Gebruiksaanwijzing /service van het product 6500 van de fabrikant DKS
Ga naar pagina of 48
Series 6500 Owner’ s Manual Series 6500 Vehicular Swing Gate Operator Copyright 2008 DoorKing, Inc. All rights reserved..
.
Class of Operation Model 6500 - UL325 Class I, II, III, IV T ype of Gate Vehicular Swing Gates Only Horsepower 1/2 or 1 HP Voltage / Phase 115 V AC Single-Phase, 230 V AC Single-Phase, 460 V AC Single-Phase Current ½ HP – 5.4 Amps @ 120V; 2.7 Amps @ 230V ; 1.
2 6500-065-K-7-08 SPECIFICA TIONS 1 SECTION 1 - INST ALL A TION 10 SECTION 2 - WIRING 14 Gate Construction Impor tant Safet y Instructions Instructions regarding intended installation: Impor tant Noti.
3 6500-065-K-7-08 SECTION 3 - ADJUSTMENTS 22 SECTION 4 - OPERA TING INSTRUCTIONS 25 SECTION 6 - MAINTENANCE AND TROUBLESHOOTING 31 21 21 2.8 Auxiliary T erminal Description 2.9 Secondary Operator T erminal Description 3.1 Circuit Board Adjustments 3.2 DIP-Switch Settings 3.
4 6500-065-K-7-08 Gate Construction Instructions regarding intended installation: Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.
5 5 6500-065-K-7-08 • For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
6 6500-065-K-7-08 6 UL325 Entrapment Protection Class I Class I and II Class III Class IV Class II Class III Class IV A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
7 7 6500-065-K-7-08 Glossar y GA TE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier , that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
8 6500-065-K-7-08 Swing Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage.
9 9 6500-065-K-7-08 Swing Gate Protection Non-contact Sensor Reverse Loop Shadow Loop Automatic Exit Loop C D D C Minimizes the potential of the gate closing when a vehicle is present. Number and placement of loops is dependent on the application. Reverse Loop Minimizes the potential of the gate closing when a vehicle is present.
10 6500-065-K-7-08 SECTION 1 - INST ALL A TION Prior to beginning the installation of the swing gate operator , we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner .
11 6500-065-K-7-08 Space Gained from Standard Compact Installation 22” 28” 22” 28” Standard Installation Operator Installation 1.3 T ype of Installations Recommended for all gate lengths opening 90°.
22” 28” 22” 28” Concrete Pad Location Operator Installation 42” 23” 2” 90° Plus Installation requires the Standard Compact Installation’ s concrete pad to be moved 2” away from the gate’ s open position. This distance of the gate’ s arm will var y depending on how far the gate will open.
13 6500-065-K-7-08 Gate Bracket Crank Arm Control Arm Release hub with release tool. DO NOT REMOVE HUB! Bolt crank arm to operator . Slide elbow assembly on crank arm. Bolt control arm to gate bracket. Slide control arm into elbow assembly . KEEP ARM ASSEMBL Y LEVEL .
14 6500-065-K-7-08 1.6 Determining Arm Lengths Slide elbow assembly back and fourth, manually opening and closing gate until satisfied with the gate’ s 90° open and fully closed positions. Mark and cut off excess arms. Secure arms to elbow assembly with 6 allen screws.
15 Chassis Ground Electrical Box Knock-outs Conduit Neutral 115 V AC 115 VAC Models Electrical Box Knock-outs Conduit 230/460 V AC 230/460 V AC 115 V AC Neu 115 V AC Neu 115 V AC Hot 2.1 High Voltage Wire Runs 2.2 High Voltage T erminal Connections The distance shown in the chart is measured in Feet from the operator to the power source.
16 6500-065-K-7-08 2.3 Control Wiring Radio Receiver power only . Power is limited to 250 ma. Open direction non-contact sensor . Stops the gate in the open cycle only . Gate resumes normal operation when the obstruction is cleared. Close direction non-contact sensor .
17 Automatic exit loop lead in wires are twisted approx. 6 twists per foot. Reverse loop lead in wires are twisted approx. 6 twists per foot and are wired in series. Shadow loop lead in wires are twisted approx. 6 twists per foot. 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Reverse Reverse Automatic Exit Shadow 2.
18 6500-065-K-7-08 2.5 Auxiliar y Device Wiring 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 The Remote Alarm Reset Station (Model 1404-080) MUST be mounted in the line-of-sight of the gate operator . T erminal 5 required only if the tracker board will activate the gate operator .
19 19 2.6 Primar y / Secondar y (Dual) Gate Connection 1 Motor 2 Motor 3 Neutral 4 24VAC 5 Limit 6 Spare 7 Limit 8 COM 1 Motor 2 Motor 3 Neutral 4 24VAC 5 Limit 6 Spare 7 Limit 8 COM Conduit Primary/secondar y interconnection cable in underground conduit.
20 6500-065-K-7-08 2.7 Main T erminal Description 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1. LOW VOL T AGE COMMON 2. RADIO RELA Y (SINGLE BUTTON) ACTIV A TION 3. 24 V AC Radio Receiver Power Only (250 ma. maximum) 4. SINGLE BUTTON ACTIV A TION INPUT/ OPEN LOOP LOGIC OUTPUT 5.
21 1 Motor 2 Motor 3 Neutral 4 24V AC 5 Limit 6 Spare 7 Limit 8 COM 2.8 Auxiliar y T erminal Description 2.9 Second T erminal Description 10 9 8 7 6 5 4 3 2 1 1. OPEN DIRECTION NON-CONT ACT SENSOR (Photocell) Stops gate movement in the open cycle. Gate resumes normal operation when the input (obstruction) is cleared.
22 6500-065-K-7-08 3.1 Circuit Board Adjustments SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete.
23 3.2 DIP-Switch Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect.
24 6500-065-K-7-08 Safety Protection 13 14 12 11 10 9 8 7 6 5 4 3 2 1 3.4 Inherent Entrapment Sensing Adjustment 3.3 Limit Sensing System Adjustment This vehicular gate operator is equipped with an inherent adjustable reversing sensor (T ype A) that is used as the primary entrapment sensing system.
25 6500-065-K-7-08 SECTION 4 - OPERA TING INSTRUCTIONS WARNING - T o reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate.
26 6500-065-K-7-08 4.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. T o determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator .
27 6500-065-K-7-08 4.3 Manual Gate Operation This operator is equipped with a manual release system that will allow the gate to be pushed open in the event of a power outage or equipment failure. NEVER remove the hub from the operator after manually releasing it.
• Be sure that power is removed or shut-off prior to placing the gate operator in manual operation. Manual Release Remove release tool and place where shown. Release hub. Gate can now be manually operated. B C Unlock the cover and rotate sliding door .
29 6500-065-K-7-08 SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS The optional convenience open system installed in your vehicular gate operator is designed as a convenience enhancement only . It is not designed or intended to provide continuous gate operation during a power outage.
30 6500-065-K-7-08 DC MOTOR NEGA TIVE OUTPUT DC MOTOR POSITIVE OUTPUT BA TTERY NEGA TIVE INPUT BA TTERY POSITIVE INPUT 24 V AC COMMON 24 V AC INPUT ACTIV A TION OUTPUT RADIO POWER Not used.
31 6500-065-K-7-08 6.1 Maintenance SECTION 6 - MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be per formed anytime a malfunction is obser ved or suspected. High cycle usage may require more frequent service checks.
32 6500-065-K-7-08 6.2 Troubleshooting Have a good VOM meter to check voltages and continuity . A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops.
33 6500-065-K-7-08 • Check the reversing sensitivity . • Disconnect the gate from the gate operator and check that the gate swings freely without any binding. • Replace the circuit board. Gate opens a short distance, then stops and reverses. Alarm sounds for 5 minutes and then beeps once every 5 seconds.
34 6500-065-K-7-08 6.4 Accessor y Items The following accessory items are available for the model 6500 swing gate operator . Contact Sensors - For use as a secondary entrapment protection device. Miller Edge, Inc., MGO20, MGR20, MGS20 Photo Cell - Non-contact (photo-cells) sensors for use as a secondary entrapment protection device.
35 6500-065-K-7-08 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF TEST NC TIME DELA Y NO REV SENSE PRIMARY REV SENSE SECONDAR Y 1 2 3 4 5 6 7 8 9 13 .
36 6500-065-K-7-08 2340 Orange Secondary Current Sensor 2 Loops 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 – – + + 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF TEST NC TIME DELA Y NO REV.
37 6500-065-K-7-08 Secondary Current Sensor 2 Loops Model 6500 1/2 HP 230 / 460 V AC 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF TEST NC TIME DELA.
38 6500-065-K-7-08 2340 Orange – – + + Batteries 12 V 3 Amp/Hr 12 V 3 Amp/Hr 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF TEST NC TIME DELA Y N.
39 6500-065-K-7-08 Secondary Current Sensor 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF TEST NC TIME DELA Y NO REV SENSE PRIMARY REV SENSE SECONDA.
40 6500-065-K-7-08 2340 Orange 1 Loop – – + + Batteries 12 V 3 Amp/Hr 12 V 3 Amp/Hr Red Blue White 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF.
41 6500-065-K-7-08 Secondary Current Sensor 1 HP Red Blue White Ground Model 6500 1 HP 230 / 460 V AC 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 ON 2 3 4 1 ON REVERSE LOOP P2 EXIT LOOP SELF .
42 6500-065-K-7-08 2340 1 Loop Brown Secondary Current Sensor – – + + Batteries 12 V 3 Amp/Hr 12 V 3 Amp/Hr Model 6500 1 HP 230 / 460 V AC / Convenience Open 1 HP Red Blue White Ground 20 19 18 17.
43 6500-065-K-7-08 2340 Model 6500 1/2 HP Secondar y Operator Model 6500 1/2 HP Secondar y Operator/Convenience Open – – + + Magnetic Open Sensor 1/2 HP 50uf Capacitor DC Power Batteries Red Red/W.
44 6500-065-K-7-08 2340 Model 6500 1 HP Secondar y Operator Model 6500 1 HP Secondar y Operator/Convenience Open – – + + Magnetic Open Sensor 1 HP DC Power Batteries Red Red Red/White Red/White Bl.
.
6500-065-K-7-08 DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com Series 6500 Owner’ s Manual Series 6500 Vehicular Swing Ga.
Een belangrijk punt na aankoop van elk apparaat DKS 6500 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen DKS 6500 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens DKS 6500 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding DKS 6500 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over DKS 6500 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van DKS 6500 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de DKS 6500 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met DKS 6500 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.