Gebruiksaanwijzing /service van het product VM36P(B,H) van de fabrikant Desa
Ga naar pagina of 32
For more information, visit www .desatech.com NA TURAL GAS MODELS M36(B,H), M42(B ,H), VM36(B,H) AND VM42(B,H) PROP ANE/LP GAS MODELS M36P(B,H), M42P(B ,H), VM36P(B,H) AND VM42P(B ,H) B-VENT DECORA TI.
www .desatech.com 108795-01V 2 W ARNING: Improper installation, adjustment, al - teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in - stallation and operational procedures.
www .desatech.com 108795-01V 3 SAFETY 1. This appl ianc e is only for use with the typ e of gas indica ted on the rati ng pla te. This appl ian ce is n ot con ver tibl e for use wit h other gases unless a certied kit is used. 2. For propane/LP replace, do not place propane/LP supply tank(s) inside any structure.
www .desatech.com 108795-01V 4 1 1. K ee p t he a r ea a r ou n d yo u r fi r ep la c e clear of combustible materials, gasoline and other ammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around replace.
www .desatech.com 108795-01V 5 The insta llat ion must confo rm with local codes or , in the absence of local codes, with the cur - rent National Fuel Gas Code, ANSI Z223.
www .desatech.com 108795-01V 6 PRODUCT SPECIFICA TIONS GAS RA TING - NA TURAL M36(B,H),VM36(B,H) M42(B,H),VM42(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure: 4.
www .desatech.com 108795-01V 7 PRE-INST ALLA TION PREP ARA TION Figure 3 - Minimum Clearances (T op V iew) 0" 0" Clearance Nailing Flange Front Face Left Side Surround Back Drywall 2 x 4 Stud Figure 4 - Minimum Clearances (Front V iew) * * * * 42" (106.
www .desatech.com 108795-01V 8 PRE-INST ALLA TION PREP ARA TION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering.
www .desatech.com 108795-01V 9 INST ALLING TRANSITION PIPE AND ST ARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the replace, unattached and ready for installation. Re - move starter collar and set aside. Slide transition pipe over vent collar and attach with a minimum of three screws.
www .desatech.com 108795-01V 10 Maintain Listed Clearance Maintain Listed Clearance 12' Min. 12' Min. 45° 45° 6' 8' 12' Min.
www .desatech.com 108795-01V 11 CHECKING FOR PROPER VENTING After completing and checking electrical, gas and vent connections, follow the lighting instructions and allow main burner to run for approximately 5 minutes.
www .desatech.com 108795-01V 12 Conduit Sleeve T o Safety Circuit Route Millivolt Through Gas Line T o T hermopile Wires (Supplied) W a ll Switch (Not Supplied) (Back View) IN TH TP THTP IN OU T O F F P I L O T O N Note: If any of the original wire as supplied must be replaced, use 1 8 AWG TYP E CL 2 (U L) 105 C (25 ft.
www .desatech.com 108795-01V 13 GAS LINE HOOK-UP W ARNING: Gas line hookup should be done by your gas supplier or a qualied service person. W ARNING: Before you pro- cee d, make sur e your gas supp ly is OFF .
www .desatech.com 108795-01V 14 P I L O T ON OFF IN OUT Figure 21 - Connecting Flexible Gas Line to Millivolt V alve Gas Shutoff V alve Flexible Gas Line Do NOT Kink 1/2" NPT Incoming Gas Line No.
www .desatech.com 108795-01V 15 0.5" 0.5" Figure 24 - Pan and Ember Material Clearances Grate Burner Pan Pan and Ember Material INST ALLA TION Continued LOGPLACEMENTFORM36,M36P , VM36 AND VM36P MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 25.
www .desatech.com 108795-01V 16 INST ALLA TION Continued LOGPLACEMENTFORM42,M42P , VM42 AND VM42P MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 29). 2. Insert lower end of log 2A between rst two grate ngers and position upper end into notch on front of log 1.
www .desatech.com 108795-01V 17 INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left sid e of repla ce onl y . The vent can be inst all ed through any outside wall a minimum of three feet below fireplace termination cap.
www .desatech.com 108795-01V 18 6. Repeat the process for the opposite door assembly . 7. T o adjust doors, slide them partially open. Using a screwdriver , loosen hold-down screws in the spring clip (see Figure 36) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at outer edges of face.
www .desatech.com 108795-01V 19 OPERA TION 1. STOP! Read the safety information, col - umn 1. 2. T urn wall switch to the OFF position. 3. T urn off all electric power to appliance. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel.
www .desatech.com 108795-01V 20 TO TURN OFF GAS TO APPLIANCE 1. T urn off wall switch. 2. T urn off all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
www .desatech.com 108795-01V 21 INSPECTING B URNERS Continued BURNER FLAME P A TTERN Burner ames will be steady , not lifting or oat - ing. Flames should go up through the middle of logset. Flames should not "spill" to edges of pan or sides of logset.
www .desatech.com 108795-01V 22 DO NO T CONNECT RED REPLACE F A CTOR Y WIRING WITH 105°C EQUI V A LENT OR HIGHER RA TING THERMOST A T WIRE 18 GA. RED/WHITE EXTERNA L WIRING USE ON L Y CLASS 2 N.C.SW (VEN T SAFET Y SHUTOFF SWITCH) WHITE TH/TP TP TH WA LL SWITCH (NOT SUPPLIED) MANUA L DAMPER SWITCH N.
www .desatech.com 108795-01V 23 TROUBLESHOO TING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1.
www .desatech.com 108795-01V 24 TROUBLESHOO TING Continued OBSERVED PROBLEM Pilot goes out when wall switch is ON Spark ignitor will not light pilot after repeated triggering of red button Fireplace produces a clicking/ ticking noise just after burner is lit or shut off POSSIBLE CAUSE 1.
www .desatech.com 108795-01V 25 TROUBLESHOO TING Continued W ARNING:Ifyousmellgas • Shutoffgassupply . • Donottrytolightanyappliance. • Do not touch any electrical switch; do not use any phone in your building.
www .desatech.com 108795-01V 26 P ARTS MODELS M36(B,H),M36P(B,H),M42(B,H),M42P(B,H),VM36(B,H),VM36P(B,H), VM42(B,H) ANDVM42P(B,H) 43 21 1 10 1 1 6 8 8 22 25 13 4 14 45 17 3 44 .
www .desatech.com 108795-01V 27 P ARTS This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY NO. M36(B,H) VM36(B,H) M42(B,H) VM42(B,H) DESCRIPTION QTY 1 14153 14153 Micro Switch 1 2 111 6 5 111 6 5 Screw , #10 x 5/8 Mod.
www .desatech.com 108795-01V 28 KEY NO. M36(B,H) VM36(B,H) M42(B,H) VM42(B,H) DESCRIPTION QTY 12 106658-02 107812-02 Left Refractory , Std. Brick (M36B/M42B) 1 108164-02 108169-02 Left Refractory , Herringbone (M36H/M42H) 1 106658-01 107812-01 Left Refractory , Std.
www .desatech.com 108795-01V 29 P ARTS LOGSETS FOR MODELS M36(B,H),M36P(B,H),VM36(B,H) ANDVM36P(B,H) KEY NO. P ART NUMBER DESCRIPTION QTY .
www .desatech.com 108795-01V 30 KEY NO. P ART NUMBER DESCRIPTION QTY . - 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 1 1" 1 2B 108839-01 Right Front Log - 15 3 / 4 &quo.
www .desatech.com 108795-01V 31 ACCESSORIES NOTICE: Allaccessoriesmaynotbeavailableforallreplacemodels. Purc has e th ese access ori es f rom your local dealer . If th ey can not sup ply the se a cces sori es call DESA Heati ng, LLC at 1-866- 672- 604 0 for info rmat ion .
108795 01 108795-01 Rev . V 08/08 NOT A UPC DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www .desatech.com 1-866-672-6040 WARRANTY KEEP THIS WARRANTY Model ( located on product or identication tag ) _____________________________ Serial No.
Een belangrijk punt na aankoop van elk apparaat Desa VM36P(B,H) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa VM36P(B,H) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa VM36P(B,H) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa VM36P(B,H) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa VM36P(B,H) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa VM36P(B,H) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa VM36P(B,H) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa VM36P(B,H) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.