Gebruiksaanwijzing /service van het product AB20001 van de fabrikant Demco
Ga naar pagina of 16
OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL ASSEMBLY CALIBRATION OPERATION REPLACEMENT PARTS READ complete manual CAREFULLY BEFORE attempting operation.
Thank you for purchasing a Demco boom. We feel you have made a wise choice and hope you are completely satisfied with your new flotation boom. Your new Demco boom features the newest and most up-to-date design of a boom it's type currently marketed.
Normal sprayer frame, without Height Adjuster. (Shown Above) 1. Mount the Boom Carrier Center Section (#1) to the Mounting Angles (#2) on the back of the sprayer frame using four 3/8" x 2-1/2" square U-bolts (#3) and eight 3/8" nylon locknuts (#4).
MOUNTING THE BOOM CENTER SECTION TO HYDRAULIC HEIGHT ADJUST 7 4 3 15 15 14 28 16 15 5 4 8 2 2 6 2 2 6 5 11 12 5 3 3 3 5 5 3 2 16 15 16 15 17 14 5 3 5 3 1 25 24 23 22 21 20 20 19 13 26 26 13 2 18 18 27 15 16 29 2 18 11 5 5 2 16 16 3 5 17 3 5 17 3 5 R E F .
MOUNTING THE BOOM CENTER SECTION TO MANUAL HEIGHT ADJUST 2 2 3 5 5 5 5 5 3 3 3 6 7 9 11 13 15 16 16 17 17 18 2 19 24 24 29 30 5 4 9 23 9 2 23 27 26 25 1 3 5 3 3 5 16 14 12 10 6 2 19 16 17 17 19 7 3 2 17 16 5 5 31 9 25 26 27 2 20 5 22 3 2 4 5 3 18 17 16 15 3 5 18 8 28 5 5 29 24 (DFBHA OPTION) 8 21 27 25 26 R E F .
CENTER SECTION BOOM CARRIER BREAKDOWN 5 15 19 21 16 16 17 14 10 12 8 6 10 5 5 2 20 19 22 21 13 9 23 20 30 Note: This bracket must be 5" off center in either direction. ASSEMBL Y INSTRUCTIONS 1. Begin by referring to the boom carrier (#1) mounting to the sprayer frame (page 1) or mounting to the height adjust (pages 2 & 3).
LEFT INNER WING P ARTS BREAKDOWN 1. Attach the upper offset linkage (#6) to center section (#1) using one 1/2" x 2" bolt (#7), bushing (#8) and one 1/2" locknut (#9). 2. Next attach the lower linkage bracket (#10) to the upper offset linkage (#6) using one 1/2" x 2" bolts (#7) and one 1/2" locknut (#9).
RIGHT INNER WING P ARTS BREAKDOWN ASSEMBL Y INSTRUCTIONS 1. Attach the upper offset linkage (#6) to center section (#1) using one 1/2" x 1-3/4" bolt (#7), bushing (#8) and one 1/2" locknut (#9).
R E F . PART N O. NO. QTY. DESCRIPTION RIGHT AND LEFT OUTER WING P ARTS BREAKDOWN Page 7 Please order replacement parts by PART NO. and DESCRIPTION. 1. 03322 1 Left Inner Wing 2. 03323 1 Right Inner Wing 3. 03328 2 Right and Left Outer Wing 4. 03326 2 Breakaway Pin 5.
TIP PLACEMENT 1. Marking location of boom clamps: Mark the clamp locations by starting at the center of the center boom section. From this mark, locate 20 inch spaces to both ends of the boom. 2. Fasten preassembled boom lines: Fasten the boom clamps (#3) on the boom so the sprayer tip will be on the back side of the boom.
ADJUSTMENT PROCEDURES After the boom is completely assembled and before attempting to fold the boom for the first time, the boom should be adjusted so it lays straight both horizontally and vertically. There are several ad- justment points built into the boom for this purpose.
ADJUSTMENTS FOR FOLDING AND STORAGE 4. Finally unlock the latch between the center section and inner right wing. (4th fold) Fold the inner right wing and outer right wing back and around to fold to the rear of the center section and into the storage bracket and lock in place with pin.
RIGHT WING MAINTENANCE AND LUBRICA TION LEFT WING TWO GREASE ZERKS FIVE GREASE ZERKS Y our Flotation Boom is designed to require only occasional light maintenance. Atten- tion to the following procedures will signifi- cantly prolong the useful life of your boom.
7 2 1 3. 05619 2 Pin (1/2" x 3" lg.) 4. 02384 4 Machine Washer (1/2" ID x 14 GA.) 5. 00185 2 5/32" x 1 Cotter Pin 6. 05564 2 Wheel Fork 7. 05328 2 1/2" x 3" lg. Ball Lock Hitch Pin 8. 05566 2 Wing Mounting Plate 9. 02802 12 5/16"-18UNC Nylon Insert Locknut 10.
XR8001VS X 20 .07 5.3 4.3 2.8 2.2 25 .08 5.9 4.7 3.1 2.4 30 .09 6.4 5.1 3.4 2.6 40 .10 7.4 6.0 4.0 3.0 XR80015VS X 20 .11 7.8 6.3 4.3 3.2 25 .12 8.8 7.1 4.7 3.6 30 .13 9.7 7.7 5.2 3.9 40 .15 11.1 8.9 6.0 4.5 XR8002VS X 20 .14 10.5 8.4 5.6 4.2 25 .16 11.
SAFETY FIRST SPRA YER CHECK LIST Down time in the field caused by breakdowns is costly and time consuming. Many breakdowns can be eliminated by periodic equipment maintenance. By spending time run- ning over this checklist before seasonal spraying application time and following proper af- ter season care, you can save time and money later on.
Een belangrijk punt na aankoop van elk apparaat Demco AB20001 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Demco AB20001 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Demco AB20001 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Demco AB20001 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Demco AB20001 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Demco AB20001 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Demco AB20001 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Demco AB20001 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.