Gebruiksaanwijzing /service van het product (V)KC42P SERIES van de fabrikant Desa
Ga naar pagina of 40
FOR YOUR SAFETY WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions.
www .desatec h.com 1 16239-01B 2 SAFETY INFORMA TION WAR NI NG : Thi s pr odu ct co nt ain s an d/ or ge ne ra tes ch em ic als kn own to the Sta te of Cal if or nia to c au se ca nc er or b ir th de fe ct s or o th er r epr od uc tiv e ha rm .
3 3 www .desatec h.com 1 16239-01B SAFETY INFORMA TION Continued PR ODUCT IDENTIFICA TION Figure 1 - Direct-V ent Fireplace with Millivolt Ignition L OCAL CODES Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.
www .desatec h.com 1 16239-01B 4 PR ODUCT FEA TURES These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outsid e/exter ior wall (horiz ontal).
5 5 www .desatec h.com 1 16239-01B A B E F G H D C Nailing T abs 8 CLEARANCES Mi ni mu m cle ar an ces t o co mb ust ib le s for t he fi re pla ce a re as f ol lo ws: *Back and sides 0"/mm Perpe.
www .desatec h.com 1 16239-01B 6 Fixed Closed O pe n a bl e Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.
7 7 www .desatec h.com 1 16239-01B These models are tested and approved for use with DESA (direct- vent) pipe components and terminations. The vent ing syst em must term inate on the outsi de of the stru cture and can not be atta ched to a chimn ey or flue sys tem servi ng a sep arat e sol id fuel or gas burni ng appli ance .
www .desatec h.com 1 16239-01B 8 INST ALLA TION PLANNING There ar e two basic types of direct-vent installation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMP ORTAN T : Horizontal square terminations require only in- ner portion of wall firestop.
9 9 www .desatec h.com 1 16239-01B W ARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1 / 2 " round hole and attach to the exterior wall with four wood screws provided.
www .desatec h.com 1 16239-01B 10 Horizontal High Wind Square T ermination W all Firestop 45° Elbow Fig ure 14 - Hori zonta l Ter minat ion Co nfigur ation for Square or Round T erminations 45° Elb.
1 1 1 1 www .desatec h.com 1 16239-01B Figure 15 - Horizontal T ermination Configuration for Corner Installation Using One 90° Elbow Square T ermination W all Firestop Not to Exceed (H) Limits As Re.
www .desatec h.com 1 16239-01B 12 V enting with T wo 90° Elbows V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max.
13 13 www .desatec h.com 1 16239-01B INS TAL LATI ON F OR V ERTI CAL TER MINA TION Not e : V ertical restrictor must be installed in all vertical installa- tions.
www .desatec h.com 1 16239-01B 14 VENTING INST ALLA TION INSTR UCTIONS Continued V ertical T ermination Configurations Figures 21 through 24 show four different configurations for verti- cal termination. V enting with T wo 90° Elbows V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min.
15 15 www .desatec h.com 1 16239-01B VENTING INST ALLA TION INSTR UCTIONS Continued V ertical V enting V = 40' max. Figure 24 - V ertical V enting Configuration With No Horizontal Run (V ertical Round High Wind T ermination Shown) Note : Install restrictor into inner collar of fireplace as shown.
www .desatec h.com 1 16239-01B 16 CHECK GAS TYPE Us e pro pe r gas ty pe fo r th e fire pl ac e uni t you ar e ins ta ll ing . If you ha ve co nfl ic tin g gas ty pe s, do not in sta ll fire pl ac e.
17 17 www .desatec h.com 1 16239-01B Figure 26 - Attaching Speed Control to Firebox Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug-In FIREPLACE INST ALLA TION Installing Optional Blower Accessories (Cont.) Duplex Outlet (Located underneath firebox floor against lower right outside wall) 5.
www .desatec h.com 1 16239-01B 18 Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models Blower Wiring Diagram CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation.
19 19 www .desatec h.com 1 16239-01B FIREPLA CE INST ALLA TION Continued FIREPLACE INST ALLA TION Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace to Gas Supply Checking Gas Connections CA UTION : Us e o nly new, bla ck i ron or s teel pip e.
www .desatec h.com 1 16239-01B 20 Figure 33 - Equipment Shutoff V alve Open Closed Equipment Shutoff V alve Figure 35 - Checking Gas Joints for Natural Gas Fireplace Figure 34 - Checking Gas Joints fo.
21 21 www .desatec h.com 1 16239-01B FIREPLA CE INST ALLA TION Continued FIREPLACE INST ALLA TION Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door INST ALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES NOTICE: Use only alkaline batteries (not included).
www .desatec h.com 1 16239-01B 22 Lock Unlock Glass Frame Assembly Screw Fi gu re 42 - Removing/Replacing Glass Door Hinge Removing Glass Door If replacement of glass is necessary , the entire assembly , glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.
23 23 www .desatec h.com 1 16239-01B FIREPLA CE INST ALLA TION Continued FIREPLACE INST ALLA TION Installing Optional Brick Liner Models BL42DA(SA) and BL42DHA(SA) OPERA TING FIREPLACE For Y our Safet.
www .desatec h.com 1 16239-01B 24 O F F P I L O T L O I H O N Figure 45 - Control V alve Piezo Ignitor Gas Control Knob V ariable Control Knob OPERA TING FIREPLACE Lighting Instructions (Cont.
25 25 www .desatec h.com 1 16239-01B OPERA TING FIREPLACE Optional Hand-Held Remote Operation (Cont.) OPERA TING FIREPLACE Continued ON/OFF SERIES MODEL GHRCB Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 47).
www .desatec h.com 1 16239-01B 26 OPERA TING OPTIONAL BLOWER ACCESSOR Y Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel.
27 27 www .desatec h.com 1 16239-01B CLEANING AND MAINTENANCE Glass Door Pilot and Burners Logs V enting System C L E A N I N G A N D M A I N T E N A N C E W ARNING: T urn off fireplace and let cool before cleaning.
www .desatec h.com 1 16239-01B 28 TR OUBLESHOOTING Note: All troubleshooting items are listed in order of operation. W ARNING: T urn off heater and let cool before servicing. Only a qualified service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean pilot.
29 29 www .desatec h.com 1 16239-01B TROUBLESHOOTING OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during .
www .desatec h.com 1 16239-01B 30 TR OUBLESHOOTING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
31 31 www .desatec h.com 1 16239-01B Btu 27,000/38,000 Btu/hr 25,000/36,000 Btu/hr Gas T ype Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w .c. 10.0" w .c. Minimum Inlet 5.5" w .c. 11.0" w .c. Supply Pressure D im e ns i on ( H x W x D) Fireplace (Actual size of firebox.
www .desatec h.com 1 16239-01B 32 ILLUSTRA TED P ARTS BREAKDOWN Models KC42N, KC42P , VKC42N and VKC42P Series ILL USTRA TED P ARTS BREAKDOWN MODELS KC42N, KC42P , VKC42N AND VKC42P SERIES 6 7 20 17 1.
33 33 www .desatec h.com 1 16239-01B P ARTS LIST Models KC42N, KC42P , VKC42N and VKC42P Series P ARTS LIST MODELS KC42N, KC42P , VKC42N AND VKC42P SERIES This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.
www .desatec h.com 1 16239-01B 34 7 15 10 12 1 12 2 3 13 9 1 1 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5 ILL USTRA TED P ARTS BREAKDOWN BURNER ASSEMBL Y FOR MODELS KC42N, KC42P , VKC42N A.
35 35 www .desatec h.com 1 16239-01B P ARTS LIST BURNER ASSEMBL Y FOR MODELS KC42N, KC42P , VKC42N AND VKC42P SERIES This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.
www .desatec h.com 1 16239-01B 36 ACCESSORIES Purchase these fireplace accessories from your local retailer . If they can not supply these accessories, call DESA ʼ s Sales Department at 1-866-672-6040. for information. Y ou can also write to the address listed on the back page of this manual.
37 37 www .desatec h.com 1 16239-01B 1. Where will the product be used? � Living/Family Room � Office/W arehouse � Utility Shed/Outbuilding � Garage � Bedroom � Bathroom � Other 2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? � Y es � No 3.
www .desatec h.com 1 16239-01B 38 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE.
39 39 www .desatec h.com 1 16239-01B T APE NO TES ________________________________________________________________________________________________ _____________________________________________________.
LIMITED WARRANTY DIRECT -VENT FIREPLACE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Een belangrijk punt na aankoop van elk apparaat Desa (V)KC42P SERIES (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa (V)KC42P SERIES heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa (V)KC42P SERIES vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa (V)KC42P SERIES leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa (V)KC42P SERIES krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa (V)KC42P SERIES bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa (V)KC42P SERIES kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa (V)KC42P SERIES . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.