Power Base-1 & 460CSL Amplifier Service Manual 1 POWER BASE-1 ® & 460CSL ™ PO WER AMPLIFIER SER VICE MANU AL K-SVCPB1 1-95 CSL ™ is a trademark and Power Base-1, ® ODEP ® and Crown ® are registered trademarks of Crown International, Inc.
Power Base-1 & 460CSL Amplifier Service Manual 2 À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES À L’INTÉRIEUR. DÉBRANCHER LA BORNE AVANT D’OUVRIR LA MODULE EN ARRIÈRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS.
Power Base-1 & 460CSL Amplifier Service Manual 3 Introduction ............................................................. 4 Scope ...................................................................... 4 Warranty .................................
Power Base-1 & 460CSL Amplifier Service Manual 4 Crown Technical Support Group Factory Service Parts Department Mailing Address: PO Box 1000 Elkhart, IN USA 46515-1000 Shipping Address: 57620 C.
Power Base-1 & 460CSL Amplifier Service Manual 5 Parts shipment on a C.O.D. or pre-payment (check or credit card) basis. TERMS Normal terms are pre-paid.
Power Base-1 & 460CSL Amplifier Service Manual 6 Specifications Unless noted otherwise, all specifications are based on driving an 8 ohm load per channel, both channels driven, the sensitivity switch in the 26dB position, the AC supply is 120V AC at 60Hz.
Power Base-1 & 460CSL Amplifier Service Manual 7 V oltage Conversion Note: The only versions of this product pr oduced at the Crown Factory with inter national volt- age capabilities built in ar e CSL versions built specifically for sale outside the United States.
Power Base-1 & 460CSL Amplifier Service Manual 8 Theor y OVERVIEW It should be noted from the outset that the PB-1 and 460CSL amplifiers are electrically and mechanically identical products. The only differences, from a ser- vice perspective, are cosmetic.
Power Base-1 & 460CSL Amplifier Service Manual 9 Theor y tivity is achieved by controlling the ratio of feedback to input resistance. The Sensitivity Switch sets the input impedance to this stage and varies the gain such that the overall amplifier gain is 26 dB, or is adjusted appropriately for 0.
Power Base-1 & 460CSL Amplifier Service Manual 10 allows the NFb loop to control Error Amp gain by feeding back to its non-inverting input (with its polarity opposite to the output of the VGS). With the added voltage swing provided by the LVAs, the signal then gains current amplification through the Darlington emitter-follower output stage.
Power Base-1 & 460CSL Amplifier Service Manual 11 the positive half, and about .5V across the bias resistor in the negative half. Q18 conduction (and thus bias) is adjustable. A diode string prevents excessive charge build up within the high conduction output devices when off.
Power Base-1 & 460CSL Amplifier Service Manual 12 Theor y ±ODEP circuitry is used to simulate the thermal barri- ers between the interior of the output device die (immeasurable by normal means) and the time delay from heat generation at the die until heat dissipates to the thermal sensor.
Power Base-1 & 460CSL Amplifier Service Manual 13 Checkout Procedures GENERAL INFORMATION The following test procedures are to be used to verify operation of this amplifier. DO NOT connect a load or inject a signal unless directed to do so by the proce- dure.
Power Base-1 & 460CSL Amplifier Service Manual 14 TEST 4: AC POWER DRAW Spec: 90 Watts maximum quiescent. Initial Conditions: Controls per standard. Procedure: With no input signal and no load, measure AC line wattage draw. If current draw is excessive, check for high AC line voltage or high bias voltage.
Power Base-1 & 460CSL Amplifier Service Manual 15 Checkout Procedures Procedure Capacitive: Load each channel to 8 ohms in parallel with 2 µF. Inject a 20 kHz sine wave with 30 VAC output for 10 seconds. Procedure Inductive: Load each channel to 8 ohms in parallel with 159 µHenries.
Power Base-1 & 460CSL Amplifier Service Manual 16 Checkout Procedures.
Power Base-1 & 460CSL Amplifier Service Manual 17 Mechanical (Non-Module) Parts SUPPLIMENTAL ITEMS CP N ITEM QTY D 4137-2 Nylon Thumbscrew W asher 4 C 3342-0 Feet, Black Self-Stick 4 A10087-71012 10-32 .75 Machine (Rack Screw) 4 120VAC/60HZ NORTH AMERICA PRODUCT ONLY CP N ITEM QTY A10285-26 Fuse, 10A 3AB (120V Units) 1 A10285-7 Fuse, .
Power Base-1 & 460CSL Amplifier Service Manual 18 Mechanical (Non-Module) Parts OUTPUT ASSEMBLY (ONE PER CHANNEL) CP N ITEM QTY A10100-4 W asher , #6 Flat Zinc 2 A10315-1 Screw , 6-32-.
Power Base-1 & 460CSL Amplifier Service Manual 19 Mechanical (Non-Module) Parts MAIN CHASSIS ASSEMBLY CP N ITEM QTY A10086-11008 Screw , 10-32-.5 Mach Rd Ph 4 A10086-70806 Screw , 8-32-.
Power Base-1 & 460CSL Amplifier Service Manual 20 Module Information MODULE HISTORY Since its introduction in 1986, the PB-1 has gone through a number of updates and revisions. Over the course of its history some of these changes have resulted in upgrading to newer modules.
Power Base-1 & 460CSL Amplifier Service Manual 21 Q42576-1 Output Module Parts List (P10137-1 Board) Q42576-1 Output Module (4 Resistor Original) for PB-1: CAPACITORS C01 C 3978-1 .047µF C02 C 6804-6 .1µF C03 C 6804-6 .1µF C04 C 3996-3 .0047µF C05 C 6807-9 .
Power Base-1 & 460CSL Amplifier Service Manual 22 Q42661-1 Output Module Parts List (P10137-1 Board) Q42661-1 Output Module (4 Resistor #2) for PB-1: CAPACITORS C01 C 3978-1 .047µF C02 C 6804-6 .1µF C03 C 6804-6 .1µF C04 C 3996-3 .0047µF C05 C 6807-9 .
Power Base-1 & 460CSL Amplifier Service Manual 23 Q42718-9 Output Module (4 Resistor #3) for PB-1: CAPACITORS C01 C 3978-1 .047µF C02 C 3218-2 .22µF C03 C 3218-2 .22µF C04 C 8534-7 .0047µF C05 C 6807-9 .001µF C06 C 6806-1 .01µF C07 C 6807-9 .
Power Base-1 & 460CSL Amplifier Service Manual 24 Q42885-6 Output Module Parts List (P10305-4 Board) Q42885-6 Output Module (4 Resistor TO-3P Drivers) for PB-1/460CSL: CAPACITORS C01 C 8511-5 .047µF C02 C 7964-7 .22µF C03 C 7964-7 .22µF C04 C 8534-7 .
Power Base-1 & 460CSL Amplifier Service Manual 25 Q42967-2 Output Module for Through Hole Chassis (THC) PB-1/460CSL units: CAPACITORS C01 C 8511-5 .047µF C02 C 7964-7 .22µF C03 C 7964-7 .22µF C04 C 8534-7 .0047µF C05 C 8534-7 .0047µF C06 C 6806-1 .
Power Base-1 & 460CSL Amplifier Service Manual 26 Q43200-7 Output Module (THC #2) for PB-1/460CSL Units: CAPACITORS C01 C 8511-5 .047µF C02 C 7964-7 .22µF C03 C 7964-7 .22µF C04 C 8534-7 .0047µF C05 C 8534-7 .0047µF C06 C 6806-1 .01µF C07 C 6807-9 .
Power Base-1 & 460CSL Amplifier Service Manual 27 Q42552A0 Main Module Parts List (D 6304B2 Board) Q42552A0 Main Module (Original) for PB-1: CAPACITORS C1 C 4303-1 1000uF C2 C 3913-8 470uF C3 C 4303-1 1000uF C4 C 6802-0 .47uF C100 C200 C 5053-1 18uF C101 C201 C 2821-4 10pF C103 C203 C 6805-3 .
Power Base-1 & 460CSL Amplifier Service Manual 28 R114 R214 A10266-4721 4.7K R115 R215 A10266-5141 510K R116 R216 A10266-3351 3.3M R118 R218 A10266-2711 270 OHM R119 R219 A10266-3011 300 OHM R120 R220 A10266-2711 270 OHM R121 R221 C 5062-2 100K TRIMMER R122 R222 A10266-2741 270K R123 R223 A10266-1831 18K R124 R224 A10266-6821 6.
Power Base-1 & 460CSL Amplifier Service Manual 29 Q42664-5 Main Module Parts List (D 6910-0 Board) Q42664-5 Main Module (Service Replacement For Origi- nal) for PB-1: CAPACITORS C1 C 4303-1 1000uF C2 C 3913-8 470uF C3 C 4303-1 1000uF C4 C 6802-0 .
Power Base-1 & 460CSL Amplifier Service Manual 30 R110 R210 A10266-4731 47K R111 R211 A10266-1231 12K R112 R212 A10266-5131 51K R113 R213 A10266-4721 4.
Power Base-1 & 460CSL Amplifier Service Manual 31 Q42682-7 Main Module Parts List (D 6910-0 Board) Q42682-7 Main Module (#2) for PB-1: CAPACITORS C1 C 4303-1 1000uF C2 C 3913-8 470uF C3 C 4303-1 1000uF C4 C 6802-0 .47uF C5 OPEN C6 OPEN C100 C200 C 5311-3 22uF C101 C201 C 2820-6 5pF C103 C203 C 6805-3 .
Power Base-1 & 460CSL Amplifier Service Manual 32 RESISTORS R1 A10265-53621 53.6K 1% R2 OPEN R3 OPEN R4 A10265-46421 46.4K 1% R5 A10266-3323 3.3K 1W R1 0 OPEN R100 R200 C 7409-3 5K POT R101 R201 A10265-49911 4.99K R102 R202 A10266-1021 1K R103 R203 A10265-10031 100K 1% R104 R204 A10266-2721 2.
Power Base-1 & 460CSL Amplifier Service Manual 33 MISC. BOARD D 6910-0 MOUNTS U1, U2: (2) C 1889-2 6-32 NUT (2) C 2176-3 6-32 X .5 SCREW (2) C 5341-0 HEA TSINK (2) C 5594-4 ST AR W ASHER MOUNTS U1.
Power Base-1 & 460CSL Amplifier Service Manual 34 Q42776-7 Main Module Parts List (D 7251-8 Board) Q42776-7 Main Module (3rd Gain) for PB-1: CAPACITORS C1 C 3913-8 470uF C2 C 3913-8 470uF C4 C 6802-0 .47uF C5 C 6806-1 .01uF C6 C 6806-1 .01uF C7 C 6094-9 33uF C8 C 6806-1 .
Power Base-1 & 460CSL Amplifier Service Manual 35 Q116 Q216 C 3786-8 PN4250A Q117 Q217 D 2961-7 SEL 2N3859A Q118 Q218 D 2961-7 SEL 2N3859A Q119 Q219 C 3625-8 2N4125 Q120 Q220 C 3625-8 2N4125 Q121 Q221 C 7458-0 2N4123 Q122 Q222 C 7458-0 2N4123 RESISTORS R1 A10265-53621 53.
Power Base-1 & 460CSL Amplifier Service Manual 36 INTERCONNECTS J1 C 7593-4 HEADER 5 PIN J2 C 4508-5 16 PIN SOCKET J9 C 7527-2 HEADER 6 PIN J10 C 7592-6 HEADER 4 PIN J11 C 7526-4 HEADER 3 PIN J100 J200 C 6777-4 PHONE JACK J500 J800 D 6619-7 10" RIBBON ASSY J600 J700 D 6620-5 6" RIBBON ASSY MISC.
Power Base-1 & 460CSL Amplifier Service Manual 37 Q42953-2 PB-1 Main Module 3rd Gain Stage and Improved offset (Original 460CSL Main Module.): CAPACITORS C1 C 3913-8 470µF C2 C 3913-8 470µF C4 C 6802-0 .47µF C5 C 6806-1 .01µF C6 C 6806-1 .01µF C7 C 6094-4 33µF 16V C8 C 6806-1 .
Power Base-1 & 460CSL Amplifier Service Manual 38 RESISTORS N100 N200 D 4669-4 CMR Trim Network N101 N201 D 6081-0 Resistor Network N102 N202 D 6082-8 Resistor Network R1 A10265-53621 53.6K 1% R2 C 7340-0 24 5W R3 C 7340-0 24 5W R4 A10265-46421 46.
Power Base-1 & 460CSL Amplifier Service Manual 39 MISC. Board D 7251-8 Blank PC Board Socket C 3450-1 14 Pin U104/204 Nut A10102-5 Hex 6-32 Heatsink C 5341-0 TO-220 Torq Sprdr C 6541-4 Washer C 89.
Power Base-1 & 460CSL Amplifier Service Manual 40 Q43060-5 Applicability: Main Module for Through Hole Chassis (THC) PB-1/460CSL units. CAPACITORS C1 C 4303-1 1000µF C2 C 3913-8 470µF C4 C 6802-0 .47µF C5 C 6806-1 .01µF C6 C 6806-1 .01µF C7 C 8897-8 .
Power Base-1 & 460CSL Amplifier Service Manual 41 Q43060-5 Main Module Parts List (D 7993-5 Board) Q119 Q219 C 3625-8 NPN 2N4125 Q120 Q220 C 3625-8 NPN 2N4125 Q121 Q221 C 7458-0 NPN 2N4123 Q122 Q2.
Power Base-1 & 460CSL Amplifier Service Manual 42 Q43060-5 Main Module Parts List (D 7993-5 Board) R191 R291 A10266-3331 33K R192 R292 A10266-1031 10K R193 R293 A10266-1031 10K R194 R294 A10266-1041 100K R195 R295 A10266-3021 3K R196 R296 A10266-4721 4.
Een belangrijk punt na aankoop van elk apparaat Crown 460CSL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crown 460CSL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crown 460CSL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crown 460CSL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crown 460CSL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crown 460CSL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crown 460CSL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crown 460CSL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.