Gebruiksaanwijzing /service van het product BW1 van de fabrikant Emerson
Ga naar pagina of 15
® ce c Installation and Maintenance Manual For IntelliGear Plus™ MD and BW1 V ariable Speed Drives UL is believ ed to be a registered trade name and/or trademark of Underwriters Laboratories, Inc. and is NO T owned or controlled by Emerson P o wer T ransmission.
IntelliGear Plus ™ V ariab le Speed MD Gearmotors 2 General Safety Instructions Thank y ou f or choosing an IntelliGear Plus Gear motor . • Read and f ollow all instructions carefully . • Disconnect and lock-out po wer bef ore installation and maintenance.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 3 Contents 1 General Information ................................................................................................................................ 4 1.1 General operating principle ....
IntelliGear Plus ™ V ariable Speed MD Gearmotors 4 General Information 1 - General Information 1.1 - General operating principle The IntelliGear Plus is a combination of a 3-phase induction motor and an integrated open loop v ector v ariable speed drive.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 5 1.5 - Description of cables and pr otection devices (Customer Supplied) NO TICE: When using a circuit-break er , it must be a motor circuit-break er (D cur ve). • Complywiththesizeofprotectionfuses .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 6 1.8 - Dimensions 8.52 .39 .12 6.30 5.00 Ø .344 + .007 / -.002 HOLES Ø 4.72 Ø 3.94 5.90 11 .23 3.50 1.40 5.50 Ø .280 HOLES 4 @ 90º AS SHOWN Ø 3.1500 3.1493 CA TA LOG NUMBER CBN3001BSCB524.556 CCI 109 CCI NUMBER CCI 109-G 1 Ø V oltage Po w e r Model No.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 7 2 - Installation After connection, ensure that the seals are firmly in place, and that the screws and cab le glands are water tight to ensure drive protection. Clear any condensation from the drain holes at the bottom of the motor .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 8 3.3 Wiring diagram based on standar d configuration NOTE: IF AUTO MODE RUN/STOP CONT AC T IS NO T USED, 4-20m A INPUT CONNECTOR PINS 5 & 6 MUST BE JUMPERED TO RUN IN AU TO MODE.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 9 3.4 T erminal block assignments and MD functionality 4. Commissioning W ARNING! Before s witching on the IntelliGear Plus unit, check that the electrical connections are correct, and that any mo ving par ts are mechanically guarded.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 10 5. Operator Pad Each RPD IntelliGear unit has a ke ypad on the controller lid equipped with operator elements for H-O-A selection, manual control of unit, displa y of pump speed, faults and the ability to change some f actor y set parameters .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 11 5. 1 Fault Mode T roubleshooting Guide 5.2 Additional T roubleshooting LED Pad Display Drive Status/Fault Indication Actions Required Blank Displa.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 12 5.3 Field Modifications Of P arameters The new IVD controller with k eypad allows some f actor y set parameters to be adjusted in the field. The table belo w provides the f actor y settings for each par ameter and then optional ranges f or selection of a new setting.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 13 6 - Gear Lubrication Series 3000 CbN gear ing is shipped with one of the f ollowing synthetic lubricants per the table belo w . The gear reducer has been filled to accommodate any mounting position.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 14 T ypical Maintenance Items - Bearings and Seals Rep Description Quantity 001 Housing 1 009 Output flang r ing 1 031 Output shaft 1 042 Pinion 1 0.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 15 3 2 1 5 6 4 9 8 10 11 183 184 254 7 CbN 30 (Quantity P er Unit) FRAME 56 P art # Description Qty .
Een belangrijk punt na aankoop van elk apparaat Emerson BW1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson BW1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson BW1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson BW1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson BW1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson BW1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson BW1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson BW1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.