1 Owner ’ s Assembly And Operating Manual Ultr a Light Plus, Semi Electric Bed Competitor Item # 15560.
2 REV3.1.23.14 1. Remove contents from carton. Assembl y Instr uctions 2. Placebothendsofthesleepsurfaceontheirsideandaligntheangewiththereceptacleasshown.
3 Assembl y Instr uctions Cont. 4. Securethesleepsurfacewiththecotterpinasshown. 5. Lockthecotterpinwiththeattachedclasp.
4 REV3.1.23.14 Assembl y Instr uctions Cont. 6. NOTE:Beforeinstallingmotor ,plughandpendantcableintomotorasshown 7.
5 Assembl y Instr uctions Cont. T her e ar e tw o methods for the installa tion of the motor Method A The motorisinstalledonthebedframewhentheframeisstanding on its side. Installation instructions can be found on pages 7-8.
6 REV3.1.23.14 Assembl y Instr uctions Cont. A2. Align the opening on the head end of the motorwiththeangeontheheadsectionof thebedandinserttheangeintothemotor compartment. Actuator Bar Flange A3.
7 A6. Once in place, replace the motor covers to secure the motor . A6. Oncethemotorisattached,laybedatandinstallheadandfootboards.Thereare2height adjustments on the head and foot board. Select the desired positions and hook the frame onto the foot board.
8 REV3.1.23.14 Assembl y Instr uctions Cont. End Method A Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions.
9 End Method A Method B Installation of the motor from underneath the frame B2. Repeat for the other side. Assembl y Instr uctions Cont. Deck Height Pins Leg Holes Upper Lower 1- High 1- Medium 1-Low B1.
10 REV3.1.23.14 Assembl y Instr uctions Cont. B4. Removethecoversfromthemotorandplaceunderthebedandalignedwiththeactuatorunderthehead section. There are labels on the motor that provide direction and placement in relation to the head section.
11 Assembl y Instr uctions Cont. B6. Once in place, replace the motor covers to secure the motor . End Method B.
12 REV3.1.23.14 Assembl y Instr uctions Cont. Oncethedesiredpositionisfound,turnthethumbscrewuntiltight. Adjustotherlegstothesameposition. 12. Adjustmenttwoisonthelegoftheheadandfootboard.
13 Assembl y Instr uctions Cont. Thechartbelowindicatestheheightadjustmentsastheyrelatetothetwoadjustmentoptions. *Rails cannot be used at this height. Deck Height (inches) Deck Height Pins Leg Hole Wheels 1 1* Lower Low No 13.
14 REV3.1.23.14 Assembl y Instr uctions Cont. 14. TheCompetitorbedcomeswithacasteraccessory(soldseparately ,model#15044SET).T oinstallthe casters,insertthestemofthecasterintothelegreceptacleasshown.
15 15. T oinstallbedrails,lifttheheadsectionandndtherailreceptaclelocatedontheframeofthebedasshown. Assembl y Instr uctions Cont. 16. Pullreceptacleoutwardandreturnheadsectiontotheatposition.
16 REV3.1.23.14 Assembl y Instr uctions Cont. 18. Insert the bed rail into the receptacle. Repeat for the other rail. NOTE: The competitor bed can be used with a free standing trapeze or a Drive Medical frame mounted trapeze (Item # 15560TRAPEZE). A trapeze cannot be mounted on the Competitor head board.
17 Driverecommendsthefollowingmaintenanceandcleaningproceduresbeconductedbetweenusers. ELECTRONICS • Checkallcontrolstomakesureallfunctionsworkproperly . • Foot control • Head control • Checkallcablesfordamagedorfrayedwires.
18 REV3.1.23.14 99 Seaview Boule v ar d P ort W ashington, NY 11050 Phone: 516-998-4 600 T oll F ree: 8 77 .224 . 09 46 F ax: 516. 998.460 1 ww w .driv emedical.
Een belangrijk punt na aankoop van elk apparaat Drive Medical Design 15560 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Drive Medical Design 15560 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Drive Medical Design 15560 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Drive Medical Design 15560 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Drive Medical Design 15560 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Drive Medical Design 15560 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Drive Medical Design 15560 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Drive Medical Design 15560 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.