Victor Teeter Network Enabled Solutions Team Stacking Dell For ce10 MXL 10/40G Blade Switches.
Stacking Dell Force10 MXL 10/ 40G Blade Switches v1.1 ii This document is f or informational pu rposes only and may cont ain typographical er rors and technical inaccuracies . The content is p rovided as is, withou t express or implied war ranties of any kind.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 1 Contents Introduction ................................ ............................................................................. 3 Redundancy ........................................
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 2.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 3 Introduction Numerous Dell ™ swi tches include a sta cking feature t hat allows multiple physica l switches to operate as a single logical s witch, p roviding a consolidated int erface for manag ement .
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 4 Additional stack mem bers can immedia tely utilize existing co nfiguration informatio n such as routing and switching configurati ons, VLANs, ACLs , port profil es, and security ce rtificates.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 5 Another way to comp letely wipe out a ll configurations and r eturn to factory def aults is to erase the meta-data (NVRAM) a nd delete th e startup configura tion by following th e instructions i n Restoring factory defaults be low.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 6 no ip address shutdown ! interface TenGigabit Ethernet 0/2 no ip address -- More -- Additional stack -unit lines like t he one below may be fo und in an unstacked MX L if one or more expansion mod ules are present.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 7 Port numbering When installed in a Pow erEdge ™ M1000e Enclosure, th e MXL 10/40GbE external swi tch ports are numbered 33 to 56 from.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 8 Combining split 10GbE SFP+ ports into a single 40GbE QSFP+ p ort The MXL 10/40GbE Swit ch supports splittin g each 40G bE port on the base module or a 2 -Port 40GbE QSFP+ expansion mo dule into eight 10GbE SFP+ ports using a break out cable.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 9 listed here whe n in port mode. If there is no “sta ck - unit” listing for t he first port number, then the po rts are not split and ar e running at 4 0 GbE.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 10 Status : on line Next Boot : online Required Type : MXL -10/4 0GbE - 34 -port GE/TE/FG (X L) Current Type : MXL-10/40GbE - 34 -port GE/TE/FG (XL) Master priority : 0 Hardware Rev : X00 Num Ports : 56 Up Time : 1 wk , 3 day, 23 hr , 5 min FTOS Version : 8.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 11 QSFP+ built-in ports a re set to 40 Gb by default whi le expansion mo dule QSFP+ p orts are set to 10 Gb ports by default.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 12 Stacking multip le M XL swit ches in a single M1 000e Figure 5. Dell M1000e Blade Chassis B2 C2 A2 B1 C1 A1 4 1 7 5 2 8 6 3 9 CMC2 CMC.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 13 The Dell M1000e Se rver Chassi s includes a manag ement console port on the CMC tha t allows a llows management of eac h module from a s ingle serial conn ection to the chassis. Fo r more information , see the Dell Blade Se rver CMC User 's Guide at http://support.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 14 FTOS# show invento ry optional- module Unit Slot Expecte d Inserted N ext Boot Power ------ ----- ------- -------- ------------- -----.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 15 Note: When creating s tack ports on an MXL, all ports must be fixed or on the ex pansion module. Mixi ng fixed and expansion mod ule ports in o rder to stack is not supported. Maximum st ack-group per unit A maximum of 4 stack-groups per unit can be configured.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 16 1 Standby o nline MXL - 10/40G bE MXL-10/40GbE 8 .3.16.0E0 56 2 Member on line MXL -10/40GbE MXL -10/40GbE 8 .3.16.0E0 56 3 Member on line MXL -10/40GbE MX L-10/40GbE 8 .3.16.0E0 56 4 Member on line MXL -10/40GbE MXL -10/40GbE 8 .
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 17 FTOS(conf)# sta ck-unit 1 provision ? MXL-10/40GbE 34-po rt GE/TE/FG (XL) FTOS(conf)# sta ck-unit 1 provision MXL -10/40GbE Certain configurati on changes on th e unit suc h as “fanout” and “stack - grou ps” may require sav ing and reloading the e ntire stack.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 18 the downloaded image is distributed to all mem ber units of the stack . The inst ructions below wi ll guide the user thro ugh these steps.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 19 Image upgraded to a ll 4. Verify the new firmware w as copied to all sta ck members. FTOS# show boot syste m stack- unit all Current s.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 20 FTOS# show boot syste m stack- unit all Current system ima ge information in th e system: =========== ======= ========== ================= Type Boot Typ e A B ------ ----- ------- -------- ----- -------- ----- ------- -------- ----- Stack-unit 0 FLASH BOOT 8.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 21 FTOS(conf)# no sta ck-unit 2 st ack-group 0 FTOS(conf)# no sta ck-unit 2 st ack-group 1 FTOS(conf)# no sta ck-unit 2 st ack-group 2 FT.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 22 FTOS# stack-unit 1 renumber 5 % ERROR: stack unit 5 already exis ts. If the new number a ssign ment is already used b y a logi cally provisi oned u nit in the stack, t he be low confirmation message to overwrite is dis played.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 23 Appendix A – Sta cking scenarios When creating s tack ports o n an MXL, all ports must be fixed or on the expansio n module. Mixing fix ed and expansion mod ule ports i n order to stack is not su pported.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 24 Appendix B – Port mapping.
S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 25 Appendix C - Net work switch vers ions Version information for t he network switc hes used i n creating this docum ent are as f ollows: Network switch Dell Force10 XML Software version 8.
Een belangrijk punt na aankoop van elk apparaat Dell MXL 10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dell MXL 10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dell MXL 10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dell MXL 10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dell MXL 10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dell MXL 10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dell MXL 10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dell MXL 10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.