Crestron CSP-LSP Cresnet ® Lightning Strike Protector Operations & Installation Guide.
This document was prepared and written by th e Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand nam es, product names and trade marks are the property of t heir respective ow ners.
Crestron CSP-LSP Lightning Strike Protector Contents Cresnet ® Lighting Strike Protector: Crestron CSP-LSP 1 Introduc tion ................................................................................................................... ...........
.
Crestron CSP-LSP Lightning Strike Protector Cresnet ® Lighting Strike Protector: Crestron CSP-LSP Introduction The CSP-LSP is an accessory de signed to protect a Crestron ® control system from lightning surges and other electrical disturbances brought through the Cresnet control line.
Lightning Strike Protector Crestron CSP-LSP that span multiple buildings, a separa te CSP-LSP can be installed in each building to protect all of the lo cal devices within each building. The CSP-LSP is designed for mounting to a wall or similar flat surface.
Crestron CSP-LSP Lightning Strike Protector Applications The following diagrams show the CSP-LSP in a series of different applications. CSP-LSP Application for Local Systems Operations & Installation Guide – DOC.
Lightning Strike Protector Crestron CSP-LSP CSP-LSP Application for Long Runs 4 • Lightning Strike Protector: CSP-LSP Operations & Installation Guide – DOC.
Crestron CSP-LSP Lightning Strike Protector CSP-LSP Application for Mu ltiple Building Systems Operations & Installation Guide – DOC. 6643A Lightning Strike Protector: CSP-LSP • 5.
Lightning Strike Protector Crestron CSP-LSP Specifications Specifications for the CSP-LSP are listed in the following table. CSP-LSP Specifications SPECIFICATION DETAILS Protection 4-stage protection .
Crestron CSP-LSP Lightning Strike Protector Physical Description This section provides information on the connections available on your CSP-LSP. CSP-LSP Physical View Operations & Installation Guide – DOC.
Lightning Strike Protector Crestron CSP-LSP CSP-LSP Overall Dimensions 1.75 i n (4.45 c m ) 5.23 in (13.29 cm ) 3.40 in (8.64 c m ) 1.83 in (4.65 cm ) 1 3 2 2 5.64 i n (14. 32 cm) Connectors, Controls & Indicators # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 1 DEVICE (4) 4-pin 3.
Crestron CSP-LSP Lightning Strike Protector Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 2 GROUND (2) 10-32 studs, chassis ground lugs 2 ; 3 ft flat braided grounding strap included; Ground bus bar included for daisy chaining to a second CSP-LSP unit.
Lightning Strike Protector Crestron CSP-LSP Industry Compliance As of the date of manufacture, the CSP-LSP has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron CSP-LSP Lightning Strike Protector Setup Network Wiring When wiring the network use Crestron Certified Wire. For more details, refer to “Che ck Network Wiring” on page 17. Supplied Hardware The hardware supplied with the CSP-LSP is listed in the following table.
Lightning Strike Protector Crestron CSP-LSP Ground Clamp Necessary grounding hardwa re is provi ded with your CSP-LSP. Refer to the image below when installing th e braided ground strap (4505505) and ground clamp (2019803) to a grounded cold water pipe.
Crestron CSP-LSP Lightning Strike Protector Hardware Hookup The CSP-LSP can be connected loca lly to protect a nearby control system and Cresnet devices. The C SP-LSP can also be connected to remote Cresnet devices or anothe r CSP-LSP to provide protection to Cresnet devices that are connected w ith substantially longer wire runs.
Lightning Strike Protector Crestron CSP-LSP Remote Connectio ns Remote connections refer to connecti ons made from the locally connected CSP-LSP to Cresnet devices connected by wire runs exceeding 500 feet or wire runs situated outdoors, includi ng wire runs underground.
Crestron CSP-LSP Lightning Strike Protector Operation The CSP-LSP can be connected either locally or remotely, while up to two CSP-LSP devices may be daisy chained together in either connection configuration. Local CSP-LSP Operation Locally, one of the CONTROL SYSTEM ports must be connected to the control system.
Lightning Strike Protector Crestron CSP-LSP Daisy Chaining Up to two CSP-LSP units can be dais y chained when a C2N-HBLOCK is not a practical option. Daisy chai ning two CSP-LSP units provide up to four protected CONTROL SYSTEM ports.
Crestron CSP-LSP Lightning Strike Protector Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations.
Lightning Strike Protector Crestron CSP-LSP Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take a dvantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-27 3-7876].
Crestron CSP-LSP Lightning Strike Protector Return and Warranty Policies Merchandise Returns / Repair Service 1. No m erchandise m ay be returned for cre dit, exchan ge or service with out prior au thorization from CR ESTRON. To obt ain warranty serv ice for CREST RON products, contact an authorized CRESTRON deal er.
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6643A 15 Volvo Drive Rockleigh, NJ 07647 (2019895) Tel: 888.CRESTRON 02.08 Fax: 201.
Een belangrijk punt na aankoop van elk apparaat Crestron electronic CSP-LSP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crestron electronic CSP-LSP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crestron electronic CSP-LSP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crestron electronic CSP-LSP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crestron electronic CSP-LSP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crestron electronic CSP-LSP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crestron electronic CSP-LSP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crestron electronic CSP-LSP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.