ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury.
2 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels.
3 106068 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage.
4 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No.
5 106068 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
6 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item How Often How To Fuel tank Flush every 150-200 hours See Storing, Transporting, or of operation or as needed Shipping Air output and Replace .
7 106068 OWNER’S MANUAL WARNING: Never service heater while it is plugged in, operat- ing, or hot. Severe burns and electrical shock can occur. TROUBLESHOOTING OBSERVED FAULT Heater ignites, but fla.
8 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard.
9 106068 OWNER’S MANUAL PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Operation , page 5). Allow motor to reach full speed. 4. Adjust pressure to 6.
10 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 9. Blow compressed air through face of nozzle. This will free any dirt in nozzle area. 10. Inspect nozzle seal for damage. 1 1. Replace nozzle into burner head and tighten firmly (80-1 10 inch-pounds).
11 106068 OWNER’S MANUAL PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-driver . 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-driver .
12 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN REM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10.
13 106068 OWNER’S MANUAL P ARTS LIST REM200T 200,000 Btu/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
14 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 WHEELS AND HANDLE PARTS LIST KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2204 Handles 2 2 M12345-33 Screw, #10-24 x 1 3 / 4 "8 3 M.
15 106068 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts.
W ARRANTY AND REP AIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship.
Een belangrijk punt na aankoop van elk apparaat Desa REM200T (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa REM200T heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa REM200T vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa REM200T leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa REM200T krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa REM200T bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa REM200T kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa REM200T . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.