Gebruiksaanwijzing /service van het product ED-250 BCP van de fabrikant Cornelius
Ga naar pagina of 16
Installation Manual ENDURO ICE/BEVERAGE DISPENSER Model: ED-250 BCP IMPORT ANT : TO THE INST ALLER. It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A1 12.
i 620916501INS T ABLE OF CONTENTS Page SAFETY PRECAUTIONS 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESCRIPTION 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 620916501INS REMOV ABLE STRA W HOLDER P ANEL LID/STRA W HOLDER BEVERAGE F AUCET ON/OFF SWITCH ICE PORTION CONTROL MODULE MANUAL/AUTO ICE TOGGLE SWITCH MANUAL ICE DISPENSE RED PUSH BUTTON SWITCH DRIP TRA Y CUP REST LOWER ACCESS P ANEL BEVERAGE F AUCETS (8) ICE AGIT A TOR RET AINER ICE BIN COVER FIGURE 1.
2 620916501INS SAFETY PRECAUTIONS Always: Disconnect power to the dispenser before servicing or cleaning. Never : Place hands inside of hopper or gate area without disconnecting power to the dispenser .
3 620916501INS INST ALLA TION INSTRUCTIONS 1. Locate the dispenser indoors on a level counter top. The ice dispenser must be sealed to the counter . The MOUNTING TEMPLA TE (see Figure 3) indicates where openings can be cut in the counter .
4 620916501INS DRAIN LINE 1-IN. I.D. PLASTIC TUBING (6 FT) WITH INSULA TION SOL VENT BOND HOSE CLAMP BARB ADAPTER 1 BARB X 3/4 MPT COUPLING 3/4 SOCKET X 3/4 FPT DRIP TRA Y DRAIN FITTING FIGURE 2.
5 620916501INS 12 OPENING 30 23 21–1/4 29 9–3/16 1 1–5/8 18–5/8 1–5/16 1–13/16 26–7/16 7/16 30–1 1/16 21–1/4 23–1/16 RECOMMENDED COUNTER OPENING SIZE 9.00 X 12.00 FOR UTILITIES AND BEVERAGE TUBING. OPENING CAN BE LOCA TED ANYWHERE WITHIN THE SHADED AREA.
6 620916501INS S3 INST ALL FOR NON–CARB AS REQUIRED S6 S3 CHECK VA LV E OPTIONAL FOR DIET DRINKS OR ROOT BEER S8 SYRUP T ANKS 15–50 PSIG S1 S7 S6 PRESSURE REGULA TORS S2 S4 S5 S6 S7 S8 S7 S5 S1 S2.
7 620916501INS ICE GA TE CYLINDER REVERSE SINGLE ACTING-SPRING EXTENDED PNEUMA TIC GA TE SOLENOID V AL VE 3-W A Y NORMALL Y CLOSED FIL TER–REGULA TOR (F ACTOR Y -SET OUTLET PRESSURE TO 32-36 PSIG) MANUAL OVERIDE SOLENOID V AL VE 3-W A Y NORMALL Y CLOSED CO2 SUPPL Y 50 PSIG MAX.
8 620916501INS FEMALE HARNESS CONNECTOR MALE HARNESS CONNECTOR GROUND SPLICE/QUICK CONNECT CONNECTION LEGEND GEN/YEL GREEN W/YELLOW STRIP GRN GREEN RED RED BLU BLUE VIO VIOLET BRN BROWN ORN ORANGE YEL YELLOW WHT WHITE BLK BLACK WIRE COLOR CHART 620913001 REV .
9 620916501INS FIGURE 7. WIRING SCHEMA TIC (1 15 VOL T) 120V INTERLOCK RELA Y MANUAL ICE DISPENSE SWITCH MANUAL/AUT O ICE T OGGLE SWITCH ICE CHUTE INTERLOCk SWITCH BEV ON/OFF SWITCH 24V AC AGIT A TOR RELA Y PORTION CONTROLLER/ T OUCH P ANEL T OUCH P ANEL BEV V AL.
10 620916501INS THIS P AGE LEFT BLANK INTENTIONALL Y.
11 620916501INS W ARNING: If repairs are to be made to the beverage system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO 2 system, stop dispensing, shut off the CO 2 supply , then relieve the system pressure before proceeding.
12 620916501INS T rouble Remedy Probable Cause NO ICE DISPENSED FROM ICE PORTION CONTROLLER ICE PORTION CONTROLLER (CONTINUED) D. Insufficient or no CO 2 supply to dispenser . D. Restore CO 2 supply to dispenser . E. Ice chute cover not properly Installed.
13 620916501INS W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country , please write, fax or telephone the IMI Cornelius office nearest you.
IMI CORNELIUS INC..
Een belangrijk punt na aankoop van elk apparaat Cornelius ED-250 BCP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cornelius ED-250 BCP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cornelius ED-250 BCP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cornelius ED-250 BCP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cornelius ED-250 BCP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cornelius ED-250 BCP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cornelius ED-250 BCP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cornelius ED-250 BCP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.