CE MOUNTING and OPERA TING MANUAL Reversible Air-to-W ater Heat Pump for Outdoor Installation LA 16ASR Order No.: 452158.66.21 FD 8 5 07.
2 1 READ IMMEDIA TEL Y 3 1.1 Important Information 1. 2 Legal Provisions and Guidelines 1. 3 Energy-Efficient Use of Heat Pumps 2 PURPOSE OF HEA T PUMP 4 2. 1 Application 2. 2 Principle of Operation 3 SCOPE OF DELIVER Y 4/5 3. 1 Baseline Unit 3. 2 Control Box 3.
3 READ IMMEDIA TEL Y 1.1 Important Information Prior to opening the unit it must be ensured that all electrical circuits are disconnected from the power source. During transport, the heat pump must not be tilted more than 45 ° (in either direction). Heat pump and transport pallet are only connected by the packaging film.
4 valve as well as the low-noise compressor , a desuperheater , a condenser and the electric control unit. In the case of low ambient temperatures, air humidity may accumulate on the evaporator in the form of frost impairing the heat transfer . The evaporator is automatically defrosted by the heat pump, if required.
5 2. 2. 1. 1. 1. 3. 1. 1. 3. 2. SCOPE OF DELIVER Y TRANSPORT 4 CAUTION! 3.2 Control Box The control box is integrated in the heat pump. It can be folded downward after removing the lower front panel and loosening the fastening screws located at the top on the right.
6 INST ALLA TION MOUNTING 6 INST ALLA TION 5.1 General The unit should always be installed on a permanently level, smooth and horizontal floor . The entire base frame surface should thereby make close contact with the floor in order to ensure adequate sound insulation and to prevent water-carrying parts from cooling out.
7 MOUNTING COMMISSIONING 6.3 Electrical Connection The power connection of the heat pump is effected via a commercially available 4-core cable. The cable has to be supplied by the client and the wire .
8 COMMISSIONING CLEANING / MAINTENANCE f ) Once all heating circuit are fully open and a heating water temperature of approx. 25 ° C is maintained in the buffer tank, the minimum flow rate must be set on the overflow valve and the heating circulating pump.
9 CLEANING / MAINTENANCE MALFUNCTIONS / TROUBLESHOOTING DECOMMISSIONING the supply and return line of the heat pump. The regulations of the trade associations must be adhered to.
10 APPENDIX 11.1 DIMENSION DRAWING 1 1 11.2 EQ UIPMENT D A T A 1 2 11.3 SCHEMA TICS 1 1.3.1 Heating Mode 1 3 1 1.3.2 Cooling Mode 1 4 11.4 WIRING DIAGRAMS 1 1.4.1 C ontrol 15 1 1.4.2 Load 16 1 1.4.3 T erminal Diagram 1 7 1 1.4.4 Legend 18 11.5 HYDRA ULIC BL OCK DIAGRAM 1 9 11.
11 Dimension Drawing APPENDIX: 11.1 DIMENSION DRAWING.
12 Equipment Data APPENDIX: 11.2 EQUIPMENT D A T A.
13 1 1.3.1 Heating Mode APPENDIX: 11.3 SCHEMA TICS.
14 1 1.3.2 Cooling Mode APPENDIX: 11.3 SCHEMA TICS.
15 1 1.4.1 Control APPENDIX: 11.4 WIRING DIAGRAMS Cable diameters all 0,75mm 2 Control lead 20x1,0mm 2 Heat pump controller.
16 1 1.4.2 Load APPENDIX: 11.4 WIRING DIAGRAMS PE distributor Mains Cable diameters all 0,75mm 2 ye/gn ye/gn.
17 1 1.4.3 T erminal Diagram APPENDIX: 11.4 WIRING DIAGRAMS T erminal connection diagram and connector assignment in the reversible air-to-water outdoor unit ye/gn Mains Control lead Connecting lead L.
18 E1 Crankcase heater , compressor E2 Fan for nozzle ring heater E3 Defrost end pressostat E4 Condensing pressure pressostat F2 High-pressure pressostat F3 Low-pressure pressostat F5 Thermostat HG F2.
19 Hydraulic Block Diagram APPENDIX: 11.5 HYDRA ULIC BL OCK DIAGRAM N1-N05 (HUP) N1-N06 (WUP) N2-N02 (SUP) N1-N010 EV N1-B3 (WWF) KW T WW EV N2-N01 (HUPR) N1-B6 (NKF) N1-N04 (2.
20 EC Declaration of Conformity APPENDIX: 11.6 EC DECLARA TION OF CONFORMITY Declaration of Conformity The undersigned KKW Kulmbacher Klimageräte-W erk GmbH, Geschäftsbereich Dimplex Am Goldenen Fel.
Notes 21.
Notes 22.
Notes 23.
KKW Kulmbacher Klimageräte-Werk GmbH T echnical data subject to change without notice Geschäftsbereich Dimplex Fax +49 (0) 92 21 709-589 Am Goldenen Feld 18 www .
Een belangrijk punt na aankoop van elk apparaat Dimplex LA16ASR (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dimplex LA16ASR heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dimplex LA16ASR vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dimplex LA16ASR leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dimplex LA16ASR krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dimplex LA16ASR bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dimplex LA16ASR kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dimplex LA16ASR . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.