cornelius Inc. 8. Place hole template at lower left of back of frame. The dot sticker should be at the lower left of template. Line up edge of hole template to edge of frame, as shown, and clamp in place.
Thermostat Reset Upgrade Kit Installation Instructions © 2005, IMI Cornelius Inc. - 5 - Publication Number: 629088480INS 14. Remove contactor from box and connect main power and contactor harnesses, as shown. IMPORTANT – Main power MUST be on same side as flag terminals already attached to contactor (see photo).
Thermostat Reset Upgrade Kit Installation Instructions Publication Number: 629088480INS - 6 - © 2005, IMI Cornelius Inc. 16. Disconnect terminals bridging the two thermostats (see photo). Remove wire tie, if present. 17. Take the wires from the safety circuit and connect them to the thermostats.
Thermostat Reset Upgrade Kit Installation Instructions © 2005, IMI Cornelius Inc. - 7 - Publication Number: 629088480INS 20. Place the stainless steel lock-washer over the brass screw and thread it in (a “screw starter” screwdriver makes this much easier).
Thermostat Reset Upgrade Kit Installation Instructions Publication Number: 629088480INS - 8 - © 2005, IMI Cornelius Inc. 25. Set three ground wires (1 from contactor box, 1 from main power, and 1 from safety box) in place and tighten screw (see photo).
Thermostat Reset Upgrade Kit Installation Instructions © 2005, IMI Cornelius Inc. - 9 - Publication Number: 629088480INS 29. Make sure all wires are in the safety circuit box, hold box in place against the frame, and drive 4 short thread-cutting screws (included in kit) through safety circuit box into frame.
Thermostat Reset Upgrade Kit Installation Instructions Publication Number: 629088480INS - 10 - © 2005, IMI Cornelius Inc. 32. Pull the Brown wire labeled “P4” from its location on the Emerson Inverter Board 33. Place the female terminal of the In-Rush Protection harness on the terminal that you just removed the brown wire from.
Een belangrijk punt na aankoop van elk apparaat Cornelius 629088480 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cornelius 629088480 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cornelius 629088480 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cornelius 629088480 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cornelius 629088480 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cornelius 629088480 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cornelius 629088480 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cornelius 629088480 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.