Med- Aire 8” Alternating P ressure Mattress R eplacement System With Low Air Loss Item # 14027 ww w . drivemedical. com OPERA TOR’S MANU AL.
2 T ABLE OF CONTENT S IMPORT ANT SAFEGUARDS............................................................................................................ 3 ST A TEMENTS & SYMBOLS.......................................................................
3 IMPORT ANT S AFEGU ARDS When using electrical products, especially when childr en are pr esent, basic safety precautions should always be followed, including the following READ ALL INSTRUCTIONS BEFORE USING DANGER T o r educe the risk of electrocution: • Alwaysunplugthisproductimmediatelyafteruse.
4 Note, caution, w ar ning & danger statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operatingor maintenance procedure in order to prevent damageto or destructionof theequipmentorotherproperty .
5 INTRODUCTION This manual should be used for the initial set up of the system and for refer ence purposes. GENERAL The14027seriesisa highqualityandaffor dableair supportsur facesuitablefor mediumandhigh-risk pressur e ulcer tr eatment.
6 P A CKA GE C ONTENT Check inside the package. If any of the following items should be missing or damaged, please contact yourlocaldealerorservicecenterforreplacementimmediately . PUMP Make sure the type of pump is identical to which you pur chased.
7 PUMP The functions of the pump for the 14027 series are described below . P ower Switc h (1) The switch is at the right side of the pump. T urn ON/OFF the power , the pump will star t/stop operation. Pressure-adjust Knob (2) T urnthesoft/r mknobtosetacomfor tablepr essurelevel.
8 INS T ALLA TION Step 1 Placethemattressatlyonthebedframe. The inationtube should be towar ds the foot endso that it canbe connected to theination nozzles on the pump.
9 GROUNDING INS TRUCTIONS Thisproductshouldbegrounded.Inthe eventofan electricalshor tcircuit,gr ounding r educes therisk of electric shock by pr oviding an escape wire for the electric current.
10 OPERA TION Always read the operating instructions befor e use. GENERAL This product is designed to provide maximum comfor t to patients. Make sure that you operate this product in apr oper wayto optimizing itsvalue.
11 Alwa ys read the operating instructions before use. Please follow instructions below for detailed operating procedur e of each type. Step 1 T urn on the power . The indicator light on the power switch will come on. The pump starts to pump air into the mattress.
12 Alwa ys read the operating instructions before use. CPR FUNCTION When there is an emergency to perform CPR on the patient, pull the CPR strap at the head section of themattresstor eleasetheairquicklyfromthemattr ess.
13 In this section, we describe the procedur es to clean and decontaminate the pump. It is impor tant to follow these procedur es before using the system again. Thecleaningtaskisrequir edatleastonceaweektomaintainpersonalhygiene.
14 • Laythemattressoutatandupsidedown. • Roll from the foot end towar ds the head end; the foot-end strap can then be stretched around the rolledmattr esstopreventunr olling.
15 Thepumpdoesn’twork 1. Checkiftheplugisinsertedr mlyintotheoutlet. 2. T urn on the power switch again. • If thepower indicatoris ONand the pumpstill doesn’t work, contact your local dealer immediately .
16 SPECIFIC A TIONS SYSTEM ITEM SPECIFICA TIONS Classication ClassI;IPX0;AP/APGNO;T ypeBF Applied Part Mattress InputRating AC120V60Hz;12W ,.
17 Y our Drive brand product is warranted to be fr ee of defects in materials and workmanship for 12 months of the original consumer purchaser . This device was built to exacting standards and car efully inspected prior to shipment.
18 NO TES.
19 NO TES.
99SeaviewBoulevard Port Washington, NY 11050 Phone:516-998-4600 Fax:516-998-4601 www .drivemedical.com.
Een belangrijk punt na aankoop van elk apparaat Drive Medical Design 14027 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Drive Medical Design 14027 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Drive Medical Design 14027 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Drive Medical Design 14027 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Drive Medical Design 14027 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Drive Medical Design 14027 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Drive Medical Design 14027 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Drive Medical Design 14027 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.