AMC-S402 Installation and Use 6806800H60A March 2009.
© 2009 Emerson All rights reserved. Trademarks Emerson, Business-Critical Continui ty, Emerson Netw ork Power a nd the Emerson Network Power logo are trademarks and servic e marks of Emerson Electric Co. © 2009 Emerson Elect ric Co. All other product or service names are the property of their respective owners.
Contents PREF ACE ........................................................................................................................ ............... IV S AFETY S UMMARY ............................................................................
5 SPEC IFI CATI ONS ................................................................................................................. .1 5 5.1 P HYSICAL C HARACTERISTICS .................................................................................
List of Figures Figure 1. AMC-S402 Modu le Top View, Front Panel ........................................................................... 2 Figure 2. AMC-S402 Identification Labels ...................................................................
Preface Safety Summary The following general safety precautions mu st be observed during all phases of operation, service, and repa ir of this equipmen t. Failure to comp ly with these precautions or with specific warnings elsewhere in th is manual could result in personal injury or damage to the equipment.
To prevent serious inj ury or death from dangerous vo ltages, use ex treme caution when handling, testing, and adjustin g this equipment a nd its components. Flammability All Emerson PWBs (print ed wiring boards ) are manufactured with a flammability rating of 94V-0 by UL-recognized manufacturers.
About This Manu al The A MC-S402 Advanced Mezzanine Card SAS Hard Dr ive (HD) Carrier Installation and Use includes an explanation on how to configure and install the product, and also inclu des programming information.
introduce new terms. courier System output (for example, screen displays and reports), examples, and system prompts. < Enter >, < Return > or < CR > The carriage return or Enter key. CTRL The Control key. Execute control characters by pressing the CTRL key and the letter simultaneously, for example, Ctrl+D.
6806800H60A AMC-S402 Install ation and Use viii Har dware Pre p aration and Install ation Unpacking Instructions If the shipping carton is damaged upon re ceipt, request that th e carrier’s agent be present during the unpack ing and inspection of the equipment.
1 AMC -S402 O ver v i e w The AMC-S402 is an Advanc ed Mezzanine Ca rd (AMC) module whic h incorpor ates an enterprise class dual port SAS disk drive onto the module.
AMC-S402 Overview 6806800H60A AMC-S402 Installat ion and Use 2 Figure 1. AMC-S402 Module To p View, Front Panel 1.4 Part Number, Serial Number Labels At manufacturing time, identification labels are affixed to the AMC-S 402 as shown below.
6806800H60A AMC-S402 Installat ion and Use 3 AMC-S402 Overview Label 5: UL recogn ition Label Reviewed to 60950- 1, (File E31 8926) 2 1 3 4 4 0106825G 02A || || ||| || | | |||||| |||||||| |||| A M C -S 4 0 2-M-14 6 G ||| || ||| || | | |||||| |||||||| |||||||| 0.
2 AMC -S402 Installa tion This chapter contains the procedur es for installing and removing the AMC-S402 A MC module. 2.1 Installation and Removal of the AMC-S402 Module The AMC-S402 AMC Module can be ins talled into an ATCA shelf (chassis) with s lots designed to accept AMC.
AMC-S402 Installation 6806800H60A AMC-S402 Installat ion and Use 5 2.3.1 Observe ESD Precautions Emerson strongly recommends that you use an an tistatic wrist strap and a conductive foam pad when installing or upgrading a system.
AMC-S402 Installation 6806800H60A AMC-S402 Installat ion and Use 6 2.4.2 Understand Hot Swap Your AMC-S402 is electr ically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the front faceplate. This LED is under software control.
AMC-S402 Installation 6806800H60A AMC-S402 Installat ion and Use 7 The use of th tion with the Blue LED. Please refer to the text ns on insertion and extraction. e Module Handle is used in co njunc and table below for more d etailed instructio ector Latch stalling the AMC Module ts .
AMC-S402 6806800H60A AMC-S402 Installat ion and Use 8 e guides, apply equal and steady 7. Power on the system, if necessary. Refer to your system manu al for instructions e system. On ce power is applied to the chassis, the s a self-test that runs for approximately 10 seconds.
3 Fu n c t i o na l D e s c r i pt i o n This chapter provides a functional descrip tio n of the major components and devic es on the AMC-S402. 3.1 Overview The AMC-S402 contains three majo r functional blocks. These are: 1. The Serial isolation mu ltiplexor (mux) circ uit 2.
Functional Description 6806800H60A AMC-S402 Installat ion and Use 10 MU X Po w e r Re g u l a t o r | | || || ||||| || |||||||||| | | ||| |||| ||| || |||||||| 80221 - 12-04- 2007MF B 6635 N TCZ010 Po w e r Re g u l a t o r MMC Figure 5. AMC-S402 Top Level Board Layout 3.
Functional Description 6806800H60A AMC-S402 Installat ion and Use 11 3.4 Power Regulator The power regulator is the part of the module that g e nerates the required power from the payload power (+12V) that is delivered to the modu le through the AMC connector.
4 Connec tor Pin A ssignme nts This chapter provides connec tor pin assignme nts for AMC-S402. This module is AMC.3 compliant and uses Ports 2 and 3 as defined in th e AMC.3 specification. 4.1 AMC-S402 Port Assignments Below are the specific ports that are us ed by the AMC-S402.
Connector Pin Assignments Table 6 A MC-S402 Modu le Edge, Pin Assignments Pin# Signal Name Pin# Signal Name 1 GND 86 GND 2 12V 87 No Connect 3 'PRSNT1_L' 88 No Connect 4 'AMC_VCC3'.
Connector Pin Assignments 6806800H60A AMC-S402 Installat ion and Use 14 Pin# Signal Name Pin# Signal Name 47 No Connect 132 No Connect 48 No Connect 133 No Connect 49 GND 134 GND 50 No Connect 135 No .
5 Specifications This chapter contains the environmenta l and mechanical specifications for the AMC-S402. The environm ental specifica tions relate t o and vary with the Hard Drive tha t the AMC-S402 is configured with. 5.1 Physical Characteris tics The AMC-S402 module boa rd is 7.
Specifications 5.2 Hard Drive Operation and Storage Specifications Table 8 Environment al Specifications , Sas Disk Drives Specification Enterprise SAS Operating (Ambient) 5 to 55ºC Disk enclosure su.
Specifications 5.3 Power Requirements The AMC-S402 shall consume no mor e than the follow ing from the system supplies under normal operating conditions. Table 9 Power Requirements Part number AMC-S402xxx Management Power (MP) 100mA +12V (spin up < 100 sec ) 1.
Specifications 6806800H60A AMC-S402 Installat ion and Use 18 Table 10 EMC Emission Compli ancy Description Description US: FCC 47 CFR Part 15 Cl ass A Yes, Class A emissions requirem ents (USA) Canada.
6 Fr o n t P a n el I n d i c a t o r s The faceplate of the AMC-S402 module h as thre e LED indicators. The figure and table that follows describes the function of each.
7 IPMI F unc tions List The AMC-S402 module employs a Module Management Controller (MMC) as specified in t he AMC.0 specificatio n. The MMC provides an Intelligent Pl atform Managemen t Interface (IPMI) which will communicate with the ATCA and MicroTCA shelf managers.
IPMI Functions List 6806800H60A AMC-S402 Installat ion and Use 21 Table 13 Example FR U Data Records Board Information AMC -S402-146G Version 1 Language Code 25 (EN-English) MFG date.
IPMI Function List 7.3 Supported IPMI Commands The MMC communicates with th e carrier controller through the local IPMB-L bus of the carrier and responds to all mandatory comma nds for AMC Module Management Controllers (as defined in the AMC Spec ific ation), as well as some optional ones.
IPMI Function List 6806800H60A AMC-S402 Installat ion and Use 23 Command IPMI/PICMG/ AMC Spec NetFn CMD MMC Req Set AMC Port State 3-27 PICMG 19h Mandatory Get AMC Port St ate 3-28 PICMG 1Ah Mandatory.
8 IPMI Firmw are Upgrade Proc edure This chapter provides the i nstruction for upgrading the IPM C (Intelligent P latform Management controller) firmware . If the AMC-S402 requires new firmware, an up grade can be performed remo tely using a LAN connection to the self manager.
IPMI Firmware Upgrade Procedure COMMAND SYNTAX EXAMPLES E XAMPLE 1. The following example shows t he command sequence for firmware upgrade of an AMC installed on a carrier: $ ipmitool -I lan -H 192.168.0.2 -T 0x82 -B 0 -t 0x74 -b 7 hpm upgrade hpm1fw.
Een belangrijk punt na aankoop van elk apparaat Emerson AMC-S402 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson AMC-S402 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson AMC-S402 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson AMC-S402 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson AMC-S402 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson AMC-S402 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson AMC-S402 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson AMC-S402 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.