Gebruiksaanwijzing /service van het product New 160 Series 160 Series van de fabrikant Aico
Ga naar pagina of 15
(68.52) X New 160 Series now New 160 Series now with REMOTE CONTROL with REMOTE CONTROL functionality functionality New 160 Series now with REMOTE CONTROL functionality Pr oduct Guide f or Smoke &.
The Solution Pr o vider f or Smok e & Heat Alar m Installation Standards The Ei Range of Smoke Alarms from Aico of fers the complete solution to meeting the new requirements of BS 5839: Pt.
Residential Fire Detection & Regulations ... ho w do the y af f ect me? What do Building Regulations Demand in Ne w Build and Mater ially Altered Dw ellings? Architects, builders and installer s must comply with Building Regulations and install mains po wered smok e alarms in new and materially altered dwellings.
Ionisation Alar ms where should they be used? Ionisation type sensors are par ticularly sensitive to the almost invisible smoke pr oduced by f ast flaming f ires . This makes them more liable to f alse alarm due to cooking fumes if sited in a hallway close to a kitchen.
Selection, P ositioning, W ir ing Smok e & Heat Alar ms 5 SITING DIA GRAMS Simple Inter connect Wir ing f or all Mains P o w ered Smoke and Heat Alar ms 140/160RC Series 140/160RC Series T o mains pow er supply - e.
Inno v ativ e Design & Quality F eatures Ei's unique large v olume optical smoke chamber & sophisticated electronics have a pr o ven tr ack record of reliability and high ef f iciency detection.
7 Pr oduct Specif ications Remote Control System Option ✔✔ Ionisation Sensor ✔✔✔ Optical Sensor ✔✔✔ Heat Sensor ✔✔✔ Mains Supply ✔✔ ✔✔ Lithium Rechargeable Cell Back-up .
8 The 160RC Series , Easi-fit m ains pow ered smoke and heat alar ms are our highest specif ication range, especially so w hen coupled to the RadioLINK system.
COLOUR CODED P A CKA GING FOR EASY RECOGNITION COLOUR CODED P A CKA GING FOR EASY RECOGNITION BS 5446: Pt.1: 2000 Ei161RC Ionisation BS 5446: Pt.1: 2000 Ei166RC Optical 9 TEST T est all alar ms from one conv enient switch HUSH Any nuisance alarm can be quickly and easily silenced LOC ATE Allo ws the source of the alar m to be identif ied.
10 RadioLINK Wireless F or use with 160RC Ser THE COMPLETE SOLUTION T O THE NEW BS 5839: Pt.6: 2004 REQUIREMENTS Interconnecting m ains pow ered smoke alar ms is essential to pro vide the ear liest possible warning of a fire. Fire statistics show that the quicker occupants are alerted to a f ire, the less r isk of death or injur y there is.
Inter connection ies Smoke & Heat Alarms RadioLINK SYSTEM CONTROL DEVICES Slide a 160RC Series alarm on to the Ei168RC base which will automatically activate the rechargeable back-up cells, and then repeat this procedure f or all the alarms in the system.
MAINS PO WERED ALARMS WITH ALKALINE BA TTERY BA CK-UP Designed f or applications where the budget is a ke y consideration and where maintenance is in the hands of the owner occupier or there is no requirement f or lithium pow er cell back-up. The 140 Series provides an alkaline battery back-up instead of rechargeable cells.
Alar m Systems f or the Deaf & Hear ing Impaired People with hearing dif ficulties require a dif ferent approach to f ire protection, as a conventional alarm sounder will not be suf ficient f or their needs.
Lo w V oltage Smok e & Heat Alar ms Other Smok e & Heat Alar ms and Contr ol In properties where there is a requirement to connect smoke and heat alarms to a low voltage security system, or W arden Call System, the Ei180 Series alar ms can pro vide the ideal solution.
De vices 15 NO ALARM - NO CHANCE! Carbon Monoxide or (CO), is a par ticular ly insidious gas. It is a killer . The naked e ye can't see it, it does not smell, it has no taste. The need f or a reliable mains pow ered alar m that will operate ev en in the ev ent of a mains f ailure is obvious.
Een belangrijk punt na aankoop van elk apparaat Aico New 160 Series 160 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aico New 160 Series 160 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aico New 160 Series 160 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aico New 160 Series 160 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aico New 160 Series 160 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aico New 160 Series 160 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aico New 160 Series 160 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aico New 160 Series 160 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.