D A TEL, Inc., Mansfield, MA 02048 (USA) · T el: (508)339-3000, (800)233-2765 F ax: (508)339-6356 · Email: sales@datel.com · Inter net: www.datel.com –V IN (1) +V IN (3) OPTO ISOLA TION PWM CONT.
USQ Series USQ-1.2/20-D48 1.2 20 25 50 ±0.05% ±0.05% 48 36-75 0.63/0.87 80% C33, P32 USQ-1.5/20-D48 1.5 20 40 65 ±0.05% ±0.05% 48 36-75 0.75/1.03 85% C33, P32 USQ-1.8/20-D48 1.8 20 50 80 ±0.05% ±0.05% 48 36-75 0.88/1.23 85% C33, P32 USQ-2.5/20-D48 2.
USQ Models Remote On/Off Control P olarity: Add "P" for positiv e polarity (pin 2 open = conv er ter on) Add "N" for negativ e polarity (pin 2 open = conv er ter off) P erformance/Functional Specifications T ypical @ T A = +25°C under nominal line voltage and full-load conditions , unless noted.
USQ Series 4 Remov al of Soldered USQ's from PCB's Should remov al of the USQ from its soldered connection be needed, it is very impor tant to thoroughly de-solder the pins using solder wic ks or de-soldering tools. At no time should an y prying or lev erage be used to remov e boards that hav e not been properly de-soldered first.
USQ Models 5 On/Off Control The primar y-side, Remote On/Off Control function (pin 2) can be specified to operate with either positiv e or negative polarity . P ositive-polarity devices ("P" suffix) are enabled when pin 2 is left open or is pulled high (+2.
USQ Series LOAD R TRIM DOWN +OUTPUT –INPUT +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 7 2 LOAD R TRIM UP +OUTPUT –INPUT +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 7 2 Figure 5. T rim Connections T o Increase Output V oltages Using Fixed Resistors Figure 6.
USQ Models 7 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 6 1 x 10 5 1 x 10 4 1 x 10 3 Figure 7. USQ-1.2 T rim-Up Resistance vs. % Increase V OUT 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 7 1 x 10 6 1 x 10 5 1 x 10 3 1 x 10 4 Figure 8.
USQ Series 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 8 1 x 10 7 1 x 10 6 1 x 10 5 Figure 13. USQ-12 T rim-Up Resistance vs. % Increase V OUT 0 1 2 3 4 5 6 7 8 9 10 V OUT INCREASE (%) RESIST ANCE 1 x 10 8 1 x 10 7 1 x 10 6 1 x 10 5 Figure 14.
USQ Models LOAD +OUTPUT –INPUT Sense Current Contact and PCB resistance losses due to IR drops Contact and PCB resistance losses due to IR drops Sense Retur n +INPUT ON/OFF CONTROL TRIM +SENSE –OUTPUT –SENSE 4 5 1 3 6 8 I OUT Return I OUT 7 2 Remote Sense Note: The Sense and V OUT lines are not inter nally connected to each other .
USQ Series Load Conditions ➀ Performance Specifications 1.2V OUT 1.5V OUT 1.8V OUT 2.5V OUT 3.3V OUT 5V OUT 12 to 24V OUT Load Step = 50 to 75% of I OUT Max.: P eak Deviation, typ . 115mV 110mV 125mV 100mV 170mV 125mV 100mV Settling Time to ±1% of Final V alue, max.
USQ Models T ypical P erformance Curves f or 1.2V OUT Models 90 85 80 75 70 65 60 USQ-1.2/20-D48 Efficiency vs. Line V oltage and Load Current 2 4 6 8 10 12 14 16 18 20 Load Current (Amps ) Efficiency ( % ) V IN = 36V V IN = 48V V IN = 75V Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.
USQ Series T ypical P erformance Curves f or 1.5V OUT Models .
USQ Models T ypical P erformance Curves f or 1.8V OUT Models .
USQ Series T ypical P erformance Curves f or 2.5V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 1V/div 20V/div 2.5V OUT (pin 8) +Input (pin 3) Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.
USQ Models T ypical P erformance Curves f or 3.3V OUT Models .
USQ Series T ypical P erformance Curves f or 5V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 20A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 1V/div 20V/div 5V OUT (pin 8) +Input (pin 3).
USQ Models T ypical P erformance Curves f or 5V OUT Models .
USQ Series T ypical P erformance Curves f or 12V OUT Models Start-Up from V IN (V IN = 48V , I OUT = 8.3A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 5V/div 20V/div 12V OUT (pin 8) +Input (pin 3) 95 90 85 80 75 70 65 60 55 USQ-12/8.3-D48 Efficiency vs.
USQ Models Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 8.3A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 5V/div 2V/div 12V OUT (pin 8) Remote On/Off Control (pin 2) USQ-12/8.3-D24: Output Current vs. Ambient T emperature (T ransverse air flow , pin 1 to pin 3; V IN = 24V , 1/2" heat sink.
USQ Series T ypical P erformance Curves f or 15V OUT Models 20 .
USQ Models 21 T ypical P erformance Curves f or 24V OUT Models Start-Up from Remote On/Off Control (V IN = 48V , I OUT = 4.2A, C OUT = 10µF tantalum || 1µF ceramic.) 2msec/div 10V/div 2V/div 24V OUT (pin 8) Remote On/Off Control (pin 2) Start-Up from V IN (V IN = 48V , I OUT = 4.
DS-0493D 10/04 BO TT OM VIEW –Input Remote On/Off +Input +Output +Sense Output T rim –Sense –Output Figure 20. Industry Standard Quarter-Brick Pinout Figure 20 readily allows users to confirm that DA TEL quar ter-brick DC/DC conv er ters are compatib le to the industry-standard pinout, independent of pin-numbering conv entions.
Een belangrijk punt na aankoop van elk apparaat Datel 20A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Datel 20A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Datel 20A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Datel 20A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Datel 20A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Datel 20A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Datel 20A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Datel 20A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.