INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .
2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment.
4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times .
8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.
INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air .
10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current.
11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps.
12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence.
13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion.
15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench.
16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator .
17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e.
18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur .
19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit.
20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
Een belangrijk punt na aankoop van elk apparaat Delta OIL-FREE AIR COMPRESSOR CP503 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta OIL-FREE AIR COMPRESSOR CP503 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta OIL-FREE AIR COMPRESSOR CP503 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta OIL-FREE AIR COMPRESSOR CP503 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta OIL-FREE AIR COMPRESSOR CP503 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta OIL-FREE AIR COMPRESSOR CP503 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta OIL-FREE AIR COMPRESSOR CP503 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta OIL-FREE AIR COMPRESSOR CP503 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.