POWER BLOWER Operator's Manual MODEL T ype 1E PB-2100 Serial Number 001001 & Up W ARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood for proper and safe operation.
2 W ARNING DANGER Read rules for safe operation and instructions carefully. ECHO provides this Operator's Manual which must be read and understood for proper and safe operation.
3 P OWER B LOWER O PERA TOR ' S M ANUAL Throughout this manual and on the product itself, you will find safety alerts and helpful, information messages preceded by symbols or key words. The following is an explanation of those symbols and key words and what they mean to you.
4.
5 P OWER B LOWER O PERA TOR ' S M ANUAL Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Hot Surface Carburetor adjustment - Idle speed Carburetor.
6 After Refueling; • Wipe any spilled fuel from the unit. • Move at lease 3M (10 ft.) from refueling location before starting the engine. After use; • DO NOT store a unit with fuel in its tank. Leaks can occur. Return unused fuel to an approved fuel storage container.
7 P OWER B LOWER O PERA TOR ' S M ANUAL Proper Clothing -- Wear snug fitting, durable clothing. • Pants should have long legs, shirts with long sleeves. • DO NOT WEAR SHORTS, • DO NOT WEAR TIES, SCARVES, JEWELRY. Wear sturdy work shoes or boots with non-skid soles; • DO NOT WEAR OPEN TOED SHOES, • DO NOT OPERATE UNIT BAREFOOTED.
8 Noise Control • Follow local noise regulations on sound levels and hours of operations. Use only during appropriate hours. • Never use a higher speed setting then necessary to perform a task. The higher the engine speed the louder the blower noise.
9 P OWER B LOWER O PERA TOR ' S M ANUAL D ESCRIPTION After opening the carton, check for damage. Immediately notify your retailer or ECHO Dealer of damaged or missing parts. Use the contents list to check for missing parts. EMISSION CONTROL The emission control system for this engine is EM (Engine Modifica- tion).
10 1. STOP SWITCH - "SLIDE SWITCH" mounted on top of handle. Push forward to start and run . Slide back to stop. 2. THROTTLE TRIGGER - Spring loaded to return to idle when released. During acceleration, press trigger gradually for best operating technique.
11 P OWER B LOWER O PERA TOR ' S M ANUAL S PECIFICA TIONS Specifications, descriptions and illustrative material in this literature are as accurate as known at the time of publication, but are subject to change without notice. Illustrations may include optional equipment and accessories, and may not include all standard equipment.
12 A SSEMBL Y W ARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. INST ALL BLOWER PIPES 1 . Align grooves in straight pipe with pegs on blower housing and slide pipe onto housing.
13 P OWER B LOWER O PERA TOR ' S M ANUAL Handling Fuel -- W ARNING DANGER Fuel is VERY flammable. Use extreme care when mixing, storing or handling or serious personal injury may result. • Use an approved fuel container. • DO NOT smoke near fuel.
14 O PERA TION W ARNING DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions which can cause serious injury or death. • Provide all operators of this equipment with the Operator's Manual and instructions for safe operation.
15 P OWER B LOWER O PERA TOR ' S M ANUAL ST ARTING W ARM ENGINE 1. Stop Switch - Start/Run. Move stop switch button (A) away from the STOP position. 2. Start - Pull Rope. Lay the blower on a flat clear area and pull the starter handle (D) until the engine fires.
16 1 . Use only during appropriate hours. 2 . Make sure bevel at end of pipe faces outward. 3 . Allow the engine to warm up at a fast idle for a few minutes. 4 . Set engine speed with throttle position knob (F). NOTE The PB-2100 can be run at any speed between 2500 RPM to 7400 RPM once the engine has broken in (approximately after 3 fuel tanks).
17 P OWER B LOWER O PERA TOR ' S M ANUAL MAINTENANCE INTER V ALS IMPORTANT Time intervals shown are maximum. Actual use and your experience will determine the frequency of required maintenance. (1) Replacement will be required for Commercial use after 600 hours.
18 AIR FIL TER Level 1. Tools required: Cleaning brush, 25-50mm (1in.-2in.) medium bristle paint brush. Parts required: 90008 REPOWER AIR & FUEL FILTER KIT. 1 . Close choke (Cold Start Position). This prevents dirt from entering the carburetor throat when the air filter is removed.
19 P OWER B LOWER O PERA TOR ' S M ANUAL SP ARK PLUG Level 2. Tools Required: 3/4" Spark Plug deep socket, Feeler gauge. Preferably a wire gauge. Parts Required: Spark Plug, NGK BPM-7Y, P/N 99944500071 1 . Remove spark plug and check for fouling, worn and rounded center electrode.
20 EXHAUST SYSTEM Spark Arrestor Screen Level 2. Tools Required: Cross Head Screwdriver. 20mm (3/4in.) spark plug deep socket. Soft metal brush. Wooden carbon scraper. Parts Required: Spark arrestor screen P/N 14586240630, gasket P/N 14586642031. 1 . Remove spark plug and engine cover see "Cooling System Clean- ing " page 19.
21 P OWER B LOWER O PERA TOR ' S M ANUAL Initial Adjustment 1 . With engine off, turn HI speed screw (C) counterclockwise to stop. 2 . Turn LO speed screw (B) midway between stops. 3 . Turn idle screw (A) until tip of screw just touches throttle plate; then turn three (3) turns clockwise.
22 Probl em En gi n e - star ts h ard En gi n e - does n ot star t Cause R em edy En gin e Cr an k s Fu el at carbu ret or No f u el at carbu ret or Fu el strain er clogged Fu el l i n e clogged Carbu.
23 P OWER B LOWER O PERA TOR ' S M ANUAL S TORAGE Long T erm Storage (Over 30 Days) Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte- nance which includes the following: 1 . Store unit in a dry, dust free place, out of the reach of children.
ECHO, I NCORPORA TED 400 Oakwood Road Lake Zurich, IL 60047 ECHO Incorporated 400 Oakwood Road Lake Zurich, IL 60047 Technical Publications Orders DEALER? Call 1-800-432-ECHO 1-800-432-3246 CONSUMER SUPPORT 1-800-673-1558 8 - 5 Mon - Fri C.
SUPLEMENTO DEL MANUAL DEL OPERADOR NÚMERO DE PIEZA X7501 135101 (89861020561) P ARA LOS MODELO: PB-2100 Serie Número 898201 y Superior Utilice por favor este suplemento manual del operador al ensamb.
Een belangrijk punt na aankoop van elk apparaat Echo Type 1E PB-2100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Echo Type 1E PB-2100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Echo Type 1E PB-2100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Echo Type 1E PB-2100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Echo Type 1E PB-2100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Echo Type 1E PB-2100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Echo Type 1E PB-2100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Echo Type 1E PB-2100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.