INSTRUCTIO N M AN UAL P ART NO. D26316 Rev .0 Copyright © 2002 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .
2- ENG D26316 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG D26316 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG D26316 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG D26316 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: Risk to Br eathing WARNING: Risk of Electrical Shock HOW TO PREVENT IT WHA T CAN HAPPEN HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used pr operly it may cause electric shock.
6- ENG D26316 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: RISK OF BURNS T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation.
7- ENG D26316 Review and understand all instructions and war nings in this manual. Become familiar with the operation and controls of the air compr essor . Keep operating area clear of all persons, pets, and obstacles. Keep children away fr om the air compressor at all times .
8- ENG D26316 GLOSSAR Y Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure.
INST ALLA TION Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated ar ea. The air compressor should be located at least 12" away fr om the wall or other obstructions that will interfere with the flow of air .
10- ENG D26316 V oltage and Circuit Pr otection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp cir cuit if the following conditions are met. 1. V oltage supply is 108V -132V AC at the outlet.
11- ENG D26316 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compar e the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for futur e refer ence.
12- ENG D26316 Before Starting Break-in Pr ocedure Serious damage (for units with a tank) may result if the following break-in instructions ar e not closely followed. This procedur e is required befor e the air compressor is put into service and when the check valve or a complete compressor pump has been r eplaced.
13- ENG D26316 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● Drain T ank ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank ruptur e or an explosion.
14- ENG D26316 T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug unit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (turn counterclockwise) using a socket wr ench.
15- ENG D26316 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wrench r emove the gauges and hose from the regulator . 4. Remove the regulator .
16- ENG D26316 Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e.
17- ENG D26316 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur .
18- ENG D26316 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit br eaker with higher rating than that specified for your particular branch circuit.
19- ENG D26316 NOTES.
20- ENG D26316 AIR COMPRESSOR DIAGRAM 17 18 16 13 14 12 11 10 15 8 7 4 5 6 9 1 2 3 19.
21- ENG D26316 P ARTS LIST Key No Part Number Description 1 H-2099 Adapter 2 Z-GA-369 Pressur e Gauge 3 CAC-4296-1 Regulator 4 SS-1286 Nipple 5 SSP-6021 Bushing Reducer 6 D20114 Safety V alve 7 Z-DAC-.
22- ENG D26316 AIR COMPRESSOR PUMP DIAGRAM 1 15 20 14 16 13 12 7 4 10 11 9 8 6 5 3 21 2 18.
23- ENG D26316 P ARTS LIST Key No Part Number Description 1 AC-0471 Shroud, Left 2 AC-0470 Shroud, Right 3 CAC-1196 Cylinder Head 4 * CAC-1212 T ube Seal 5 * CAC-1199 Gasket Head 6 Z-D24985 V alve Pla.
24- ENG D26316 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all pr oducts covered under this warranty are free from defects in material and workmanship.
Een belangrijk punt na aankoop van elk apparaat Delta 66-202 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta 66-202 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta 66-202 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta 66-202 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta 66-202 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta 66-202 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta 66-202 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta 66-202 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.