Gebruiksaanwijzing /service van het product BLP155AT van de fabrikant Desa
Ga naar pagina of 20
PR OP ANE CONSTR UCTION HEA TER O WNER’S MANU AL ! GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC- TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
2 100585 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ..........................................
3 100585 2 SAFETY INFORMA TION Continued ! W ARNINGS Continued Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas may fade. Propane gas may be present even though no odor exists.
4 100585 PR ODUCT IDENTIFICA TION Figure 1 - 50,000 BTU/Hr Model Power Cord Hose /Regulator Assembly Inlet Connector Handle Shell Hot Air Outlet (Front) Fan Guard Piezo Ignitor Button Automatic Control Valve Button UNP A CKING 1. Remove all packing items applied to heater for shipment.
5 100585 Air For Combustion Air For Heating THEOR Y OF OPERA TION Combustion Chamber Clean Heated Air Out (Front) Hose/Regulator Assembly Cool Air In (Back) The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.
6 100585 INST ALLA TION Inlet Connector Hose Figure 4 - Hose and Inlet Connector ! W ARNING Review and understand the warnings in the Safety Informa- tion Section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
7 100585 4. Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly. 5. Check all connections for leaks.
8 100585 5. Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly. OPERA TION Continued ! W ARNING Be sure motor and fan are running before pushing in auto- matic control valve button.
9 100585 ST ORA GE 1. Store propane tank(s) in safe manner. See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and/or CAN/CGA B149.2. Follow all local codes. Always store propane tanks outdoors. 2. Place plastic cover caps over brass fittings on inlet connector and hose/regula- tor assembly.
10 100585 TROUBLE- SHOO TING Check voltage to electrical out- let. If voltage is good, check heater power cord for breaks. Adjust motor/fan guard to keep fan from hitting inside of heater shell. Bend fan guard if neces- sary. Replace fan. See Fan, page 12.
11 100585 SER VICE PR OCEDURES Motor 1. Access ground screw through underside of heater base. Remove ground screw. Disconnect the green motor wire and the green power cord wire from underside of shell (see Figure 6). 2. Remove black and white motor wires from terminal board (see Figure 6).
12 100585 10. Attach fan guard to new motor with three nuts. Tighten nuts firmly. 11. Place fan onto motor shaft of new motor. IMPORTANT: When placing fan onto motor shaft, make sure part number stamped on fan is facing motor. Attach fan nut to end of motor shaft.
13 100585 Ignitor 1. Remove motor and fan guard from heater (see Motor, page 11, steps 1 through 5). 2. Remove black ignitor wire from piezo ignitor. Access ignitor wire through underside of heater base (see Figure 11). Push wire up through bushing in heater shell.
14 100585 Black Black Green White Green Terminal Board White White Blue Blue T Thermal Switch 8 6 4 2 7 5 3 1 Relay Red Red Gas Valve Piezo Ignitor Electrode CONNECTION DIAGRAM Blue Rl White Red Red T.
15 100585 Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replace- ment part(s), either contact your nearest authorized service center or call DESA International’s Technical Service Department at 1-800-323-5190.
16 100585 ILLUSTRA TED PA R T S BREAKDO WN 1 2 3 2 4 6 7 8 9 38 11 21 22 41 23 24 17 35 36 19 20 21 5 10 27 16 12 13 14 15 FAN NUT FAN RUBBER WASHER MOTOR MOTOR ASSEMBLY 17 26 18 26 25 34 30 37 29 31 .
17 100585 P AR TS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.
18 100585 NO TES _______________________________________________________________ _______________________________________________________________ _______________________________________________________.
19 100585 NO TES _______________________________________________________________ _______________________________________________________________ _______________________________________________________.
W ARRANTY AND REP AIR SER VICE LIMITED WARRANTY KEEP THIS WARRANTY For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include model number and serial number.
Een belangrijk punt na aankoop van elk apparaat Desa BLP155AT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa BLP155AT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa BLP155AT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa BLP155AT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa BLP155AT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa BLP155AT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa BLP155AT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa BLP155AT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.