Gebruiksaanwijzing /service van het product 8510C van de fabrikant Agilent Technologies
Ga naar pagina of 16
The Agilent Technologies 8510C is a modular family of com patible products. F or f lexibility in specifying a solution that meets your exact needs, a system is typically ordered as separate line items. For those who wish ordering conv enience, complete bundled systems are available.
2 Agilent E7350A single-connection single-sweep network analyzer system (2 to 110 GHz) The E7350A is a complete system configured wit h an 8510C, a 20 GHz and 50 GHz synthesizer , tw o 110 GHz S-parameter test heads, and a millimet er test set controller .
3 Agilent 8510SX network analyzer system (45 MHz to 26.5 GHz) The 8510SX is a complete system configured wit h a 26.5 GHz synthesizer , 26.5 GHz S-parameter test set, and a complete set of 3.
4 Agilent 85108A pulsed-RF network analyzer system (2 GHz to 20 GHz) Based on an 8510C with Option 008, t his system pro vides the capability to measure t he am plitude and phase response of a device or com ponent being driven with a pulsed-RF input signal.
5 System components F or f lexibility in specifying a solution that meets your exact needs, a system can be or dered as sepa- rate line items. A complete system includes t he Agilent 8510C network anal yzer , a t est set, com pat- ible source, and measurement accessories.
6 Millimeter- wave test sets and controllers Banded waveguide millimeter-wave subsystem (Com ponents of 85106D) • 85105A millimeter-wave test set controller Requires addition of tw o 85104A series modules for com plete wav eguide S-parameter test set operation.
7 Common options for RF sources Option Description 908 Add rack flange kit 910 Extra operating and service manual 913 Add rack flange and handles kit Ext ended service options are available.
8 Calibration kits Err or correction requires t hat the systematic errors in the measurement system be charact erized by measuring kno wn devices (st andards) o v er the frequency range of interest with t he process of cal- ibration. All calibration kits contain st andards used for this purpose.
9 V erification kits V erif ication kits are used to verify the performance specifications of an A gilent 8510 system. All kits include a precision Z o airline, mismatched airline, and fixed attenuators. Measured dat a and uncer- tainties traceable t o the U.
10 Configuration B . This cable arrangement is for appli- cations where the device under test is connected between cable ends. This setup off ers more f lexibil- ity when connecting to the device under test. For Agilent 8514B/8515A/85110A test sets (3.
11 T est configuration accessories Power meter and power sensors • E4418A power meter and 8480 series power sensors Required for use with test port pow er f latness correction feature. Bias supply • 6626A precision DC power supply F or connection to 851XA test set bias input, also order 14852A.
12 System upgrades Upgrades available for existing Agilent 8510 systems to 8510XF single-sweep systems Upgrades for 85107B and 85109C Upg rade consists of tw o test heads, a millimeter test set controller , an 83621B for LO source, and rack. It does not include calibration kits or test port cables.
13 Upgrades for 85106C-001 and 85106C-002 (added 8517B, replaced 83621A/B with 83651A/B, and replaced 8350B/83540A with 83621A/B) • 85106D-001 (added 8517B and replaced 83621B with 83651B) • 85109C-002 (replaced 8350B/83540A with 83621A/B U pgrade consists of two test heads and a millime- ter test set.
14 T est set upgrades F or any Agilent 8510 test set • 08511-60008 add IF switching (Option 001) for multiple test set operation Miscellaneous compatibility upgrades • 83601A f or 8510C with 83621/31A shipped prior to Januar y 1, 1991 Includes on-site inst allation b y Agilent Customer Engineer .
Related Agilent literature 5965-8837E 8510 System Solutions Brochur e 5091-8484E 8510 F amily Network Analyzer Data Sheet 5091-8969E 8510 P erformance Upgr ades to Meet Y our New Design and Test Chall.
Agilent T echnologies’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. W e strive to ensure that you get the test and measurement capabili- ties you paid for and obtain the support you need.
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies 8510C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies 8510C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies 8510C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies 8510C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies 8510C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies 8510C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies 8510C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies 8510C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.