www.eaton.com Net w ork Management Card User manual Network Management Ca rd – User Manual 34003991EN/EB Page 1/118.
Network Management Ca rd – User Manual 34003991EN/EB Page 2/118 Contents 1 EATON NET WORK SOLUTION 5 1.1 G ENERAL P RESENTATION 5 1.1.1 Connecting the U PS to the Ethernet net work 6 1.1.2 Protection of the co mputers/servers 6 1.1.3 Supervision of the UP Ss over the network 7 1.
Network Management Ca rd – User Manual 34003991EN/EB Page 3/118 4.3.1 Email Notification 43 4.3.2 E-mail Message Set tings 45 4.4 C ONFIGURATION 47 4.4.1 Network settings 48 4.4.2 System 50 4.4.3 Notified Applications 52 4.4.4 Central shutdo wn configuration 54 4.
Network Management Ca rd – User Manual 34003991EN/EB Page 4/118 7.4 JBUS TABLE 91 7.4.1 Data for Pulsar 700 / 1000 / 1500 91 7.4.2 Data for Pulsar M 2200 / 3000 93 7.4.3 Data for Pulsar MX 4000 / 5000 / 1 0000 and EX 5 / 7 / 11 RT 95 7.4.4 Data for Pulsar MX frame 15 / 20 97 7.
Network Management Ca rd – User Manual 34003991EN/EB Page 5/118 1 EATON Netw o rk Solution 1.1 General Presentation EATON Network Solution : - Provides informat ion on events concerning the supply o.
Network Management Ca rd – User Manual 34003991EN/EB Page 6/118 1.1.1 Connecting the UPS to the Ethernet network This function can be performed t hrough network Cards inserted in the U PS (Network Management Card). A lso a software "agent" running on a nearby PC that is called the Network Management Proxy can be used.
Network Management Ca rd – User Manual 34003991EN/EB Page 7/118 1.1.3 Supervision of the UPSs over the netw ork Depending on y our needs, y ou can either use: Your Internet browser to monitor eac h .
Network Management Ca rd – User Manual 34003991EN/EB Page 8/118 1.1.4.1 How to connect UPS / agent / network: Insert the optional card in the UPS and connect the UP S to the computer network. Start the UPS, then the computers. 1.1.4.2 Setting up the protec tion: Set up the Network Management Card (se e user manual).
Network Management Ca rd – User Manual 34003991EN/EB Page 9/118 Network Management Ca rds are com patible with the "Enterprise Power Management" supervisi on syst em, with the MGE Office Protect ion Syste ms network protection sy stem and with Po werware Netwatch.
Network Management Ca rd – User Manual 34003991EN/EB Page 10/118 1.3 Technical data 1.3.1 Hardware characteristics Dimensions Dimensions (L x l x H) 132 x 66 x 42 mm Weight (gr) 70 g Storage Storage.
Network Management Ca rd – User Manual 34003991EN/EB Page 11/118 1.3.4 Administration Up to 35 workstations( in TCP co nnected mode) or u p to 100(in UDP broa dcasted mode) prote cted by Network Shutdown Modules - Central or l ocal configuration . Up to 5 browsers connected at t he same time (3 in SS L).
Network Management Ca rd – User Manual 34003991EN/EB Page 12/118 ◗ Recording of events and measurements in the card log ◗ Possibility of shutting down the installation in the event of a thres ho.
Network Management Ca rd – User Manual 34003991EN/EB Page 13/118 1.3.8 Default parameters Function Parameter Default value Possible value Network IP address 166.99.16.16 Network IP address Subnet mask 255.255.0.0 Network IP address Gateway A ddress 0.
Network Management Ca rd – User Manual 34003991EN/EB Page 14/118 2 Installation 2.1 Unpacking and check on contents The installation kit co ntents: ◗ A Network Management Card (661 02) ◗ A serial communication cable for configura tion (34003918 ) ◗ Installation manual (34003905) 2.
Network Management Ca rd – User Manual 34003991EN/EB Page 15/118 Ethernet port LED Colour A ctivit y Description ACT Green ◗ Off ◗ Card not connected t o the netw ork. ◗ On ◗ Card connected to the network but without activity ◗ Flashing ◗ Port is active in rece iving / transmission 100M Orange ◗ Off ◗ Port operating at 10 Mbits/s.
Network Management Ca rd – User Manual 34003991EN/EB Page 16/118 2.4 Sensor installation (option) The Environment sensor is available as a n option on the Net work Management Card and is availa ble from MGE Office Protection Sy stems (reference 668 46).
Network Management Ca rd – User Manual 34003991EN/EB Page 17/118 3 Configuration 3.1 Configure IP parameters Once the card has start ed: Connect one end of the cable (3400 3918) to the Service port . If the environment sensor was prev iously connected, the card must be restart ed in order to acce ss the configurat ion menu.
Network Management Ca rd – User Manual 34003991EN/EB Page 18/118 3.1.1 Your network is equipped with a DHCP serv er The card is configure d by default with this service activat ed.
Network Management Ca rd – User Manual 34003991EN/EB Page 19/118 3.1.2 Your network is not equipped with a DHCP server In the main menu enter 2, then 2 again .
Network Management Ca rd – User Manual 34003991EN/EB Page 20/118 4 Supervision and a dministration by browser ◗ On a computer equ ipped with a Web browser (Internet Explorer, FireF ox or Netscape reco mmended), enter the address initialised previously in the Installation chapter (e.
Network Management Ca rd – User Manual 34003991EN/EB Page 21/118 4.2 UPS 4.2.1 UPS properties page This page is automatica lly ref reshed every 10 sec onds. From this page, acces s to the ma in UPS information is ava ilable thanks to the combo b ox (see scree n copy below).
Network Management Ca rd – User Manual 34003991EN/EB Page 22/118 4.2.1.1 "UPS" zone: general information on the UPS. Indication of the picture and generic na me of the UPS range Computer room: Custo mised name of y our sy stem. You can change th is name on th e "System" page.
Network Management Ca rd – User Manual 34003991EN/EB Page 23/118 UPS without auto matic by pass Note: In case of loss of commu nication with the UPS , all the ele ments of the sy noptic are grey .
Network Management Ca rd – User Manual 34003991EN/EB Page 24/118 ◗ Battery : Remaining capacity > 50% Remaining capacity < 50% Battery to be checked (battery test result) ◗ Battery Output .
Network Management Ca rd – User Manual 34003991EN/EB Page 25/118 ◗ A C A utomatic By pass Flow : Energy flow present No energy flow ◗ A C A utomatic By pass Status : Powered Not powered Internal.
Network Management Ca rd – User Manual 34003991EN/EB Page 26/118 ◗ UPS measurements : ◗ Boxes showing measure ments appear when sy noptic elements are hovered by the pointer. See exa mple below. These measurements are available for AC to DC converte r, Battery , DC to AC converter and a utomatic by pass.
Network Management Ca rd – User Manual 34003991EN/EB Page 27/118 4.2.1.2 "UPS status" zone: Es sential informat ion ◗ "Active sources": (a vailable on paralle l or modular UPS) x UPS + y UPS redundant : x indicates the m inimal number of UPS necessary to power the load, y indicates the number of UPS in redu ndancy .
Network Management Ca rd – User Manual 34003991EN/EB Page 28/118 4.2.1.3 Viewing the modules ◗ Click on "UPS Modu les" scroll lis t to view the information about the UPS mo dules.
Network Management Ca rd – User Manual 34003991EN/EB Page 29/118 ◗ The Status can take the next forms: or when the module is working proper ly with no alarm . when the module ha s at least one alar m (level Warning) active. when the module ha s at least one alar m (level Critical) act ive.
Network Management Ca rd – User Manual 34003991EN/EB Page 30/118 4.2.1.4 Viewing the alarms Click on "A larm Table" scroll list to vie w the list of current alarms.
Network Management Ca rd – User Manual 34003991EN/EB Page 31/118 ◗ A larm table for modular UPS.
Network Management Ca rd – User Manual 34003991EN/EB Page 32/118 4.2.1.5 Viewing the “Abou t your UPS” window Click on "A bout your UPS" scroll list to v iew the informati on about the U PS and the card.
Network Management Ca rd – User Manual 34003991EN/EB Page 33/118 4.2.2 On-line help On-line contextual he lp in Engli sh is available at the top of each page by clicking on the He lp link, which is a lway s located on the top r ight corner. T he navigation menu of the on-line he lp is identical to that of the card's pa ges.
Network Management Ca rd – User Manual 34003991EN/EB Page 34/118 4.2.3 UPS control Click on the "UPS C ontrol" section in the menu The parameters of t his menu can on ly be modified aft er entering the "Login " and "Pass word".
Network Management Ca rd – User Manual 34003991EN/EB Page 35/118 UPS configuration may prev ent the shutdown and resta rt comma nds from being properly run. Read the UP S user manual for more information. This page enables tr iggering of startup and shutdo wn sequence s for the UPS main output and cont rolled outlets.
Network Management Ca rd – User Manual 34003991EN/EB Page 36/118 "Immediate On" : A sequence to switch on output p ower is launc hed immediately .
Network Management Ca rd – User Manual 34003991EN/EB Page 37/118 4.2.4 UPS weekly schedule programming Click on the "Weekly schedule" section of the menu . UPS configuration may prev ent the shutdown and resta rt comma nds from being properly run.
Network Management Ca rd – User Manual 34003991EN/EB Page 38/118 4.2.5 Shutdown parameters This page enables v iewing and configurat ion of UPS operat ing parameters in batt ery mode and for power restoration. Click on the "Shutdo wn paramete rs" section in the men u to see the list of para meters.
Network Management Ca rd – User Manual 34003991EN/EB Page 39/118 For the main outlet ( "Master" by def ault) The first shutdow n criteria initiates the re start of the shutdow n sequence .
Network Management Ca rd – User Manual 34003991EN/EB Page 40/118 4.2.6 Measurements Click on " Meas urements " in the menu ◗ The next windo w shows the me asurements for a mon o phases UPS. The following meas urements are saved and time-sta mped (env.
Network Management Ca rd – User Manual 34003991EN/EB Page 41/118 4.2.7 Event log ◗ Click on "Event Log ". in the menu ◗ "Save log" enables a ll saved values to be opened or saved in CSV format . (compatible with Excel ty pe spreadsheets) ◗ "Clear log" enables de letion of all records.
Network Management Ca rd – User Manual 34003991EN/EB Page 42/118 4.2.8 System log ◗ Click on "System l og". in the m enu ◗ "Save log" enables a ll saved values to be opened or saved in CSV format . (compatible with Excel ty pe spreadsheets) ◗ "Clear log" enables de letion of all records.
Network Management Ca rd – User Manual 34003991EN/EB Page 43/118 4.3 Notification 4.3.1 Email Notification The card offers the possibility of redirecting UPS alarms to an e-mail server. The format of thes e e-mails is compatible with mobi le telephone transf er sy stems using text messages (SMS) .
Network Management Ca rd – User Manual 34003991EN/EB Page 44/118 ◗ Recipient List: On the left side of t his page, up to four recipients can be configured to receive e-mails fro m the card. Each addressee has its o wn trigger event s, selected from the r ight side of the page , for which an e-m ail is sent.
Network Management Ca rd – User Manual 34003991EN/EB Page 45/118 4.3.2 E-mail Message Settings This page enables c ustomisation of the content of the messages received by recipients of e-ma ils sent by the card. Customisation is c ommon to th e four recipients that can be notified (see E-mail notificati on ).
Network Management Ca rd – User Manual 34003991EN/EB Page 46/118 The body of the e-mail sent is compos ed of: - Message text, whic h is free text . - The date and ti me of the event, as save d in the log. - URL of the card, enab ling a direct link with the card to be established.
Network Management Ca rd – User Manual 34003991EN/EB Page 47/118 4.4 Configuration The parameters of t his menu can on ly be modified aft er entering the "Login " and "Pass word". The following screen is proposed automatical ly: The default login an d password are : admin/admin Each field accepts up to 10 chara cters max.
Network Management Ca rd – User Manual 34003991EN/EB Page 48/118 4.4.1 Network settings Click on "Network" in the menu. This menu enables the administ rator to configure the network parameters of the card and a uthorisation of the remote upgrade of the embe dded sys tem.
Network Management Ca rd – User Manual 34003991EN/EB Page 49/118 If the hostname is not used, the IP address supplied by the DHCP server must be fixed to maint ain connection with the clients installed on the stations to be protected.
Network Management Ca rd – User Manual 34003991EN/EB Page 50/118 4.4.2 System Click on " System " in the menu. This menu enables the customisat ion of the information o n the UPS propert ies pages. ◗ UPS Contact: Th is text field is limited to 49 characters.
Network Management Ca rd – User Manual 34003991EN/EB Page 51/118 ◗ Factory Reset button: enables re storation of the defau lt configuration of al l the card’s para meters. TCP/IP parameters: IP addres s, subnet mask, gat eway and BootP/DH CP value are maintained if the "Keep TCP/IP parameters" option is selected.
Network Management Ca rd – User Manual 34003991EN/EB Page 52/118 4.4.3 Notified Applications Click on " Notified Appl ications " in the menu. Security : The administrator has to ente r his/her login/pass word in order to vie w this information .
Network Management Ca rd – User Manual 34003991EN/EB Page 53/118 application) or Central (coming from the card). The Central sh utdown configuration is available by clicking on the Configura tion link. ◗ Shutdown duration: the shutdown durat ion necessary to properly shutdown the computer.
Network Management Ca rd – User Manual 34003991EN/EB Page 54/118 4.4.4 Central shutdown configuration Click on "Notified A pplications" in the menu, then "Config uration".
Network Management Ca rd – User Manual 34003991EN/EB Page 55/118 4.4.5 Access control Click on " Access Control " in the menu. To access this page , the login and pass word are sy stematically requested if they have not already been entered.
Network Management Ca rd – User Manual 34003991EN/EB Page 56/118 ◗ SSL Ac cess: When selected, access to the Web interface is made in secure mo de (https). Connections with Ne twork Shutdo wn Modules stay in standard mode (s ecure TCP) SSL Security Implementation: SSL version 3.
Network Management Ca rd – User Manual 34003991EN/EB Page 57/118 4.4.6 Date and time Click on " Date and Time " in the menu. This menu enables initialisation of the da te and time of the ca rd in three differe nt way s.
Network Management Ca rd – User Manual 34003991EN/EB Page 58/118 ◗ Synchronize with NT P server: Enables co nnection with a time server, either available on the co mpany ’s internal network or on the Web.
Network Management Ca rd – User Manual 34003991EN/EB Page 59/118 4.4.7 Firmware upload Click on " Firmware Upload " in t he menu. This menu enables a new firmw are version to be uploade d To upload a ne w version of the card's firmware, select the file to be loaded using the "Browse…" butt on and click Upload.
Network Management Ca rd – User Manual 34003991EN/EB Page 60/118 4.5 Environment Sensor (option ) The environment sens or (66846) is an o ption that enables te mperature and hu midity to be measured, and indicat ion of the position of two external conta cts.
Network Management Ca rd – User Manual 34003991EN/EB Page 61/118 4.5.2 Environment Status For both measure ments, a graduated gauge proposes the following functions : The cursor indicates the current value. Two red zones to the left and rig ht represent the high a nd low thre sholds that can be set on the Envir onment Settings page.
Network Management Ca rd – User Manual 34003991EN/EB Page 62/118 4.5.3 Environment Settings The environment sens or measures temperature, humidity and gives the stat us of the 2 contac ts (used for door, alarms or generator unit).
Network Management Ca rd – User Manual 34003991EN/EB Page 63/118 The low alarm disappe ars when the value returns above the Low threshold + Hysteres is value Input #1 and Input #2 : Enter an i dentifier correspondin g to the acquired contact (e.g.: rack door, air condition ing, generator unit, etc.
Network Management Ca rd – User Manual 34003991EN/EB Page 64/118 4.5.4 Log The two environ ment sensor measurements : Temperature and Humidity are recorded at an interva l defined by the Environment log interv al in the System settings pa ge. By default, this peri od is 300 seconds.
Network Management Ca rd – User Manual 34003991EN/EB Page 65/118 5 Server protection 5.1 Set-up of the shutdown pa rameters The protection appl ication : Network Shutdown Module or Netwatc h, on pro.
Network Management Ca rd – User Manual 34003991EN/EB Page 66/118 Start of the shutdo wn sequence Delay before shutdown Utility failure Remaining autono my 100% Shutdown after : If remaining time und er UPS Shut off Card param eters UPS parameters Shutdown duration Battery capacity 0% Shutdown if remainig capacity under t 5.
Network Management Ca rd – User Manual 34003991EN/EB Page 67/118 5.1.1.3 Shutdown when backu p time is less than When the Network Management Card detect s that the percenta ge of backup ti me remaining is less than the value set, the shutdown seq uence is started.
Network Management Ca rd – User Manual 34003991EN/EB Page 68/118 5.1.2 Controlled outlets Certain UPS models are equipped with controlled outlets (generally 2) which are alway s dependant on the U PS's main outlet. Shutdown of the mai n outlet syst ematically causes shutdown of the progra mmable outlets.
Network Management Ca rd – User Manual 34003991EN/EB Page 69/118 5.1.3.2 Sequential startup It is possible to de lay outlet power-on to reduce inrus h currents on startup or to sequence the startup of seve ral devices. Controlled outlet start up after a given t ime is based on start up of the main outlet.
Network Management Ca rd – User Manual 34003991EN/EB Page 70/118 Shutdown duration Start shutdown main output Utility failure Utility Battery capa city under : NSM 2 on output 1 NSM 1 on main output Main output Utility restor e Start shutdown output 1 Output 1 Shutdown duration output 1 Battery capacity under : (output 1) 5.
Network Management Ca rd – User Manual 34003991EN/EB Page 71/118 5.3 Shutdown management with 2 NMC bo ards Certain UPS can have 2 NMC boa rds in order to: ◗ Increase the nu mber of protected serv ers, ◗ Protect 2 groups of serv er connect ed to different net works physically separated.
Network Management Ca rd – User Manual 34003991EN/EB Page 72/118 6 Configuration via R S232 ◗ Use the cord supplie d with the c ard. ◗ Connect the card to a computer equipped with a hy perterminal ty pe emulator. The seria l link must be set at 96 00 baud, 8 bits, no parity , 1 stop bit , and without flo w control.
Network Management Ca rd – User Manual 34003991EN/EB Page 73/118 6.1 Choice 1: Restart / Reset Use this function to rest art the c ard; two choices are possible 1 : Hardware Reset: E quivalent to a restar t of the electrica l power supply . 2 : Restart application : Restarts only the application part.
Network Management Ca rd – User Manual 34003991EN/EB Page 74/118 6.2.2 Choice 2: Modify Network settings Enables the modificati on of network para meters For each of the fol lowing questions, y ou can press <Ret urn> to select the value shown in braces, or you can ente r a new value.
Network Management Ca rd – User Manual 34003991EN/EB Page 75/118 6.3 Choice 3: Lost password / Set Login Password to De fault In the even the login or password is lost , choice 3 enab les the return.
Network Management Ca rd – User Manual 34003991EN/EB Page 76/118 6.4 Choice 4: Return to Default Configuration Enables restoratio n of the default configurat ion of all the card’s parameters -----.
Network Management Ca rd – User Manual 34003991EN/EB Page 77/118 7 Industrial Network Management Card (INMC op tion) 7.1 Presentation 7.1.1 Overview 7.1.2 Functions The Industrial Net work Manage ment Card (INMC) prov ides the s ame functions than the NMC card describe d in the previous section of th is docume nt.
Network Management Ca rd – User Manual 34003991EN/EB Page 78/118 7.1.3 Technical characteristics Functions Parameters Default values Possible values JBUS/MODBUS communication - Baud rate - Parity - .
Network Management Ca rd – User Manual 34003991EN/EB Page 79/118 7.2 Installation 7.2.1 RS232 link configuration and c onnection Set the SA2 switche s like below: The next figure sho ws the details .
Network Management Ca rd – User Manual 34003991EN/EB Page 80/118 7.2.2 RS485 link configuration and c onnection 7.2.2.1 RS485 connection The EIA RS485 link, 2 wires or 4 wires, must be polarized at a unique point of the link and must be adapted at b oth ends for a good worki ng.
Network Management Ca rd – User Manual 34003991EN/EB Page 81/118 The settings of the RS485 link are made through the SA 1 switches: SA1 description: 1: reserved 2: reserved 3: link termination betwe.
Network Management Ca rd – User Manual 34003991EN/EB Page 82/118 7.2.2.2 RS485 link configura tion for 2 wires conn exion Set the SA2 switche s like below to set the RS485 mode: Set the SA1 switche .
Network Management Ca rd – User Manual 34003991EN/EB Page 83/118 Set the SA1 switche s to select t he two wires configura tion with te rmination: The next figure gives a ty pical bus structure in th.
Network Management Ca rd – User Manual 34003991EN/EB Page 84/118 7.2.2.3 RS485 link configura tion for 4 wires conn exion Set the SA2 switche s like below: Set the SA1 switche s to select t he four .
Network Management Ca rd – User Manual 34003991EN/EB Page 85/118 Set the SA1 switche s to select t he four wires configurat ion with termi nation: The next figure gives a ty pical bus structure in t.
Network Management Ca rd – User Manual 34003991EN/EB Page 86/118 7.2.3 Configuration of the JBUS/MODBUS communication parameters ◗ Use the cord supplie d with the c ard. ◗ Connect the card to a computer equipped with a Hy per terminal ty pe emulator.
Network Management Ca rd – User Manual 34003991EN/EB Page 87/118 ◗ The next menu appears : ----------- ------------------------- -------------------------- --------------- EATON NETWORK MA NAGEMEN.
Network Management Ca rd – User Manual 34003991EN/EB Page 88/118 Setting Jbus config uration : Set Slave number : 0x7 Set the Baud Rate [1: 38400, 2: 1 9200, 3: 9600, 4: 4800 , 5: 2400, 6: 1200] :3 .
Network Management Ca rd – User Manual 34003991EN/EB Page 89/118 7.2.3.6 Choice 6: Display Jbus frames Enables the display of the Jbus f rames: Recv : 01 01 00 00 00 64 3d e1 Send : 01 81 02 c1 91 Recv : 01 03 00 62 00 64 e5 ff Send : 01 03 c8 00 00 00 00 00 00 00 00 00 00 00 00 00 .
Network Management Ca rd – User Manual 34003991EN/EB Page 90/118 7.3 Additional Web pages The INMC card Jbus parameters could be set through the next page:.
Network Management Ca rd – User Manual 34003991EN/EB Page 91/118 7.4 JBUS table 7.4.1 Data for Pulsar 700 / 1000 / 1500 7.4.1.1 Status table Status description Status to 0 Status to 1 Word (hex) Bit.
Network Management Ca rd – User Manual 34003991EN/EB Page 92/118 7.4.1.2 Measurements tab le Description of the physical quantity Word (hex) Unit I output 109 A U output 1 24 V U battery 12D V Outpu.
Network Management Ca rd – User Manual 34003991EN/EB Page 93/118 7.4.2 Data for Pulsar M 2200 / 3000 7.4.2.1 Status table Status description Status to 0 Status to 1 Word (hex) Bit Load protected no .
Network Management Ca rd – User Manual 34003991EN/EB Page 94/118 7.4.2.2 Measurements tab le Description of the physical quantity Word (hex) Unit I mains 2 106 A I output 109 A U mains 2 11E V U out.
Network Management Ca rd – User Manual 34003991EN/EB Page 95/118 7.4.3 Data for Pulsar MX 4000 / 5000 / 10000 and EX 5 / 7 / 11 RT 7.4.3.1 Status table Status description Status to 0 Status to 1 Wor.
Network Management Ca rd – User Manual 34003991EN/EB Page 96/118 7.4.3.2 Measurements tab le Description of the physical quantity Word (hex) Unit I mains 1 10 0 A I mains 2 10 6 A I output 109 A I b.
Network Management Ca rd – User Manual 34003991EN/EB Page 97/118 7.4.4 Data for Pulsar MX frame 15 / 20 7.4.4.1 Status table Status description Status to 0 Stat us to 1 W ord (hex) Bit Load protecte.
Network Management Ca rd – User Manual 34003991EN/EB Page 98/118 7.4.4.2 Modular fault table Description du Status Status to 0 Status to 1 Word (hex) Bit General alarm A bsent Present 61 0 Fan failu.
Network Management Ca rd – User Manual 34003991EN/EB Page 99/118 Description du Status Status to 0 Status to 1 Word (hex) Bit General alarm A bsent Present 65 0 Fan failure A bsent Present 65 1 Inte.
Network Management Ca rd – User Manual 34003991EN/EB Page 100/118 7.4.4.3 Measurements tab le Description of the physical quantity Word (hex) Unit I1 (I phase 1) mains 1 100 A I2 (I phase 2) mains 1.
Network Management Ca rd – User Manual 34003991EN/EB Page 101/118 Description of the physical quantity Word (hex) Unit U mains 1 (phase 1) 150 V U mains 1 (phase 2) 151 V U mains 1 (phase 3) 152 V N.
Network Management Ca rd – User Manual 34003991EN/EB Page 102/118 7.4.5 Sensor data 7.4.5.1 Status table Status description Status to 0 Status to 1 Word (hex) Bit Input 1 alarm no y es 45 5 Input 2 .
Network Management Ca rd – User Manual 34003991EN/EB Page 103/118 7.4.5.2 Measurements tab le Description of the physical quantity Word (hex) Unit Temperature measure 180 ° C / ° F Maximum tempera.
Network Management Ca rd – User Manual 34003991EN/EB Page 104/118 7.4.5.3 Read of the personal ization table Description Wor d (hex) Uni t High threshold te mperature (° C) 32C 0 Low threshold tem .
Network Management Ca rd – User Manual 34003991EN/EB Page 105/118 7.4.6 Other data Information descript ion Word (hex) Example Manufacturer name 1A0 « MGE Office Protecti on Systems » Product name.
Network Management Ca rd – User Manual 34003991EN/EB Page 106/118 8 Append ices 8.1 Tables of alarms and events 8.1.1 Table of alarms List of time dated alarms Alarm on A larm o ff Battery fuse blow.
Network Management Ca rd – User Manual 34003991EN/EB Page 107/118 Inverter overload I nverter l oad OK Inverter over temperature Inverter tempera ture OK Inverter short circu it Inverter OK Inverter.
Network Management Ca rd – User Manual 34003991EN/EB Page 108/118 If the UPS is modular UPS, for each modu le: Battery fuse blow n Battery fuse OK No Battery Battery prese nt Battery temperature fau.
Network Management Ca rd – User Manual 34003991EN/EB Page 109/118 Positive DC bus too low Positive DC bus OK Output switch (Q5N) open Output switch (Q5N) closed Normal AC NOK Normal A C OK UPS on ba.
Network Management Ca rd – User Manual 34003991EN/EB Page 110/118 Inverter fault Inverter OK Inverter overload Inverter load OK Inverter overtemperat ure Inverter temperature OK Inverter short circu.
Network Management Ca rd – User Manual 34003991EN/EB Page 111/118 8.1.3 Table of system alarms Network Management Ca rd startup Send test mail SUCC ESS Send test mail ERROR Send mail to <rec ipie.
Network Management Ca rd – User Manual 34003991EN/EB Page 112/118 8.2 SNMP objects 8.2.1 MGE MIB The NMC card imple ment reduce MGE Office Protecti on Systems MIB, with the objects be llow managed. The entire MIB descr iption is availab le on www.mgeops .
Network Management Ca rd – User Manual 34003991EN/EB Page 113/118 mgoutputFrequency _1 deciHz {7,2,1,3,1,0} mgoutputFrequency _2 deciHz {7,2,1,3,2,0} mgoutputFrequency _3 deciHz {7,2,1,3,3,0} mgoutp.
Network Management Ca rd – User Manual 34003991EN/EB Page 114/118 If the Environment Sensor is det ected , the following information are managed. upsmgEnvironA mbientTemp 0.
Network Management Ca rd – User Manual 34003991EN/EB Page 115/118 8.2.2 Table des TRAPS : (1.3.6.1.4.1.705.1.11 ) SNMP traps are sent when alarms ap pears and desappears .
Network Management Ca rd – User Manual 34003991EN/EB Page 116/118 - upsEnvironment Input1Open Trap 62 Level 2 - upsEnvironment Input2Open Trap 64 Level 2 - upsEnvironment Input2Closed Trap 63 Level 2 The level is used to se lect traps to be sent to the supervis or.
Network Management Ca rd – User Manual 34003991EN/EB Page 117/118 9 Glossary Bootp: Protocol based on UD P used to allocate an IP address corres ponding to an Ethernet card d uring the startup phase .
Network Management Ca rd – User Manual 34003991EN/EB Page 118/118 NMS NET WORK MANA GEMENT STATION (SNMP) The dedicated PC or workstation is used on the company ’s networks to adm inistrate all device s connected to the network. Data are tra nsmitted using the SN MP protocol.
Een belangrijk punt na aankoop van elk apparaat Eaton 34003991EN/EB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Eaton 34003991EN/EB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Eaton 34003991EN/EB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Eaton 34003991EN/EB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Eaton 34003991EN/EB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Eaton 34003991EN/EB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Eaton 34003991EN/EB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Eaton 34003991EN/EB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.