QuickScan ® i QD2100 Barc ode Imager Pr oduc t Refer ence Guide.
Datalogic Scanning , Inc . 959 T erry Street Eugene , Oregon 97 402 T elephone: ( 541) 683-57 00 F a x: (541) 345-71 40 An Unpublished W ork - All ri ghts reser ved .
Product Reference Guide 1 T able of C on ten ts Chapter 1. Introduction . ............. .......... ............ .......... ............. ............. .......... ............ .......... ... .......... ............. .......... .......... ........... 1 About this Guide .
2 QuickScan ® QD2100 RS-232 Standard Factory Settings .......................... ......................... ........................ ................... .. ..................... ........................ ......................... ..... 41 Baud Rate ...
Product Referenc e Guide 3 Case Conversion ..................... ......................... ......................... ........................ ................ ..... ......................... ........................ ......................... .........
4 QuickScan ® QD2100 Code 39 .................... ........................ ......................... .................... ......................... ..... .................... ......................... ........................ ..................... ..
Product Referenc e Guide 5 Codabar Check C haracter Calculation ............................ ......................... ........................ .............. ........... ......................... .................... .... 214 Codabar Check C haracter Transmission .
6 QuickScan ® QD2100 Appendix B. Standard Defaults .................................................. ............................................ 271 Default Exceptions ........... ......................... ........................ .................
Product Reference Guide 1 Chapter 1 Introduc tion About this Guide This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications.
Introduction 2 QuickScan® QD2100 Chapter 11, Symbologies defines options for all symbologies and provides the program- ming barcodes necessary for configuring these features. Appendix A, Technical Specifications lists physical and performance characteristics, as well as environmental and regulatory specifications.
Technical Support Product Reference Guide 3 T echnical Suppor t Datalogic W ebsite Support The Datalogic website ( www.scanning.da talogic.com ) is the complete source for technical support and information for Datalogic products.
Introduction 4 QuickScan® QD2100 NO TES.
Product Reference Guide 5 Chapter 2 Getting Star ted About the Imager Advancements in the LED technology used in this imager significantly improve the illu- mination of the target field of view, resulting in higher scan efficiency.
Getting Started 6 QuickScan® QD2100 Setting Up the Imager Follow the steps provided in this section to connect and get your imager up and commu- nicating with its host: 1. Install the Interf ace Cable 2. Select the Interf ace T ype 3. Configure Interf ace Setting s (only if not using factory settings for that inter face) 4.
Setting Up the Imager Product Reference Guide 7 USB Connection — Connect the imager to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 2 . IBM Connection — Connect the imager to the IBM port on the terminal/PC using the correct IBM cable.
Getting Started 8 QuickScan® QD2100 U sing the Pr ogramming B arc odes This manual contains feature descriptions and barcodes which allow you to reconfigure your imager. Some programming barcode labels, like the Standard Product Default Set- tings on page 9 , require only the scan of that single label to enact the change.
Resetting the Standard Product Defaults Product Reference Guide 9 Resetting the Standard Pr oduc t Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Standard Prod uct Default Set- tings barcode below.
Getting Started 10 QuickScan® QD2100 NO TES.
Product Reference Guide 11 Chapter 3 Int er fac es Inter face Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models (5 v o lt supply) RS-232 RS-.
Interfaces 12 QuickScan® QD2100 Table 1. Available Interfaces RS-232 FEA TURES RS-232 standard interface Select RS232-STD Set RS-232 Interface F eatures star ting on page 41 Select RS232-WN RS-232 Wi.
Configuring the Interface Product Reference Guide 13 KEYBO ARD FEA TURES A T , PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard K ey Encoding Select KBD-A T Set KEYBOARD WEDGE Interfac.
Interfaces 14 QuickScan® QD2100 KEYBO ARD — cont. FEA TURES K eyboard W edge f or IBM T er minals 31xx, 32xx, 34xx, 37xx make only k eyboard Select KBD-IBM-M Set KEYBOARD WEDGE Interface Fe atures .
Global Interface Featur es Product Reference Guide 15 Global Inter face F eatures The following interface features are configurable by all interface types.
Interfaces 16 QuickScan® QD2100 USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode. ENTER/EXIT PROGRAMMING MODE USB Suspend Mode = Disable USB Suspend .
Product Reference Guide 17 Chapter 4 Ge ne r a l F e a tu r e s Double Read T imeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data.
General Features 18 QuickScan® QD2100 Double Read Timeout — continued ENTER/EXIT PROGRAMMING MODE Double Read Timeout = 0.5 Second Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second Double Read Timeout = 0.8 Second Double Read Timeout = 0.
Label Gone Timeout Product Reference Guide 19 Label Gone Timeout This feature sets the time after the last labe l segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 millisec- onds (2.
General Features 20 QuickScan® QD2100 Label Gone Timeout — cont. ENTER/EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
LED and Beeper Indicators Product Reference Guide 21 LED and Beeper Indicators Po we r O n A l e r t Disables or enables the indication (from the Beeper) that the reader is receiving power.
General Features 22 QuickScan® QD2100 Good Read: When to Indica te This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode.
LED and Beeper Indicators Product Reference Guide 23 Good Read Beep T ype Specifies whether the good read beep has a mono or bitonal beep sound. ENTER/EXIT PROGRAMMING MODE Good Read Beep T ype = Mono.
General Features 24 QuickScan® QD2100 Good Read Beep F requency Adjusts the good read beep to sound at a selectable low, medium or high frequency, se- lectable from the list below. (Controls the beeper’s pitch/tone.) Good Read Beep Length Specifies the duration of a good read beep.
LED and Beeper Indicators Product Reference Guide 25 Good Read Beep Length — continued ENTER/EXIT PROGRAMMING MODE Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Len.
General Features 26 QuickScan® QD2100 Good Read Beep V olume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
LED and Beeper Indicators Product Reference Guide 27 Good Read LED Dura tion This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.
General Features 28 QuickScan® QD2100 Good Read LED Duration — cont. ENTER/EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Scanning Features Product Reference Guide 29 Scanning F e atur es Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single — When the trigger is pulled, scanning is a.
General Features 30 QuickScan® QD2100 Scan Mode — continued ENTER/EXIT PROGRAMMING MODE Scan Mode = T rigger Single Scan Mode = T rigger Hold Multiple Scan Mode = T rigger Pulse Multiple Scan Mode .
Scanning Features Product Reference Guide 31 Stand Mode T riggered Timeout This feature specifies the time to remain in T rigger Single mode after the trigger is pulled while in Stand Mode . NO TE This timeout is only used when the Scan Mode is configured as Stand Mode .
General Features 32 QuickScan® QD2100 Stand Mode Triggered Timeout — continued ENTER/EXIT PROGRAMMING MODE Stand Mode T riggered Timeout = 6 Seconds Stand Mode T riggered Timeout = 8 Seconds Stand .
Scanning Features Product Reference Guide 33 Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre- ments.
General Features 34 QuickScan® QD2100 Scanning Active Time — cont. ENTER/EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Flash On Time Product Reference Guide 35 Fl a sh O n T i m e This feature specifies the ON time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature.
General Features 36 QuickScan® QD2100 Flash On Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Flash Off Time Product Reference Guide 37 Fl a sh O f f T im e This feature specifies the OFF time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature.
General Features 38 QuickScan® QD2100 Flash Off Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Stand Mode Sensitivity Product Reference Guide 39 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.
General Features 40 QuickScan® QD2100 Green Spot Dur ation Specifies the duration of the good read pointer beam after a good read. ENTER/EXIT PROGRAMMING MODE Green Spot Duration = Disable (Green Spo.
Product Reference Guide 41 Chapter 5 RS-232 ONL Y Int er fac e Introduction Use the programming barcodes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements.
RS-232 ONLY Interface 42 QuickScan® QD2100 Baud Rate — continued ENTER/EXIT PROGRAMMING MODE Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 DEF A UL T.
Data Bits Product Reference Guide 43 Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.
RS-232 ONLY Interface 44 QuickScan® QD2100 Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream.
Parity Product Reference Guide 45 Pa r i t y This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
RS-232 ONLY Interface 46 QuickScan® QD2100 Handshaking Con trol The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Hand- shaking Control includes the following options: • R TS — R TS is asserted during transmissions.
Product Reference Guide 47 Chapter 6 RS-232/USB-C om Int er faces Introduction The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces. Standard F ac tor y Set tings Reference Appendix B, Standard Defaults for a listing of standard factory settings.
RS-232/USB-Com Interfaces 48 QuickScan® QD2100 Intercharacter Dela y This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments.
Intercharacter Delay Product Reference Guide 49 Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Dela y = No Dela y Select Intercharacter Dela y Setting Make a mistak e? Scan the CANCEL barcode to abort and not sav e the entry string.
RS-232/USB-Com Interfaces 50 QuickScan® QD2100 Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a <BEL> character is de- tected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
ACK NAK Options Product Reference Guide 51 A C K NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK proto- col. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
RS-232/USB-Com Interfaces 52 QuickScan® QD2100 A CK Char ac ter This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desired character or value.
ACK NAK Options Product Reference Guide 53 ACK Character — cont. ENTER/EXIT PROGRAMMING MODE Select AC K Character Setting DEF A UL T 0x06 ‘ACK’ Character.
RS-232/USB-Com Interfaces 54 QuickScan® QD2100 NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desired character or value.
ACK NAK Options Product Reference Guide 55 NAK Character — cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting DEF A UL T 0x15 ‘NAK’ Character.
RS-232/USB-Com Interfaces 56 QuickScan® QD2100 AC K N A K T i m e o u t V a l u e This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments.
ACK NAK Options Product Reference Guide 57 ACK NAK Timeout Value — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout V alue Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
RS-232/USB-Com Interfaces 58 QuickScan® QD2100 A CK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
ACK NAK Options Product Reference Guide 59 ACK NAK Retry Count — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
RS-232/USB-Com Interfaces 60 QuickScan® QD2100 A CK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Indicate Transmission Failure Product Reference Guide 61 Indicate T ransmission F ailure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.
RS-232/USB-Com Interfaces 62 QuickScan® QD2100 Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set the value: 1. Determine the desired character or value.
Disable Character Product Reference Guide 63 Disable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Disable Character Setting DEF A UL T 0x44 = Disable Character is ‘D’.
RS-232/USB-Com Interfaces 64 QuickScan® QD2100 Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: Determine the desired character or value.
Enable Character Product Reference Guide 65 Enable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Enable Char acter Setting DEF A UL T 0x45 = Enable Character is ‘E’.
RS-232/USB-Com Interfaces 66 QuickScan® QD2100 NO TES.
Product Reference Guide 67 Chapter 7 K e yboard Inter fac e Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Standard F ac tor y Set tings Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Keyboard Interface 68 QuickScan® QD2100 Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes.
Country Mode Product Reference Guide 69 Country Mode — continued ENTER/EXIT PROGRAMMING MODE Countr y Mode = Denmark Suppor ts only the interf aces listed in theCountr y Mode f eature description. Country Mode = France Country Mode = Ger many Suppor ts only the interfaces listed in theCountry Mode feature description.
Keyboard Interface 70 QuickScan® QD2100 Country Mode — continued ENTER/EXIT PROGRAMMING MODE Country Mode = Poland Suppor ts only the interf aces listed in theCountr y Mode f eature description. Suppor ts only the interfaces listed in theCountry Mode feature description.
Caps Lock State Product Reference Guide 71 Cap s Lo c k St at e This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.
Keyboard Interface 72 QuickScan® QD2100 Send Control Char ac ters This feature Specifies how the reader transmits ASCII control characters to the host.
Wedge Quiet Interval Product Reference Guide 73 W edge Quiet Inter val This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.
Keyboard Interface 74 QuickScan® QD2100 Wedge Quiet Interval — cont. ENTER/EXIT PROGRAMMING MODE Select Wedge Quiet In ter val Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Intercharacter Delay Product Reference Guide 75 Intercharacter Dela y This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments.
Keyboard Interface 76 QuickScan® QD2100 Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Dela y = No Dela y Select Intercharacter Dela y Setting Make a mista ke? Scan the CANCEL barcode to abort and not sav e the entry string.
Intercode Delay Product Reference Guide 77 Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting.
Keyboard Interface 78 QuickScan® QD2100 Intercode Delay — cont. ENTER/EXIT PROGRAMMING MODE Set Intercode Delay Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
USB Keyboard Speed Product Reference Guide 79 USB K eyboard Speed This option specifies the USB poll rate for a USB keyboard. NO TE This feature applies ONL Y to the US B Keyboar d interface.
Keyboard Interface 80 QuickScan® QD2100 USB Keyboard Speed — continued ENTER/EXIT PROGRAMMING MODE USB K eyboard Speed = 6ms USB K eyboard Speed = 7ms USB K eyboard Speed = 8ms USB K eyboard Speed .
Product Reference Guide 81 Chapter 8 USB-OEM Inter face Introduction Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX Interface to specifically configure for the USB-OEM interface.
USB-OEM Interface 82 QuickScan® QD2100 USB-OEM Devic e Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have con- nected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
Product Reference Guide 83 Chapter 9 IBM 46XX Int er fac e Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. IBM Standard F ac tory S ettings Reference Appendix B, Standard Defaults for a listing of standard factory settings.
IBM 46XX Interface 84 QuickScan® QD2100 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The con- figurable range for this feature is 1 to 15 resets.
46xx Number of Host Resets Product Reference Guide 85 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 7 46xx Number of Host Resets = 8 46xx Number of Host.
IBM 46XX Interface 86 QuickScan® QD2100 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 13 46xx Number of Host Resets = 14 46xx Number of Host Resets = 1.
Transmit Labels in Code 39 Format Product Reference Guide 87 T ransmit Labels in C ode 39 F ormat This feature enable/disables translation to Code 39 before transmitting label data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the translation.
IBM 46XX Interface 88 QuickScan® QD2100 NO TES.
Product Reference Guide 89 Chapter 10 Data E diting Data Editing Ov erview When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user- defined data is called a “message string.
Data Editing 90 QuickScan® QD2100 Please K eep In Mind ... • M odifying a message string is n ot a mandatory requirement. Data editing is sophisti cated feature allowing highly customizable output for advanced users. F actor y default settings for data editing is typically set to NONE.
Global Prefix/Suffix Product Reference Guide 91 6. Scan the ENTER/EXIT barcode once again to exit P rogramming M ode. 7. The resulting message string would appear as follo ws: Scanned barcode data:123.
Data Editing 92 QuickScan® QD2100 Global AIM ID AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), follo wed by .
Global AIM ID Product Reference Guide 93 Global AIM ID — continued ENTER/EXIT PROGRAMMING MODE Global AIM ID = Disable Global AIM ID = Enable DEF A UL T.
Data Editing 94 QuickScan® QD2100 GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde- pendently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well.
Label ID Product Reference Guide 95 Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a barcode (symbology) type. It can be appended previ- ous to or following the transmitted barcode data depending upon how this option is en- abled.
Data Editing 96 QuickScan® QD2100 Table 17. Label ID Pre-loaded Sets Symbology Default Label ID set Alternate Label ID set ASCII character Hexidecimal val u e ASCII character Hexidecimal val u e COD .
Label ID Product Reference Guide 97 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 UPCA P8 A 410000 Q 510000 UPCE E 450000 D 440000 UPCE P2 E 450000 H.
Data Editing 98 QuickScan® QD2100 Label ID: Set Individually P er Symbology To configure a Label ID individually for a single symbology: 1. Scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as P refix) or AFTER (Enable as suf- fix) by scanning the appropriate barcode in the section Label ID Control on page 100 .
Label ID Product Reference Guide 99 Label ID — continued Table 18. Label ID E xamples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2.
Data Editing 100 QuickScan® QD2100 Label ID — continued Label ID C ontrol This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type.
Label ID Product Reference Guide 101 Label ID — continued Label ID Symbology Selection This option selects the symbology for which a Label ID is to be configured.
Data Editing 102 QuickScan® QD2100 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured.
Label ID Product Reference Guide 103 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured.
Data Editing 104 QuickScan® QD2100 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured.
Label ID Product Reference Guide 105 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured.
Data Editing 106 QuickScan® QD2100 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured.
Case Conversion Product Reference Guide 107 Case C onv ersion This feature allows conversion of the case of all alphabetic characters to upper or lower case. NO TE Case con version affects ONL Y scanned barcode data, and does not affect Label ID , Prefix, Suffix, or other appended data.
Data Editing 108 QuickScan® QD2100 Character Con version Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the char- acter that will be converted.
Character Conversion Product Reference Guide 109 Character Conversion — continued ENTER/EXIT PROGRAMMING MODE Configure Character Con version DEF A UL T 0x FFFFFFFFFFF FFFFF (No character conversion.
Data Editing 110 QuickScan® QD2100 NO TES.
Product Reference Guide 111 Chapter 11 S ymbologies Introduction The reader supports the following symbologies (barcode types). Options for each sym- bology are included in this chapter. S ymbologies Standar d F ac tory S ettings for S ymbologies Default settings are indicated at each feature/option with a green arrow.
Symbologies 112 QuickScan® QD2100 UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. UPC-A Check Character T ransmission Enable this option to transmit the check character along with UPC-A barcode data.
UPC-A Product Reference Guide 113 UPC-A — cont. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. UPC-A Number Sy stem Char ac ter T ransmission This feature enables/disables transmission of the UPC-A number system character.
Symbologies 114 QuickScan® QD2100 UPC-A — cont. In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read.
UPC-E Product Reference Guide 115 UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. UPC-E Check Character T ransmission Enable this option to transmit the check character along with UPC-E barcode data.
Symbologies 116 QuickScan® QD2100 UPC-E — cont. Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
UPC-E Product Reference Guide 117 UPC-E — cont. UPC-E Number Sy stem Char acter T ransmission This feature enables/disables transmission of the UPC-E system number character.
Symbologies 118 QuickScan® QD2100 UPC-E — cont. UPC-E Minimum Reads This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read.
GTIN Formatting Product Reference Guide 119 GTIN F ormatting This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
Symbologies 120 QuickScan® QD2100 EAN 13 The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. EAN 13 Check Character T ransmission Enable this option to transmit the check character along with EAN 13 barcode data.
EAN 13 Product Reference Guide 121 EAN 13 — cont. EAN-13 Flag 1 Char ac ter Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label.
Symbologies 122 QuickScan® QD2100 EAN-13 ISBN C on version This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
EAN 13 Product Reference Guide 123 EAN 13 — cont. EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.
Symbologies 124 QuickScan® QD2100 EAN 8 The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. EAN 8 Check Character T ransmission Enable this option to transmit the check character along with EAN 8 barcode data.
EAN 8 Product Reference Guide 125 EAN 8 — cont. Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. ENTER/EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 = Disable .
Symbologies 126 QuickScan® QD2100 EAN 8 — cont. EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.
UPC/EAN Global Settings Product Reference Guide 127 UPC/EAN Global Settings This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description.
Symbologies 128 QuickScan® QD2100 UPC/EAN Global Settings — cont. UPC/EAN Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE UPC/EAN Decoding Lev el = 1 UPC/EAN Decoding Le vel = 2 UPC/EAN Decodi.
UPC/EAN Global Settings Product Reference Guide 129 UPC/EAN Global Settings — cont. UPC/EAN C orrelation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 130 QuickScan® QD2100 UPC/EAN Global Settings — cont. UPC/EAN Pric e W eight Check This feature enables/disables calculation and verification of price/weight check digits.
UPC/EAN Global Settings Product Reference Guide 131 UPC/EAN Global Settings — cont. UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read.
Symbologies 132 QuickScan® QD2100 A dd-Ons The following features apply to optional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): •P 2 •P 5 • GS1-128 NO TE Contact Customer Support for adv anced programming of optional and conditional add-ons.
Add-Ons Product Reference Guide 133 Add-Ons — cont. Optional Add-ons — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-Ons = Enable P5 Optional Add-Ons = Disable GS1-128 Optional Add-Ons = Enable G.
Symbologies 134 QuickScan® QD2100 Add-Ons — cont. Optional Add-On T imer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see Optional GS1-128 Add-On Timer on page 137 .
Add-Ons Product Reference Guide 135 Add-Ons — cont. Optional Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 60ms Optional Add-on Timer = 70ms Optional Add-on Timer = 100m.
Symbologies 136 QuickScan® QD2100 Add-Ons — cont. Optional Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220.
Add-Ons Product Reference Guide 137 Add-Ons — cont. Optional GS1-128 Add-On T imer This option sets the timer expiration value to read the additional part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of this type, see Option- al Add-On Timer on page 134 .
Symbologies 138 QuickScan® QD2100 Add-Ons — cont. Optional GS1-128 Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 60ms Optional GS1-128 Add-On Timer = 70ms Optio.
Add-Ons Product Reference Guide 139 Add-Ons — cont. Optional GS1-128 Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 180ms Optional GS1-128 Add-On Timer = 200ms Op.
Symbologies 140 QuickScan® QD2100 Add-Ons — cont. P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base labe l.
Add-Ons Product Reference Guide 141 Add-Ons — cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base labe l.
Symbologies 142 QuickScan® QD2100 Add-Ons — cont. GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base labe l.
GS1 DataBar Omnidirectional Product Reference Guide 143 GS1 DataBar Omnidirectional The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology. GS1 DataBar Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes.
Symbologies 144 QuickScan® QD2100 GS1 DataBar Omnidirectional — cont. GS1 DataBar Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omni- directional label must be decoded before it is accepted as good read .
GS1 DataBar Expanded Product Reference Guide 145 GS1 DataBar Expanded The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology. GS1 DataBar Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar Expanded barcodes.
Symbologies 146 QuickScan® QD2100 GS1 DataBar Expanded — cont. GS1 DataBar Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Ex- panded label must be decoded before it is accepted as good read .
GS1 DataBar Expanded Product Reference Guide 147 GS1 DataBar Expanded — cont. GS1 DataBar Expanded L ength C ontrol This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology. Variable Length — For variable-length decoding, a minimum length may be set.
Symbologies 148 QuickScan® QD2100 GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set L ength 1 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Lengt h Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
GS1 DataBar Expanded Product Reference Guide 149 GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Symbologies 150 QuickScan® QD2100 GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set L ength 2 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Lengt h Control . Length 2 is the maximum label length if in Variable Length Mode, or the sec- ond fixed length if in Fixed Length Mode.
GS1 DataBar Expanded Product Reference Guide 151 GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Symbologies 152 QuickScan® QD2100 GS1 DataBar Limited The following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym- bology. GS1 DataBar Limited Enable/Disable When disabled, the reader will not read GS1 DataBar Limited barcodes.
GS1 DataBar Limited Product Reference Guide 153 GS1 DataBar Limited — cont. GS1 DataBar Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read .
Symbologies 154 QuickScan® QD2100 Co d e 3 9 The following options apply to the Code 39 symbology. C ode 39 Enable/Disable When disabled, the reader will not read Code 39 barcodes.
Code 39 Product Reference Guide 155 Code 39 — cont. C ode 39 Check Char acter Calcula tion Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character.
Symbologies 156 QuickScan® QD2100 Code 39 — cont. C ode 39 Check Character T ransmission Enable this option to transmit the check character along with Code 39 barcode data. C ode 39 Star t/Stop Character T ransmission Enable this option to enable/disable transmission of Code 39 start and stop characters.
Code 39 Product Reference Guide 157 Code 39 — cont. Co d e 3 9 Fu l l A S C I I In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
Symbologies 158 QuickScan® QD2100 Code 39 — cont. Co d e 3 9 Q u i e t Z o n e s This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
Code 39 Product Reference Guide 159 Code 39 — cont. C ode 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.
Symbologies 160 QuickScan® QD2100 Code 39 — cont. C ode 39 Decoding L ev el Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Code 39 Product Reference Guide 161 Code 39 — cont. Code 39 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Lev el = 1 Code 39 Decoding Le vel = 2 Code 39 Decoding Lev el = 3 C.
Symbologies 162 QuickScan® QD2100 Code 39 — cont. Co d e 3 9 L e n g t h Co n t r o l This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Code 39 Product Reference Guide 163 Code 39 — cont. C ode 39 Set Length 1 This feature specifies one of the barcode lengths for Code 39 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Symbologies 164 QuickScan® QD2100 Code 39 — cont. Code 39 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Code 39 Product Reference Guide 165 Code 39 — cont. C ode 39 Set Length 2 This feature specifies one of the barcode lengths for Code 39 Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Symbologies 166 QuickScan® QD2100 Code 39 — cont. Code 39 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Code 39 Product Reference Guide 167 Code 39 — cont. C ode 39 Inter digit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels.
Symbologies 168 QuickScan® QD2100 Code 39 — cont. Code 39 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio =.
Code 39 Product Reference Guide 169 Code 39 — cont. Co d e 3 9 C h a ra c t e r Co r r e l a t i o n When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 170 QuickScan® QD2100 Co d e 3 9 S t i t c h i n g This option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar- code are presented to the reader with this featu.
Code 32 Product Reference Guide 171 Co d e 3 2 The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology. C ode 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes.
Symbologies 172 QuickScan® QD2100 Code 32 — cont. C ode 32 Check Character T ransmission Enable this option to transmit the check character along with Code 32 barcode data. C ode 32 Star t/Stop Character T ransmission This option enables/disable transmission of Code 32 start and stop characters.
Code 128 Product Reference Guide 173 C ode 128 The following options apply to the Code 128 symbology. C ode 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. Expand C ode 128 to C ode 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Symbologies 174 QuickScan® QD2100 Code 128 — cont. C ode 128 Check Character T ransmission Enable this option to transmit the check character along with Code 128 barcode data. C ode 128 F unc tion Charac ter T ransmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Code 128 Product Reference Guide 175 Code 128 — cont. C ode 128 Sub-C ode Change T ransmission Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding).
Symbologies 176 QuickScan® QD2100 Code 128 — cont. C ode 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
Code 128 Product Reference Guide 177 Code 128 — cont. C ode 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.
Symbologies 178 QuickScan® QD2100 Code 128 — cont. C ode 128 Decoding L ev el Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Code 128 Product Reference Guide 179 Code 128 — cont. Code 128 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Lev el = 1 Code 128 Decoding Le vel = 2 Code 128 Decoding Lev el.
Symbologies 180 QuickScan® QD2100 Code 128 — cont. C ode 128 Length C ontrol This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Code 128 Product Reference Guide 181 Code 128 — cont. C ode 128 Set Length 1 This feature specifies one of the barcode lengths for Code 128 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Symbologies 182 QuickScan® QD2100 Code 128 — cont. Code 128 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Code 128 Product Reference Guide 183 Code 128 — cont. C ode 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Symbologies 184 QuickScan® QD2100 Code 128 — cont. Code 128 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Code 128 Product Reference Guide 185 Code 128 — cont. C ode 128 Character C orrelation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 186 QuickScan® QD2100 Code 128 — cont. C ode 128 Stitching This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with .
GS1-128 Product Reference Guide 187 GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format.
Symbologies 188 QuickScan® QD2100 Interlea v ed 2 of 5 (I 2 of 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 189 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character . When disabled, any check character in label is treated as a data character.
Symbologies 190 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character T ransmission Enable this option to transmit the check character along with I 2 of 5 barcode data.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 191 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read.
Symbologies 192 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Le vel Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 193 Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Le vel = 1 2 of 5 Decoding.
Symbologies 194 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Length C ontrol This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 195 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Symbologies 196 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 197 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Symbologies 198 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 199 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Character C orrelation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 200 QuickScan® QD2100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels.
Datalogic 2 of 5 Product Reference Guide 201 Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes.
Symbologies 202 QuickScan® QD2100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Check Character C alculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character.
Datalogic 2 of 5 Product Reference Guide 203 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 la- bel must be decoded before it is accepted as good read.
Symbologies 204 QuickScan® QD2100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 L ength Con trol This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Datalogic 2 of 5 Product Reference Guide 205 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Symbologies 206 QuickScan® QD2100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Datalogic 2 of 5 Product Reference Guide 207 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control . Length 2 is the maximum label le ngth if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Symbologies 208 QuickScan® QD2100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Datalogic 2 of 5 Product Reference Guide 209 Datalogic 2 of 5 Interdigit Maximum Ra tio This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5.
Symbologies 210 QuickScan® QD2100 Datalogic 2 of 5 Interdigit Maximum Ratio — cont. Datalogic 2 of 5 Interdigit Maximum Ratio = 6 Datalogic 2 of 5 Interdigit Maximum Ratio = 7 Datalogic 2 of 5 Inte.
Datalogic 2 of 5 Product Reference Guide 211 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Char ac ter C orr elation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 212 QuickScan® QD2100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Stit ching This option enables/disables stitching for Datalogic 2 of 5 labels.
Codabar Product Reference Guide 213 C odabar The following options apply to the Codabar symbology. C odabar Enable/Disable When disabled, the reader will not read Codabar barcodes.
Symbologies 214 QuickScan® QD2100 Codabar — cont. C odabar Check Char acter Calcula tion Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check characters in the label are treated as data characters.
Codabar Product Reference Guide 215 Codabar — cont. C odabar Check Character T ransmission Enable this option to transmit the check character along with Codabar barcode data. C odabar Start/Stop Char acter T ran smission Enable this option to enable/disable transmission of Codabar start and stop characters.
Symbologies 216 QuickScan® QD2100 Codabar — cont. C odabar Start/Stop Char acter Set This option specifies the format of transmitted Codabar start/stop characters .
Codabar Product Reference Guide 217 Codabar — cont. C odabar Start/Stop Char ac ter Ma tch When enabled, this option requires that start and stop characters match.
Symbologies 218 QuickScan® QD2100 Codabar — cont. Co d a b a r Q u i e t Z o n e s This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
Codabar Product Reference Guide 219 Codabar — cont. C odabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read.
Symbologies 220 QuickScan® QD2100 Codabar — cont. C odabar Decoding L ev el Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Codabar Product Reference Guide 221 Codabar — cont. Codabar Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Lev el = 1 Codabar Decoding Lev el = 2 Codabar Decoding Lev el = 3 C.
Symbologies 222 QuickScan® QD2100 Codabar — cont. Co d a b a r L e n g t h Co nt r o l This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Codabar Product Reference Guide 223 Codabar — cont. C odabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Symbologies 224 QuickScan® QD2100 Codabar — cont. Codabar Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Codabar Product Reference Guide 225 Codabar — cont. C odabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Symbologies 226 QuickScan® QD2100 Codabar — cont. Codabar Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Codabar Product Reference Guide 227 Codabar — cont. C odabar Inter digit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels.
Symbologies 228 QuickScan® QD2100 Codabar — cont. Codabar Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio =.
Codabar Product Reference Guide 229 Codabar — cont. Co d a b a r C h a ra c t e r Co r r e l a t i o n When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Symbologies 230 QuickScan® QD2100 C odabar Stitching This option enables/disables stitching for Codabar labels. When parts of a Codabar bar- code are presented to the reader with this feature enabled, the barcode parts will be as- sembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
Code 11 Product Reference Guide 231 Co d e 1 1 The following options apply to the Code 11 symbology. C ode 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes.
Symbologies 232 QuickScan® QD2100 Code 11 — cont. C ode 11 Check Char acter Calcula tion This option enables/disables calculation and verification of optional Code 11 check char- acter.
Code 11 Product Reference Guide 233 Code 11 — cont. C ode 11 Check Character T ransmission This feature enables/disables transmission of an optional Code 11 check character.
Symbologies 234 QuickScan® QD2100 Code 11 — cont. C ode 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.
Code 11 Product Reference Guide 235 Code 11 — cont. Co d e 1 1 L e n g t h Co n t r o l This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Symbologies 236 QuickScan® QD2100 Code 11 — cont. C ode 11 Set Length 1 This feature specifies one of the barcode lengths for Code 11 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Code 11 Product Reference Guide 237 Code 11 — cont. Code 11 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Symbologies 238 QuickScan® QD2100 Code 11 — cont. C ode 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11 Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Code 11 Product Reference Guide 239 Code 11 — cont. Code 11 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing. Y ou can then star t again at the beginning.
Symbologies 240 QuickScan® QD2100 Code 11 — cont. C ode 11 Inter digit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels.
Code 11 Product Reference Guide 241 Code 11 — cont. Code 11 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Interdigit Ratio .
Symbologies 242 QuickScan® QD2100 C ode 11 Decoding L ev el Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Code 11 Product Reference Guide 243 Code 11 — cont. Code 11 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Lev el = 1 Codabar Decoding Lev el = 2 Codabar Decoding Lev el = 3 C.
Symbologies 244 QuickScan® QD2100 Code 11 — cont. Co d e 1 1 C h a ra c t e r Co r r e l a t i o n When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Code 11 Product Reference Guide 245 Co d e 1 1 S t i t c h i n g This option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar- code are presented to the reader with this feat.
Symbologies 246 QuickScan® QD2100 Standa rd 2 of 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes.
Standard 2 of 5 Product Reference Guide 247 Standard 2 of 5 — cont. Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
Symbologies 248 QuickScan® QD2100 Standard 2 of 5 — cont. Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.
Standard 2 of 5 Product Reference Guide 249 Standard 2 of 5 — cont. Standard 2 of 5 Length C o ntrol This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
Symbologies 250 QuickScan® QD2100 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Standard 2 of 5 Product Reference Guide 251 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Symbologies 252 QuickScan® QD2100 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control . Length 2 is the maximum labe l length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Standard 2 of 5 Product Reference Guide 253 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistak e? Scan the CANCEL barcode to abor t and not sav e the entry str ing.
Symbologies 254 QuickScan® QD2100 Standard 2 of 5 — cont. Standard 2 of 5 Char acter Corr elation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
Standard 2 of 5 Product Reference Guide 255 Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Stan- dard 2 of 5 barcode are presented to the .
Symbologies 256 QuickScan® QD2100 ISB T 128 The following options apply to the ISBT 128 symbology. ISB T 128 Enable/Disable Enables/Disables ability of imager to decode ISBT 128 labels. ISB T 128 Conca tenation Enables/disables ISBT128 concatenation of 2 labels.
ISBT 128 Product Reference Guide 257 ISBT 128 — cont. ISBT 128 F orce C oncatena tion When enabled, this feature forces all ISBT 128 labels to be concatenated. ISB T 128 Adv anced C oncatenation Options NO TE This option is only valid when ISBT 128 Concatenation is enabled.
Symbologies 258 QuickScan® QD2100 Co d e 4 The following options apply to the Code 4 symbology. C ode 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels.
Code 4 Product Reference Guide 259 Code 4 — cont. C ode 4 Check Chara c ter T ransmission This feature enables/disables transmission of an optional Code 4 check character. C ode 4 He x to Decimal Co nv ersion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ta.
Symbologies 260 QuickScan® QD2100 Co d e 5 The following options apply to the Code 5 symbology. C ode 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels.
Code 5 Product Reference Guide 261 Code 5 — cont. C ode 5 Check Chara c ter T ransmission This feature enables/disables transmission of an optional Code 5 check character. C ode 5 He x to Decimal Co nv ersion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ta.
Symbologies 262 QuickScan® QD2100 Co d e 4 a n d Co d e 5 Co m m o n Co n f i g u r a t i o n I t e m s The following options apply to both Code 4 and Code 5 symbologies.
Code 4 and Code 5 Common Configuration Items Product Reference Guide 263 Code 4 and Code 5 Common Configuration Items — cont. Code 4 and 5 Decoding Level — cont.
Symbologies 264 QuickScan® QD2100 Code 4 and Code 5 Common Configuration Items — cont. C ode 4 and C ode 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.
Follett 2 of 5 Product Reference Guide 265 Fo l l e t t 2 o f 5 The following options apply to the Follett 2 of 5 symbology. F ollett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels.
Symbologies 266 QuickScan® QD2100 NO TES.
Product Reference Guide 267 Appendix A T echnical Specifications Table 35 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 36 provides Standard Cable Pinouts. T able 35. T echnical Specifica tions Item Description Physical Characteristics Dimensions 2.
268 QuickScan® QD2100 Decode Capability UPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII; Code 32 (Italian Pharmacode); Code 128; ISBT 128; I 2 of 5; Standard 2 of 5; Code 11; Codabar.
Standard Cable Pinouts Product Reference Guide 269 Standard C able Pinouts Figure 7 and Table 36 provide standard pinout information for the imager’s cable. Figure 7 . St and ard Ca ble Pin out s The signal descriptions in Table 36 apply to the connector on the imager and are for ref- erence only.
270 QuickScan® QD2100 NO TES.
Product Reference Guide 271 Appendix B Standar d Defaults The most common configuration settings are listed in the “Default” column of Table 37 . The settings in this table are as applied to a standard RS-232 interface. See Table 38 for a listing of default exceptions to this list as appled to other interface types.
272 QuickScan® QD2100 RS-232 Baud Rate 9600 41 Data Bits 8 Data Bits 43 Stop Bits 1 Stop Bit 44 Pa r i t y None 45 Handshakin g Control Disab le 46 RS-232/USB-COM Intercharacter Dela y No Delay 48 Be.
Product Reference Guide 273 Data Editing Global Prefix/Suffix No Global Prefix Global Suffix = 0x0D (CR) 90 Global AIM ID Disab le 92 Label ID Control Disable 100 Case Conv ersion Disab le 107 Charact.
274 QuickScan® QD2100 EAN-13 ISBN Conv ersion Disable 122 EAN 13 Minimum Reads 1 123 EAN 8 EAN 8 Enable/Disab le Enab le 124 EAN 8 Check Character T ransmission Send 124 Expand EAN 8 to EAN 13 Disabl.
Product Reference Guide 275 GS1 DataBar Expand ed Set Length 1 1 148 GS1 DataBar Expand ed Set Length 2 74 150 GS1 DataBar Limited GS1 DataBar Limited Enable/Disab le Disab le 152 GS1 DataBar Limited .
276 QuickScan® QD2100 Expand Code 128 to Code 39 Don’t Expand 173 Code 128 Check Character T ransmission Send 174 Code 128 Quiet Zones Aut o 17 6 Code 128 Minimum Reads 1 177 Code 128 Decoding Le v.
Product Reference Guide 277 Datalogic 2 of 5 Set Length 1 12 205 Datalogic 2 of 5 Set Length 2 100 207 Datalogic 2 of 5 Ch ar acter Correlation Disable 211 Datalogic 2 of 5 Stitching Disab le 212 Coda.
278 QuickScan® QD2100 Code 11 Interdigit Ratio 4 240 Code 11 Decoding Lev el 3 242 Code 11 Character Correlation Disable 244 Code 11 Stitching Disable 245 Standard 2 of 5 Standard 2 of 5 Enable/ Disa.
Product Reference Guide 279 Code 4 and Code 5 Common Configuration Items Code 4 and 5 Decoding Le vel 3 262 Code 4 and Code 5 Minimum Reads 1 264 Follett 2 of 5 Fo llett 2 of 5 Enable/Disab le Disable.
280 QuickScan® QD2100 Default Ex ceptions Table 37 lists standard default settings as applied to a standard RS-232 interface. Table 38 provides a listing of default exceptions to that list as applied to the other inter- face types.
Default Exceptions Product Reference Guide 281 EAN8/P2 Label ID Character(s) B EAN8/P5 Label ID Character(s) B EAN8/GS1-128 Label ID Character(s) B EAN13/P2 Label ID Character(s) A EAN13/P5 Label ID C.
282 QuickScan® QD2100 UPCE/P5 Label ID Character(s) I EAN8/P2 Label ID Character(s) J EAN8/P5 Label ID Character(s) K EAN8/GS1-128 Label ID Character(s) * EAN13/P2 Label ID Character(s) L EAN13/P5 La.
Product Reference Guide 283 Appendix C LED and Beeper Indications The imager’s beeper sounds and its LED illuminates to indicate various functions or er- rors on the imager. An optional “Green Spot” also performs useful functions. The tables below list these indications.
284 QuickScan® QD2100 LED and Beeper Indications INDICA TION DESCRIPTION LED BEEPER P ower-up Beep The imager is in the process of pow- ering-up. Imager beeps four times at highest frequency and v olume upon power- up . Good Read Beep A label has been successfully scanned by the imager .
Error Codes Product Reference Guide 285 Error C o des Upon startup, if the imager sounds a long tone, this means the imager has not passed its automatic Selftest and has entered FRU 1 isolation mode. If the imager is reset, the se- quence will be repeated.
286 QuickScan® QD2100 NO TES.
Product Reference Guide 287 A ppendix D Samp le B ar c o des The sample barcodes in this appendix are typical representations for their symbology types.
288 QuickScan® QD2100 Sample Barcodes — continued Code 32 Codabar Code 93 Code 11.
GS1 DataBar (RSS) Product Reference Guide 289 GS1 DataBar (RSS) GS1 DataBar-14 NO TE GS1 DataBar variants m ust be enabled to read the bar codes below (see GS1 DataBar (RSS) on page 289 ).
290 QuickScan® QD2100 NO TES.
Product Reference Guide 291 Appendix E Key p a d Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.
292 QuickScan® QD2100 6 7 8 9 A B C.
Product Reference Guide 293 D E F.
294 QuickScan® QD2100 NO TES.
Product Reference Guide 295 Appendix F Scanc ode T ables C ontrol Char acter Emulation Control character emulation selects from different scancode tables as listed in this appen- dix. Each of the control character sets below are detailed by interface type in the tables.
Product Referenc e Guide 296 Inter face T ype PC A T PS/2 or USB-Ke yboard Table 39. Scancode Set When Control Character is 00 or 01 Extended characters (sky b lue) are sent via dedicated ke ys (when av ailable in the selected country mode) or by an Alt Mode sequ ence .
Product Referenc e Guide 297 Interface Type PC AT PS/2 or USB-Keyboard — cont. Table 40. Scancode Set When Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar È Ar Ç Al .
Product Referenc e Guide 298 Inter face type PC A T PS/2 Alt Mode or USB-K e yboard Alt Mode Table 41. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE Xf 0.
Product Referenc e Guide 299 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont. Table 42. Scancode Set When Control Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0.
Product Referenc e Guide 300 Digital Inter face Table 43. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x NULL C(S)+@ SOH C(S)+A STX C(S)+B ETX C(S)+.
Product Referenc e Guide 301 Digital Interface — cont. Table 44. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl È Cl Ç BS Ta b Æ S+ T ab Enter Keypd Enter Ins 1x Å È Ç F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x S p a c e ! “ # $ % & ‘() * + , - .
Product Referenc e Guide 302 IBM31xx 102-ke y Table 45. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x NULL C(S)+@ SOH C(S)+A STX C(S)+B ETX C(S)+C .
Product Referenc e Guide 303 IBM31xx 102-key — cont. Table 46. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar È Ar Ç Al È Al Ç Cl È Cl Ç Cr È .
Product Referenc e Guide 304 IBM XT Table 47. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x NULL C(S)+@ SOH C(S)+A STX C(S)+B ETX C(S)+C EOT C+D EN.
Product Referenc e Guide 305 IBM XT — cont. Table 48. Scancode Set When Control Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar È Ar Ç Al È Al Ç Cl È Cl Ç Cr È Cr Ç BS .
306 QuickScan® QD2100 Microsof t Windo ws C odepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg- acy components of Microsoft Windows in English and some other Western languages.
Microsoft Windows Codepage 1 252 Product Reference Guide 307 NO TES.
308 QuickScan® QD2100 NO TES.
Product Reference Guide 309 Inde x B bar codes RS-232 baud rate 79 RS-232 parameters parity 256 , 258 , 260 , 263 , 265 barcodes cancel 291 numeric barcodes 291 RS-232 parameters parity 70 Beeper Pitc.
310 QuickScan® QD2100 N numbers lock key 71 P Performance Characteristics 267 Physical Characteristics 267 Pitch – Good Read, Beeper 23 , 24 Pitch Tolerance 267 Prefix/Suffix 90 Print Contrast Mini.
ASCII Char t ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . He x No . NUL SOH STX ETX EO T ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SU.
A ustralia Datalogic Scanning Pty Ltd T elephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Fra n c e a n d B e n e l u x Datalogic Scanning Sarl T elephone: [33].01.64.86.71.00 france .scanning@datalogic.com Germ an y Datalogic Scanning GmbH T elephone: 49 (0) 61 51/93 58-0 germany .
Een belangrijk punt na aankoop van elk apparaat Datalogic Scanning QD2100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Datalogic Scanning QD2100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Datalogic Scanning QD2100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Datalogic Scanning QD2100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Datalogic Scanning QD2100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Datalogic Scanning QD2100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Datalogic Scanning QD2100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Datalogic Scanning QD2100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.