Save this manual for future reference. DIRECT -VENT GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL ® EVDDVF36PN (PENINSULA) AND EVDDVF36STN (SEE THRU) NA TURAL GAS - ELECTRONIC IGNITION This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.
2 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® FRONT VIEW 30 (76cm) (Opening) 23 5 / 8 (60cm) 25 (64cm) RIGHT SIDE 22 5 / 8 (57cm) 43 1 / 8 (110cm) 32 (81cm) (Opening) 1 7 / 8 (5cm).
3 106573 OWNER’S MANUAL Model EVDDVF36PN series is a three-sided direct-vent gas fireplace with a sealed com- bustion chamber. Model EVDDVF36STN series is a two-sided direct-vent gas fire- place with a sealed combustion chamber.
4 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® FRAMING Once the final location has been determined, observing height clearances for vent termi- nation, you may construct framing using dimensions shown in Figures 7 through 9, page 5, depending on your installation.
5 106573 OWNER’S MANUAL Figure 7 - Rough Opening for Installing Peninsula Fireplace 39 3 / 4 " (1010mm) Min. 40 1 / 2 " (1029mm) 23 5 / 8 " (600mm) 39 3 / 4 " (1010mm) Min.
6 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION C.
7 106573 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life.
8 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will tak e. Note: The location of the horizontal vent termination on the exterior w all must meet all local and national building codes and must not be easily blocked or obstructed.
9 106573 OWNER’S MANUAL UP UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1/2" (190mm) V ent Opening Combustible W all V ent Opening Non-Combustible W all Figure 17 - Vent Opening Requirements Continued 3.
10 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® VENTING INST ALLA TION Continued UP Figure 21 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow Figure 22 - Horizontal Termination Using Flexible Venting Horizontal V enting V ertical (V) Horizontal (H) 49.
11 106573 OWNER’S MANUAL VENTING INST ALLA TION Continued V enting with T wo 90° Elbo ws V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 4' max. 6' min. 8' max. 7' min. 10' max. 8' min. 15' max. 20' max.
12 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to a void obstructions, you must support the vent pipe e very 3 feet. Use wall straps for this purpose (see Figure 24).
13 106573 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 26 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 2.
14 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® V er tical V enting V = 40' max. Figure 31 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 90° El b ow s V ertical (V 1 ) Horizontal (H) 5' min.
15 106573 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet.
16 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® INST ALLA TION INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation.
17 106573 OWNER’S MANUAL INST ALLA TION Continued GAS LINE HOOK-UP Figure 39 - Typical Exterior Wall Gas Shutoff Installation WARNING: Gas line hookup should be done by your gas sup- plier or a qualified service person. WARNING: Before you pro- ceed, make sure your gas supply is OFF.
18 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® INST ALLA TION Continued WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints.
19 106573 OWNER’S MANUAL INST ALLA TION Continued WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.
20 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® OPERA TING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, the appliance may emit a slight odor for about 16 - 24 hours.
21 106573 OWNER’S MANUAL OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the main b urner .
22 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® TECHNICAL SER VICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
23 106573 OWNER’S MANUAL TROUBLESHOOTING OBSERVED PROBLEM Can not light main burner No gas to burner, although wall switch and valve are set to the ON position Frequent flame outage Burner goes off after a short time POSSIBLE CAUSE 1. No gas supply , or shutoff valv e is OFF 2.
24 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® OBSERVED PROBLEM Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise just after burners are lit or shut off REMEDY 1.
25 106573 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
26 106573 DIRECT -VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN ® ACCESSORIES LOG SET - 105891-01 (27237) Log Piece A - 105896-01 (27238) Log Piece B - 105895-01 (27239) Log Piece C - 105893-01 (2724.
27 106573 OWNER’S MANUAL END GLASS ASSEMBLY (Peninsula Only) 106922-01 (26624) (Tempered) REFRACTORY PIECES Front (Bottom) 105886-01 (25854) Left/Right (Bottom) 105887-01 (25856) Rear - 106924-01 (2.
LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Een belangrijk punt na aankoop van elk apparaat Desa EVDDVF36PN (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa EVDDVF36PN heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa EVDDVF36PN vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa EVDDVF36PN leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa EVDDVF36PN krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa EVDDVF36PN bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa EVDDVF36PN kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa EVDDVF36PN . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.