D e s i g n e D t o L e a D T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
.
I Pr oduct Description This supplement covers information not included in the standard Series 32 installation manual that is unique to the following models: 32-380WNLECS, 32-475WNLECS 32-380WNTECS, 32-475WNTECS 32-380SNLECS, 32-475SNLECS Follow the Series 32 installation instructions except where noted in this supplement.
VII V enting Refer to installation manual. V ent sizing for the 32-380ECS should always be done in accordance with the National Fuel Gas Code. A vent damper can be installed on any 32-380ECS or 32-475ECS equipped with a 24 volt control system except for those with tankless heaters.
W ARNING All wiring and grounding must be done in accordance with the authority having jurisdiction or , in the absence of such CAUTION Make sure that damper and BVS harnesses are secured so that they do not come in contact with draft hood or steam piping.
“BURNER” “BURNER” TH TR + ROBERTSHAW 7000DERHC GAS V AL VE VENT DAMPE R (NOTE 2) NOTE 2 LESS VENT DAMPER 2. ON BOILERS LESS VENT DAMPER, DAMPER HARNESS NOT USED. RED AND BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE. RD RD RD ALARM ALARM 2 (NOTE 2) 2.
Sequence of Operation - Steam Boiler 1) When the boiler is ener gized, 24 volts is immediately applied to terminals “1” (blue) and “4” (yellow) on the vent damp - er . Assuming that there is no call for heat, and that the damper switch is in the “automatic” position, the damper will close.
2 HIGH LIMIT LOW LIMIT HONEYWELL L8124E TH TR + ROBERTSHAW 7000DERHC GAS VAL VE PILOT VAL VE MAIN VAL VE RD RD RD/YE RD RD/YE ALARM ALARM Figure C: W ater Boiler Wiring (W ith T ankless Heater) Figure.
equipped with a reset button which must be pressed to restore normal burner operation. An open blocked vent switch is indicative of a problem with the vent system. If the blocked vent switch opens, the cause of the venting problem must be found and corrected by a qualied gas service technician before the blocked vent switch is reset.
Figure F: W ater Boiler Contr ol Installation (Less T ankless Heater V ersion Shown) Figure E: Blocked V ent Switch Installation 8.
6) Once the ignition module detects the presence of a pilot ame, voltage is applied across the main valve (terminals “MV” and “MV/PV”), opening the valve and establishing main ame.
380 475 380 475 I A PART # (STANDARD) 310000 310001 310002 3110053 3110063 310405 310406 311026 311020 311010 310400 311027 311028 311031 1 EA. 1 EA. BOILER MODEL 32-380ECS 1 1 3 1 1 1 1 1 1 1 1 31103.
BASE SIDE CAR TON - See Installation Manual JACKET SIDE P ANEL CAR TON- See Installation Manual W A TER AND STEAM BOILER CAR TONS - As shown in Installation Manual except that Rating Plate is factory applied to RH Side Jacket Panel.
12 STEAM PROBE CONTROL SUB ASSY 3513210 1 LWCO, CG400 WITH "P" PROBE 400824 1 BLOCKED VENT SWITCH ASSY 960128 1 GLASS SET (20-104-10, 8" CTR TO CTR) 950080 1 L404F PRESSURE LIMIT 350380.
.
PN 980895 05/10 T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
Een belangrijk punt na aankoop van elk apparaat Crown Boiler 32-475ECS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crown Boiler 32-475ECS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crown Boiler 32-475ECS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crown Boiler 32-475ECS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crown Boiler 32-475ECS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crown Boiler 32-475ECS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crown Boiler 32-475ECS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crown Boiler 32-475ECS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.