Gebruiksaanwijzing /service van het product Series L36SA van de fabrikant Delta Electronics
Ga naar pagina of 13
FEATURES High Efficiency: 88% @ 3.3V/15A Size: 49.6mm x 39.4mm x 8.9mm (1.95”x1.55”x0.35”) Industry standard pin out Fixed frequency operation Input UVLO, OTP , Output OCP , .
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V ou t unless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS L36SA3R315 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES 60 70 80 90 123456789 1 0 1 1 1 2 1 3 1 4 1 5 OUTPUT CURRENT (A) EFFICIENCY (%) 1 2 3 4 5 6 7 8 9 123456 7 89 1 0 1 1 1 2 1 3 1 4 1 5 OUTPUT CUR RENT (A) LOSS (W) Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs.
ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient a t full rated load current (resistive load) (5 ms/div). V in=48V .T op T race: V out, 1V/div; Bottom T race: ON/OFF input, 5V/div Figure 5: T urn-on trans ient at zero load current (5 ms/ div).
ELECTRICAL CHARACTERISTICS CUR VES 0 Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum capacitor and 1µF ceramic capacitor . T op T race: V out (1 00mV/div , 200us/div), Bottom T race: I out (3.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1 1: Input T erminal Ripple Current, i c , at full rated output current and nominal i nput voltage w ith 12µH source impedance and 33µF electrolytic capacitor (500 mA/div , 2us/div).
ELECTRICAL CHARACTERISTICS CUR VES output current range 0 0.5 1 1.5 2 2.5 3 3.5 0 5 10 15 20 Output current (A) Output voltage (V) Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=10A)(10 mV/div , 2us/div) Load capacitance: 1µF ceramic capacitor and 10µF t antalum capacitor .
The input source must be insul ated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
THERMAL CONSIDERA TI ONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer.
MECHANICAL DRA WING OPEN FRAME VERSION PIN NO. NAME FUNCTION 1 CASE (OPTION) CASE 2 +VIN POSITIVE INPUT VOL T AGE 3 –VIN NEGA TIVE INPUT VOL T AGE 4 NC NOT CONNECTED 5 ON/OFF REMOTE ON/OFF 6 TRIM OU.
DS_L36SA3R315_02142 007 13 P ART NUMBERING SYSTEM L 36 S A 3R3 15 N R F A T ype of Product Inpu t V olt age Number of Output s Product Series Output V olt age Output Current ON/OFF Logic Pin Length Option Code L- 2 x 1.6 Brick 18~75V S- Single Advanced 3R3-3.
Een belangrijk punt na aankoop van elk apparaat Delta Electronics Series L36SA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta Electronics Series L36SA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta Electronics Series L36SA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta Electronics Series L36SA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta Electronics Series L36SA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta Electronics Series L36SA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta Electronics Series L36SA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta Electronics Series L36SA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.