This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Contents • • i Contents Ethernet/Cresnet Interface: CEN -CN 1 Description 1 Functional Description 1 Physical Description 2 .
.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 1 Ethernet/Cresnet Interface: CEN -CN Description Functional Description The CEN-CN i.
Ethernet/Cresnet Interface Crestron CEN -CN 2 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Physical Description The CEN-CN, shown below, is housed in a black enclosure with silk-screened labels on the front and rear panels.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 3 12VDC .5 A This DC power socket connector is used to supply power via an external power pack. Crestron recommends specific power packs for its devices.
Ethernet/Cresnet Interface Crestron CEN -CN 4 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 ETHERNET This 8-pin, 8-position RJ45 port connects the CEN-CN to a 10BaseT Ethernet/LAN or WAN via a hub. Refer to the table below for the pinouts.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 5 Leading Specifications of the CEN-CN SPECIFICATION DETAILS Power Requirements 12VDC, external power pack or 24VDC, .
Ethernet/Cresnet Interface Crestron CEN -CN 6 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 network port, the load factor of that unit is the load factor of the entire run.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 7 Before installing any development tools, confirm that all other applications such as Microsoft ® Office, etc. are closed. The website and CD provide instructions for installing the various tools.
Ethernet/Cresnet Interface Crestron CEN -CN 8 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Typical Connections When Configuring the CEN-CN CRESTRON ELECTRONICS INC. ROCKLEIGH, N.J. 07647 USA CRESTRON ELECTRONICS INC. ROCKLEIGH, N.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 9 5. Refer to figure below. From the Setup menu, verify that Auto Baud Search is checked. Verifying Auto Baud Search 6. Refer to figure below.
Ethernet/Cresnet Interface Crestron CEN -CN 10 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Port Settings Dialog Box 8. Select Diagnostics | Check Operating System Version (alternatively, depress F5 ) from the Viewport. The Viewport may display a window as it scans various baud rates.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 11 Updating the CEN-CN The CEN-CN contains an Operating System, a Monitor ROM, and TCP/IP Stack. All three are separate components but packaged together in a Control System Update File.
Ethernet/Cresnet Interface Crestron CEN -CN 12 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Update Control System Dialog Box NOTE: After a file is selected, the “Update Co.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 13 5. As a result of the update, a dialog box (similar to as shown below) may open and the SIMPL program (and possibly SIMPL+ modules) must be cleared.
Ethernet/Cresnet Interface Crestron CEN -CN 14 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Set IP Information via Viewport 2. Observe a dialog box similar to as shown below. As shown, the CEN -CN does not have an IP address assigned to it.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 15 3. Refer to the two tables below and enter the network IP values. NOTE: If an invalid IP address is entered, the subnet mask may be CHANGED AUTOMATICALLY BY THE EQUIPMENT to an appropriate subnet mask.
Ethernet/Cresnet Interface Crestron CEN -CN 16 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Reboot Dialog Box 6. Observe a confirmation message that the IP information has been setup. After the system reboots, select Function | Cold Boot , to view the IP Information.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 17 and list it in the dialog box. Modify or delete existing entries or add new ones. When all the necessary changes have been made, save the new table to disk and/or load it back into the unit.
Ethernet/Cresnet Interface Crestron CEN -CN 18 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Typical Connections for Normal Operation CRESTRON ELECTRONICS INC. ROCKLEIGH, N.J. 07647 USA CRESTRON ELECTRONICS INC. ROCKLEIGH, N.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 19 2. Enter the IP address of the configured CEN-CN and click the Connect button. (Within the address, X and Y may range from 0 to 255. In the example shown below, X is 1 and Y is 2.
Ethernet/Cresnet Interface Crestron CEN -CN 20 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 SIMPL™ Windows ® Example Program SIMPL (Symbol Intensive Master Programming Language) is an easy-to-use programming language that is completely integrated and compatible with all Crestron system hardware.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Ethernet/Cresnet Interface: CEN-CN • • 21 CEN-CN Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Improper Ethernet cable connections. Verify cable connections with LAN: proper connection is used, cable intact, and connections are secure.
Ethernet/Cresnet Interface Crestron CEN -CN 22 • • Ethernet/Cresnet Interface: CEN-CN Operations Guide - DOC. 5721 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Glossary of Terms • • 23 Glossary of Terms CIP Cresnet (over) Internet Protocol is a combination of Cresnet and Internet protocols.
Ethernet/Cresnet Interface Crestron CEN -CN 24 • • Glossary of Terms Operations Guide - DOC. 5721 IP ID The IP ID is a two-digit hexadecimal number that is used to differentiate a given device from a group of Ethernet devices in a control system with the same IP address.
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Glossary of Terms • • 25 TCP/IP TCP/IP stands for Transmission Control Protocol/Internet Protocol. It is quite simply a standard set of protocols that govern the basic workings of the Internet that was implemented in 1982.
Ethernet/Cresnet Interface Crestron CEN -CN 26 • • Glossary of Terms Operations Guide - DOC. 5721 This page intentionally left blank..
Crestron CEN-CN Ethernet/Cresnet Interface Operations Guide - DOC. 5721 Glossary of Terms • • 27 This page intentionally left blank..
Crestron Electronics, Inc. Operations Gui de – DOC. 5721 15 Volvo Drive Rockleigh, NJ 07647 11.00 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.
Een belangrijk punt na aankoop van elk apparaat Crestron CEN-CN (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crestron CEN-CN heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crestron CEN-CN vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crestron CEN-CN leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crestron CEN-CN krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crestron CEN-CN bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crestron CEN-CN kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crestron CEN-CN . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.