Ga naar pagina of 42
DIRECT -VENT FIREPLACE ® OWNER’S OPERA TION AND INST ALLA TION MANUAL BDV37N/P(A,B), DDV37N/P(A,B), BDV41N/P(A,B), AND DDV41N/P(A,B) Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.
2 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
3 105539 OWNER’S MANUAL PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149[.
4 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® Fireplace size D x FW x RW 37" 18 1 / 2 " 37" 14" 41" 18 1 / 2 " 41" 18" PRE-INST ALLA TION PREP ARA TION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard direct-vent fireplace.
5 105539 OWNER’S MANUAL C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 W all 29" 13" 10 1 / 4 " 8 3 / 4 " 37" 41" 37 1 / 2 " 41 1 / 2 " 58" 9 1 / 4 &.
6 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR .
7 105539 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life.
8 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.
9 105539 OWNER’S MANUAL UP UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 13 - Vent Opening Requirements Continued 3.
10 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® VENTING INST ALLA TION Continued UP UP Horizontal V enting V ertical (V) Horizontal (H) 37" min.
11 105539 OWNER’S MANUAL VENTING INST ALLA TION Continued UP V enting with T wo 90 ° Elbows V ertical (V) Horizontal (H 1 ) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min.
12 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 22).
13 105539 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 24 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 2.
14 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® V er tical V enting V = 40' max. Figure 29 - Vertical Rigid Venting Con- figuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 90 ° E lbo ws V ertical (V 1 ) Horizontal (H) 5' min.
15 105539 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet.
16 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® INSTALLING OPTIONAL BLOWER ACCESSORY IMPORTANT : For clarity, gas valve as- sembly and grate/burner assembly are not shown in Figures 31 through 34, page 17. They will, however, be in your fireplace when you are installing the blower.
17 105539 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued WARNING: Never touch the blower wheel while in operation. 10 . Peel of f the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (Figure 34).
18 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® Figure 36 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe.
19 105539 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator .
20 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1.
21 105539 OWNER’S MANUAL REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel. Do not operate this fire- place without the glass door panel securely in place. For replace- ment part information see Re- placement Parts , page 31.
22 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® INSTALLING OPTIONAL BRICK LINER D8037A/D8041 WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner. This brick liner kit is optional.
23 105539 OWNER’S MANUAL 1 2 3 4 6. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 49).
24 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® 1 2 3 WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. FIREPLACE INST ALLA TION Continued Figure 50 - Installing Log No.
25 105539 OWNER’S MANUAL O F F P I L O T O N L O I H OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
26 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® O F F P I L O T O N L O I H ON OFF REMOTE ON OFF INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height.
27 105539 OWNER’S MANUAL PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.
28 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
29 105539 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater pr.
30 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
31 105539 OWNER’S MANUAL SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP g.
32 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® SPECIFICA TIONS BDV/DDV37N(A,B) BDV/DDV37P(A,B) BDV/DDV41N(A,B) BDV/DDV41P(A,B) Btu 16,000/22,000 Btu/h 16,000/20,000 Btu/h 17,000/24,000 Btu/h 17,000/22,000 Btu/h Gas Type Natural Propane/LP Natural Propane/LP Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.
33 105539 OWNER’S MANUAL ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual.
34 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® 1 2 3 4 6 7 7 8 9 10 11 (Included in Hardware P ac k) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34-3 34-2 34-4.
35 105539 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE BDV37N(A,B) BDV41N(A,B) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY NO.
36 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® ILLUSTRA TED PA R T S BREAKDOWN BDV37P(A,B) BDV41P(A,B) 1 2 3 4 6 7 7 8 9 10 11 (Included in Hardware P ac k) 12 13 14 15 16 17 18 19 20 21 .
37 105539 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE BDV37P(A,B) BDV41P(A,B) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY NO.
38 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® ILLUSTRA TED PA R T S BREAKDOWN DDV37N(A,B) DDV41N(A,B) 1 2 3 4 5 5 5 6 6 5 6 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 1.
39 105539 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE DDV37N(A,B) DDV41N(A,B) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY NO.
40 105539 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) ® 1 2 3 4 5 5 5 6 6 5 6 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 33 34 35 .
41 105539 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE DDV37P(A,B) DDV41P(A,B) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY NO.
LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Een belangrijk punt na aankoop van elk apparaat Desa BDV41N/P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa BDV41N/P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa BDV41N/P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa BDV41N/P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa BDV41N/P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa BDV41N/P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa BDV41N/P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa BDV41N/P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.