Ins t all a tio n I nst r u c tio ns R ena issance ® Ele ct ric Range Part No. 105910 Rev . C Models: RR30NS[-C], RR30NFS[-C], RR30NIS[-C] and RR30NIFS[-C] wi th i nduction cooktop.
T able of Contents IMPORT ANT : • Installer : In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer .
1 Impor tant Information About Safety Instructions The Important Safety Instructions and warnings in this manual are not meant to cover all possible problems and conditions that can occur . Use common sense and caution when installing, maintaining or operating this or any other appliance.
2 Impor tant Safety Instructions General Safety Precautions T o reduce the risk of fire, explosion, electric shock, serious injury or death when installing or using this appliance, follow basic safety precautions, including the following: • Read all instructions before using the appliance.
3 Product Specifications W ARNING IMPORT ANT : Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
4 Product Specifications 1” (2.5 cm) Front of open door Front of handle Front panel Rear of front panel Backguard thickness 3” (7.6 cm) backguard* External handle shown, some models have integral handle (see inside cover) 6” (15.2 cm) backguard* * See table for compatibility Product width: 29 15/16” (76.
5 Installation Specifications Cabinet Layout W ARNING • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • All minimum cabinet/countertop clearances shown on the following pages must be met or exceeded.
6 Installation Specifications Rear wall or countertop edge countertop opening 29 1/4” (74.3 cm) 30 1/16” (76.2 cm) cabinet opening below countertop below countertop Cabinet face Notch countertop to width of cabinets 3/8” min. (9.5 mm) countertop overhang 1” min.
7 Installation Specifications T op View - Downdraft ER V30[15] with Slide-In, Self-Rimming Installation, 3” Side Panels Installed T op View - Downdraft ER V30[15] with Slide-In, Self-Rimming Installation, 3” Side Panels Removed Rear wall or countertop edge countertop opening 29 1/4” (74.
8 Installation Instructions V erify the Package Contents V erify that all the components below have been provided. If any item is missing or damaged, please contact your dealer immediately . Do not install a damaged or incomplete appliance. Make sure that you have everything necessary to ensure proper installation before proceeding.
9 T o determine if the base plate is high enough: a. Determine the location of the range center line and front panel when the range is in its final position based on the Product Dimensions on page 4 and the actual cabinet/cutout dimensions used for the installation.
10 Installation Instructions Backguard Installation If installing a backguard or changing the factory installed backguard, install it before moving the range into position. Do not install a backguard if installing a raised vent. Raised V ent Installation If installing a raised vent, install it before moving the range into position.
11 Connecting Conduit to the Range NOTE: See page 14 for instructions to connect an appliance cord to the range. 1. Remove the range electrical access cover from the back of the range. 2. If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link.
12 Installation Instructions Electrical Connection (cont.) Connecting the Conduit to the House Electrical Junction Box W ARNING • Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. • Do not ground the appliance to a gas supply pipe or hot water pipe.
13 Installation Instructions RED RED GREEN WHITE WHITE BLACK BLACK GREEN Fasten clamp tightly on pipe 3-Wire Conduit-Junction Box Connection with External Ground Separate No.
14 5. Slide the end of the appliance cord into the strain relief from the bottom of the box. See facing page. 6. Connect the white (neutral) wire to the neutral terminal in the box. 7. Connect the L1 wire to the L1 power supply terminal inside the box.
15 Installation Instructions L1 terminal L1 terminal L1 L1 L2 L2 Neutral Ground Neutral Neutral terminal Neutral terminal Jumper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire .
16 Installation Instructions Re-installing the Oven Door W ARNING T o avoid personal injury or damage to the door from it falling off its hinges: • Make sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door .
17 Installation Instructions V erifying Proper Operation 1. Remove any packaging from inside the oven. 2. Slide the oven racks onto the supports inside the oven chamber according to the use and care manual. 3. Prior to operating the range, please read the accompanying use and care manual carefully .
Dacor ● 14425 Clark Avenue, City of Industry , CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www .dacor .com.
Een belangrijk punt na aankoop van elk apparaat Dacor RR30NIFS[-C] (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dacor RR30NIFS[-C] heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dacor RR30NIFS[-C] vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dacor RR30NIFS[-C] leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dacor RR30NIFS[-C] krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dacor RR30NIFS[-C] bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dacor RR30NIFS[-C] kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dacor RR30NIFS[-C] . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.