THE PROFESSIONAL EUR O HOOD Use and Installation Guide Models: ■ EH-30SS ■ EH-36SS Dyn a m i c C o o k i n g S y s t e m s, In c..
1 A M e s s a g e T o Ou r C u s t o m e r s Thank you for selecting this DCS Updr aft Euro Hood. Because of its unique featur es , we have developed this Use and Installation Guide . It contains valuable information on how to pr operly operate and maintain your ne w Updraft Eur o Hood for y ear s of safe and enjo yable cooking.
2 T ab le O f Content s SAFETY PRA CTICES & PRECA UTIONS ...............................................................................3 SPECIFICA TIONS .............................................................................................
3 S afety P ractice s & P recautions This eur o hood system is designed to remov e smoke, cooking vapors and odors from the cooktop area. W ARNING: ALL WALL AND FLOOR OPENINGS WHERE THE EURO HOOD IS INST ALLED MUST BE SEALED . Consult the cooktop or range installation instructions given b y the manufacturer bef ore making any cutouts.
4 S pecif ication s 7 1/2" 8 3/4" 14 7/8" 9 7/16" 40" max. 20 7/8" to min. 29 7/8" - 30" Hood 35 7/8" - 36" Hood 19 1/2" 10 5/16" FIG .01Hood with optional Chimney 4" 5 7/8" 2 15/16" 4 5/16" 11/16" 9 7/8" 12 5/8" 25 1/4" FIG .
5 P lanning T he I ns tallation VENTING REQUIREMENTS Determine which venting method is best f or your application. Ductwork can extend either thr ough the wall or the r oof. The length of the ductwork and the n umber of elbows should be k ept to a mini- mum to pr ovide efficient performance.
6 I n s tallation I ns t ruction s T OOLS NEEDED FOR INST ALLA TION P AR TS SUPPLIED FOR INST ALLA TION • Saber Sa w or Jig Sa w • 1 Hardwar e Package • Drill • 1 Literature Package • 1 1/4 .
I n s tallation I n s truction s 7 cabinet base 30" or 36" 10 5/16" 30" 36" FIG .05A STAND ARD INST ALLATION DIMENSIONS (FRONT VIEW).
I n s tallation I n s truction s 8 Upper Chimney Cover cabinet base Lower Chimney Cover Max. = 9' 8 5/16" (116 5/16" ) Min. = 8' 2 3/16" (98 3/16" ) 19 1/2 " min 21 7/8" max 40" 10 5/16" 30" 36" FIG .
CALCULA TE THE DUCT R UN LENGTH The duct run should not exceed 35 feet if ducted six inch (6”) r ound ductwork. Calculate the length of the ductwork b y adding the equivalent feet in fig. 06 for each piece of duct in the system an example is given in fig.
10 5) Determine and mak e all necessar y cuts in the wall for the ductwork. Each euro hood is shipped fr om the factor y vented thr ough the top. In order to v ent to the rear , ductwork must run first vertical then elbow to the back. The dimensions for the duct openings ar e given in Fig.
11 I n s tallation I n s truction s 7) The brack ets shown in Fig. 08 are also used to adjust the le vel of the canop y . Using a Phillips scre wdriver , r otate the screw V2 to adjust the level of the canop y . 8) Connect the P ower Supply Cable to the eur o hood.
12 U s e & C a r e In f ormation CONTROL P ANEL The contr ol panel is located on the right-hand side under the canopy . LIGHT ON/OFF SWITCH ( A ) On/Off switch for the halogen light. Mov e the switch to "1" to turn the light ON and to "0" to turn it OFF .
W iring D iagram 30” & 36” H o o d s 13.
14 S e rvice HO W T O OBT AIN SER VICE: Befor e you call for service: 1) Is the cir cuit break er tripped or the fuse blown? 2) Is there a po wer outage in the ar ea? For war ranty ser vice , contact y our local DCS authorized ser vice agency .
15 Wa r ranty LENGTH OF W ARRANTY One (1) Y ear Full parts and Labor Covers the entir e product Five (5) Y ear Limited warranty cov ering the switches and motor . DCS WILL P A Y FOR All repair labor and parts found to be defectiv e due to materials or workmanship for one full y ear “IN HOME” warranty during the first y ear of ownership.
No te s 16.
Part No. 17386 Rev . A Litho in USA 06/2001 As product impr ovement is an ong oing process at DCS, we reser ve the r ight to change specifications or design without notice . 5800 Skylab Road, Huntington Beach, CA. 92647 T el: (714) 372-7000 Fax: (714) 372-7001 Parts/Customer Service (888) 281-5698 www .
Een belangrijk punt na aankoop van elk apparaat DCS EH-36SS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen DCS EH-36SS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens DCS EH-36SS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding DCS EH-36SS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over DCS EH-36SS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van DCS EH-36SS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de DCS EH-36SS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met DCS EH-36SS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.