DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS MODEL DVFH34 PROP ANE/LP GAS MODEL DVFH34P Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building.
2 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
3 106394 OWNER’S MANUAL PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code, ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149[.
4 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P Fireplace size D x FW x RW 34" 18 1 / 2 " 34 3 / 8 " 14" PRE-INST ALLA TION PREP ARA TION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your FMI direct-vent fireplace.
5 106394 OWNER’S MANUAL 29" 13" 12 5 / 8 " 34 3 / 8 " 35 1 / 16 " 58" 9 1 / 4 " 41" Nailing T abs PRE-INST ALLA TION PREP ARA TION Continued Figure 6 - Framing Clearances for Corner Installation These models are approved for use with FMI 7" direct-vent pipe components and terminations.
6 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA T.
7 106394 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Fail- ure to do so could result in serious injury, property damage or loss of life. Operation of improperly in- stalled and maintained venting sys- tem could result in serious injury, property damage or loss of life.
8 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.
9 106394 OWNER’S MANUAL UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 12 - Vent Opening Requirements 3. Attach vent pipe assembly to the fire- place.
10 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P VENTING INST ALLA TION Continued UP UP Horizontal V enting V ertical (V) Horizontal (H) 37" min.
11 106394 OWNER’S MANUAL VENTING INST ALLA TION Continued UP V enting with T wo 90 ° Elbows V ertical (V) Horizontal (H 1 ) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min.
12 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 20).
13 106394 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 22 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 2.
14 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P V ertical V enting V = 40' max. Figure 27 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° E lbo ws V ertical (V 1 ) Horizontal (H) 5' min.
15 106394 OWNER’S MANUAL PARTS LISTS FOR VENTING KITS AND COMPONENTS FMI Rigid Venting Number Description FD30 30˚ Starter/Adapter (6 5/8" to 7") 6 per box FD60 60˚ Starter/Adaptor (6 5/.
16 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P INSTALLING OPTIONAL BLOWER ACCESSORY IMPORTANT : For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 29 through 32 , page 17. They will, however, be in your fireplace when you are installing the blower.
17 106394 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued WARNING: Never touch the blower wheel while in operation. 10 . Peel of f the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (Figure 32).
18 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P Figure 34 - Gas Connection * The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer. CAUTION: Use only new, black iron or steel pipe.
19 106394 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator .
20 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.
21 106394 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left. 2 . Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver .
22 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts , page 33.
23 106394 OWNER’S MANUAL INSTALLING OPTIONAL BRICK LINER D8037A WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner. This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, p ages 36 and 37.
24 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. FIREPLACE INST ALLA TION Continued NOTICE: Do not put lava rock on burner or under burner.
25 106394 OWNER’S MANUAL OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
26 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P O F F P I L O T O N L O I H ON OFF REMOTE ON OFF OPERA TING FIREPLACE Continued Blower Control Knob (Optional Accessory) Variabl.
27 106394 OWNER’S MANUAL Figure 60 - Typical Flame Pattern OPERATING OPTIONAL BLOWER ACCESSORY Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
28 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.
29 106394 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot.
30 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smo.
31 106394 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
32 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace wil.
33 106394 OWNER’S MANUAL SPECIFICA TIONS DVFH34 DVFH34P Btu 17,000/24,000 Btu/hr 17,000/22,000 Btu/hr Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.
34 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P ILLUSTRA TED PA R T S BREAKDOWN DVFH34 DVFH34P 1 2 3 4 6 6 39 5 5 6 5 1 1 (Included in Hardware Pack) 7 7 8 10 9 12 13 14 15 16 .
35 106394 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE DVFH34 DVFH34P This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY.
36 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P MANUAL BLOWER KIT GA3700 Manual-variable control blower accessory for the DVFH Series fireplaces. THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610TA Provides better heat distribution.
37 106394 OWNER’S MANUAL ACCESSORIES Continued AUTO ON OFF COOLER WARMER TEMP RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SERIES For all models. Allows the heater to be turned on and off conveniently.
38 106394 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/LP) DVFH34, DVFH34P NOTES _______________________________________________________________________________________________ __________________________.
39 106394 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Een belangrijk punt na aankoop van elk apparaat Desa DVFH34 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa DVFH34 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa DVFH34 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa DVFH34 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa DVFH34 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa DVFH34 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa DVFH34 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa DVFH34 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.