DVPEN01-SL Ethernet Communication Module Application Manual.
.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 1 Warning 3 Please r ead this instruction car efully before use and follow th is instruction to operate the device in order to pr event damages on the device or injuries to staff. 3 Switch off the power befor e wiring.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 2 5.6 IP Filter ..................................................................................................................................... 23 5.7 S tatic ARP T able .......
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 3 1 Introduction Thank you for choosing DVPEN01-SL module. T o correctly inst all and operate DVPEN01-SL, please read the manual carefully before using the module. DVPEN01-SL is an Ethernet communication module for remote setting and communication through WPLSoft.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 4 Item S pecification Vibration/ Shock Resistance S tandard: IEC61 13 1-2, IEC 68 -2-6 (TEST Fc)/IEC61 131-2 & IEC 68-2-27 (TEST Ea) Electrical specifications Item S pecification Power supply voltage 24VDC (-15% ~ 20%) (Power is supplied by the internal bus of MPU.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 5 2.3 LED Indicators Indicator Color Indication POWER Green Power indication RS-232 Red Communication st atus of the series port 100M Orange Network connection st atus LINK Green Network communication speed 2.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 6 Connect DVPEN01-SL to the Network Connect DVPEN01-SL to t he Ethernet Hub by twisted pair cable CA T -5e. DVPEN01-SL has Auto MDI/MDIX function; therefore, DVPEN01-SL do es not need to use a crossing cabl e between the PC and DVPEN01-SL.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 7 CR# HW LW Attribute Content Explanation #7 R S tatus of E-Mail 1, 2 b0 ~ b7: Current status of E-Mail 2 b8 ~ b15: Current status o.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 8 CR# HW LW Attribute Content Explanation #1 19 R/W Modbus TCP data length Setting up the data length for Modbus TCP transactio n #2.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 9 CR value E-Mail status 10 Fail to connec t to SMTP-Server 1 1 Incorrect recipient E-Mail addre ss 12 SMTP-Server communication error 13 Exceeding the max.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 10 S toring the data to be transmitted to the remote MPU. CR#49 ~ 68: Data Receiving Buf fer Explanations: S toring the data received f r om the remote MPU.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 11 CR#70, 71: IP Address Explanations: 1. Setting up the IP address of our equipment in hex. When in DHCP mode, you can only read and cannot write. 2. Example: Assume you’d like to set the IP address as 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 12 CR#1 16: Modbus TCP S tatus Explanations: Displaying the current communication st atus of Modbus TCP mode .
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 13 registers (CR) in the extension module. Numbering of the modules: Every extension modul e conne cted to PLC MPU has a No. to allow you to know which module is which when compili ng the PLC program.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 14 2. Auto-search • Press “Auto-Search” (circl ed) to search for every DVPEN01-SL in the network and display them in the left column. • Move the cursor to the module you would like to set up.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 15 3. Searching by IP address • Set the transmission type as “Ethernet” first. Next c lick on the “Stat ic IP Search” icon (circled) to search for the designated IP. • Press the “search” icon and you will open the wind ow for entering the IP addres s.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 16 4. Opening DVPEN01 - SL setup page by RS-232` • Select “RS232" as the transmission type in co mmunication setting. You will have to designate a communication port. When DVPEN01-S L is searc hed by RS-232, you do not need to set up the parameters (i.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 17 • Module Name: There can be many DVPEN 01-SL modules in the network. Thus , you can set up a module name for each module to identify the module when you need to use them.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 18 sections), bordered by meridian s each 15° of longitude apart. The local time in n eighboring zones is then exactly one hour dif ferent.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 19 • Enter 192.168.0.1 into IP address. Click on “OK” to complete the IP address setting of the PC. 2. Setting up DVPEN01-S L Network • IP configuration: There are two types of IP, static IP and DHCP.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 20 IP Explanation Static The user e nters the IP address, subnet mask and gateway . DHCP DHCP server offers the IP address, subnet mask and gateway. • IP address: IP address is the location of the equipment in the network.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 21 1. SMTP Server: The E-Mail will first be sent to SMTP server , and SMTP server will send it to the designated address. For example, assume there is an E-Mail to be sent to test@delt a.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 22 5. Select recipient s: After you have set up all the parameters for the E-Mail, you will need to select recipients. The E-Mail will be sent to the designated recipients w hen the E-Mail is triggered.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 23 1. Enable Data Exchange: Check the box to enable or disable dat a exchange. S tart data exch ange after enable it. 2. Communi cation Address & Data exchange host IP: Y ou have to enter the IP address of DVPEN01-SL at the other end.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 24 1. Enable IP Filter Function: Check the box to enable IP filter . 2. IP: IP addresses that are allowed to establish connections. Maximum 8 IPs are allowed. 3. Netmask: The subnet of the IP is allowed to establish a connection.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 25 1. IP: Destination IP address in data transmission. 2. MAC: The MAC address corre sponding to the IP address. Note: Incorrect settings may result in connection failu re. The refore, DO NOT set the MAC address of the equipment without the network into the t able.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 26 1. Modify: Check the box to modify the passwo rd. 2. New Password: Maximum 4 characters are allowed. Lea ve the column “blank” to disable the p assword protection function. 3. Confirm Password: Enter the new password a gain.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 27 Check “Default Setting” box and click on “Y es”. Note: If you set up DVPEN01-SL by RS-2 32, you can return the setting to default setting whether the password is l o cked or not.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 28 1. Export: Save all the settings of DVPEN01-SL into *.eni files. The exported files do not incl ude the pass word . 2. Import: Select a file and the file will be imported to all the settings.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 29 Input IP Address: Press “Add” to record the IP address of the module into the list. 6 Application Examples 6.1 Setting up IP and Communicating through WPLSoft Application Setting up network parame ters of DVPEN01-SL directly on the PC.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 30 4. Click on “Auto-Search” icon to search for all DVPEN01-SL modules in the network.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 31 6. Open “Basic” setup page. 7. Switch to “Network” setup page.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 32 8. Enter IP address: 192.168.0.4; Netmask: 255.255.255.0; Gateway: 192.168.0.1. Press “OK” to complete the setup, and WPLSoft will automatically search for DVPEN01-SL. 9. The IP of DVPEN01-SL ha s been modified into the new setting (DELTA DVPEN01-SL: 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 33 PC Hu b DH CP Serve r PC DV P-PLC DV PEN 0 1 2. Open “Communication Setting” in WPLSoft.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 34 4. Click on “Auto-Search” icon to search for a ll DVPEN01-SL modules in the network. Follow “View Æ Workspace Æ Communication” or “View Æ Workspace Æ Projec t” to find the detected DVPEN01-SL module (default module name: DELT A DVPEN01-SL, IP: 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 35 6. Open the setup page. You can modify the module na me for easier identification. 7. Next, set up the new IP of DVPEN01-SL. First sw itch to “Network” setup page. If there is a DHCP server in the LAN, select DHCP in “IP Configuration”.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 36 6.3 Setting up IP and Communicating through WPLSoft Application Setting up network parame ters of DVPEN01-SL by ladder diag ram Network requirement (1) IP of DVPEN01-SL: 192.168.0.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 37 • Use T O instruction to write the network se tting parameters D0 ~ D7 into CR#69 ~ #75 in DVPEN01-SL. DVPEN01-SL is the first extension module numbered K100 attached at the left hand side of PLC.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 38 4. Open the setup page again, and DVPEN01-SL is now lo cked by the passwo rd. You cannot open any of the settings now. Click on “Unlock” to leave the entering password window. 5.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 39 6. To clear the password, simply leave the passw ord columns bl ank. Click on “OK” to clear the password.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 40 2. Check the “Default Setting” box an d the “Warning” dialog box will appear. Click on “Yes” to ret urn to default setting (in approx. 5 ~ 10 seconds), and the password will be cleared as well.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 41 3. Check “Enable IP Filter Function” box. Enter “1 92.16 8.0.7” in No. 1 IP and “255.255.255.255” in all “Netmask” columns. 4. Enter “192.168.0.1” in No. 2 IP and “255.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 42 6.7 Setting up S tatic ARP T able Application Setting up sta tic ARP table Network requirement (1) MAC address of equipment 192.168.1.6 is 00:18:23:10:00:35 (2) MAC address of equipment 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 43 Note: The MAC address of D VPEN01-SL can be obtained from WPLS oft or the MAC address sti cker on the equipment. The MAC address of PC can b e found in the “Network Conn ection Details” (see below).
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 44 3. In “Subject and Mail” page, enter the ad dress of SMTP server, subject of E-Mail, and E-mail address of the recipient. 4. Switch to “Select Recipients” page. Ch eck all the boxes of “Recipient 1”.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 45 5. After all the settings in DVPEN01-SL are comp leted, compile the ladder diag ram in the MPU and download it to the MPU.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 46 3. Check “Enable Data Exchange” b ox. Enter IP address of PLC_A “192.168.0.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 47 • Write the dat a in RTC into CR#29 ~ CR#35. • Write “1” into CR#13 to st art the data exchange. • CR#14 = 2 refers to successful excha nge. CR#14 = 3 refers to failed exchange.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 48 Explanations: • The data exchange will be executed every one second. • Write “0” into CR#28, and PLC_B will u s e CR# 25 ~ CR#26 as the IP address of the destination PLC. • Write the IP address of PLC_A into CR#25 and CR#26.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 49 END SET M2 M1 RS T K100 K1 M2 K14 D1 4 RS T M2 RS T M2 = D 1 4 K 2 = D 1 4 K 3 FRO M K100 K1 TOP K100 TO P K1 K 1 K0 K1 4 K13 K100 TO P K1 K86 H106 4 Explanations: • The data exchange will be executed every one second.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 50 M1013 K100 K1 K100 K100 K1 M2 M1 M1 SET M1 TOP TOP TOP K100 TOP K1 K100 K1 TOP K100 TOP K1 K1 K0 H4 HC0A 8 K1 H0 K100 K100 K1 TOP.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 51 • Write the length of the instrcutio n into CR#1 19. • Write “1” into CR#1 15 to start the ex ecution of Modbu s TCP instrcution. • CR#1 16 = 2 refers to successf ul execution.
Ethernet Communication Module DVPEN01-SL DVP-PLC Application Manual 52 MEMO.
Een belangrijk punt na aankoop van elk apparaat Delta Electronics Ethernet Communication Module DVPEN01-SL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta Electronics Ethernet Communication Module DVPEN01-SL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta Electronics Ethernet Communication Module DVPEN01-SL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta Electronics Ethernet Communication Module DVPEN01-SL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta Electronics Ethernet Communication Module DVPEN01-SL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta Electronics Ethernet Communication Module DVPEN01-SL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta Electronics Ethernet Communication Module DVPEN01-SL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta Electronics Ethernet Communication Module DVPEN01-SL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.